6ES5 928-3UA21
Siemens 6ES5 928-3UA21 – S5-135U / S5-155U CPU 928A
Siemens 6ES5 928-3UA21 is a CPU 928A processor module for S5-135U and S5-155U central controllers in the SIMATIC S5 family. This S5 CPU executes the STEP 5 user program and provides 64 KB of internal user RAM, 46 KB of separate DB RAM and a single-slot design.
CPU 928A supports logic control, arithmetic processing and closed-loop control with the appropriate program. The 3UA21 version differs from the older 3UA12 in memory hardware and mechanical design. Check the complete order number, operating system version, rack arrangement and existing program when selecting a spare.
Internal RAM and Flash EPROM card
The CPU provides 64 × 1024 bytes of internal user RAM for code and data blocks. An additional 46 × 1024 bytes of DB RAM stores DB/DX data blocks when user memory is full. These areas must not be treated as one unrestricted program-code memory.
A suitable S5 memory card provides nonvolatile program storage. Siemens ST 50 lists the 6ES5 374-2KG21 Flash EPROM card for this CPU: the card has a 128 KB capacity, of which 64 KB is usable in CPU 928A. The catalogue specifies STEP 5 software V6.6 or later for programming and erasing this card.
Older 376 EPROM and 377 RAM submodules cannot be used in the 928-3UA21. Check the running CPU’s RAM and Flash card contents separately. A fitted card does not establish that later program changes have been saved to it.
STEP 5 execution and multiprocessor operation
STEP 5 programming supports cyclic, time-controlled and hardware-interrupt-driven execution. The CPU provides 2048 flag bits, 256 timers and 256 counters. Hardware-interrupt processing requires an appropriate interrupt-capable input or CP/IP module.
CPU 928A can operate in a suitable central controller as a single processor or in a multiprocessor configuration with up to four CPUs. Review coordinator settings, task allocation and programmed data exchange when working on a multiprocessor system.
PG connection and communication
The front panel has a 15-pin serial PG connection; the system manual specifies a PG transmission rate of 9600 bit/s. Select a suitable programming cable and interface converter for this connection. A matching connector shape does not establish cable compatibility.
Check communication modules and operator panel connections against the existing system protocol. CPU 928B’s second-interface options must not be assigned to the 928A-3UA21.
Rack, power supply and I/O addressing
Install the CPU in a designated CPU position of a suitable S5-135U/155U rack. The system manual specifies 5 V ±5% and a typical current of 0.5 A at 5 V. This is the backplane supply; assess the power supply against the complete rack load.
Verify digital input, digital output and analog module addresses against module settings and the PLC program. The P-area digital process image supports 1024 inputs and 1024 outputs; these are system capacities, not physical channels on the CPU. When a single-slot 3UA21 replaces an older double-width CPU, cover the unused opening with a suitable blanking plate.
Nearby order-number comparison
6ES5 928-3UA12 is the older double-width CPU 928A design. 6ES5 928-3UB11, 6ES5 928-3UB12 and 6ES5 928-3UB21 are CPU 928B options. Check memory hardware, serial interfaces and program compatibility before deciding on a replacement.
Editor’s Note
When buying a used Siemens CPU, first check the full 928-3UA21 label. Inspect the single-slot front panel, PG connector, memory-card receptacle and backplane contacts. Establish the exact version before choosing memory hardware.
Before removing a working processor, back up the program and data blocks. Save the Flash card contents separately if a card is fitted. Changes made to RAM during the machine’s service life may not be present on an older card.
Check battery and supply condition throughout the S5 system. Switch off rack power before inserting or removing the CPU, and secure a backup before battery or memory work. OVERALL RESET erases and initializes all RAM areas; diagnose the fault before using it.
Record the QVZ, ADF, ZYK and BASP indicators when the CPU stops. An unresponsive I/O module, incorrect address or cycle-time problem can also stop processing. Use PG diagnostics to establish the cause before condemning the processor.
On a multiprocessor rack, check the CPU’s assigned task and coordinator settings after replacement. Test output functions under controlled conditions; a green RUN light alone does not complete the job. Record the CPU version, card code and backup filename for the next technician.
OtomasyonAVM resources
+ 6ES5 928-3UA21 model page · Siemens S5 second-hand models · S5 memory cards · About Siemens S5.
Related topics
+ 6ES5 928-3UA12 · 6ES5 928-3UB11 · 6ES5 928-3UB12 · 6ES5 928-3UB21. These links support version comparison; they do not guarantee direct replacement compatibility.
Browse SIMATIC S5
+ SIMATIC S5 CPU models · S5 racks · S5 power supplies · S5 cables and connectors · Siemens second-hand main page.
Siemens and external references
+ Siemens S5-135U/155U System Manual, English. C79000-G8576-C199-07; section 5.5, printed pages 5-54–5-61: CPU 928-3UA21; sections 5.9 and 5.10: restrictions on older memory submodules.
+ Siemens ST 50 SIMATIC S5 catalogue, English. Printed pages 4/23–4/24: CPU 928A internal memory, single-slot installation and 374-2KG21 card selection.