6ES5 926-3KA12
Siemens 6ES5 926-3KA12 – S5-150K Central Processor Board
Siemens 6ES5 926-3KA12 is a 926 central processor board for the S5-150K in the SIMATIC S5 family. In this system, the S5 central processing unit comprises cooperating 925, 926 and 927 boards. The 926-3KA12 carries the Betrieb/Stop operating switch and Wiederanlauf restart button.
This board is used when maintaining or selecting spares for older S5-150K machines. It is one component of the central processor assembly, rather than a complete PLC or CPU set. Check its full order number, hardware revision, system memory and companion boards before replacement.
925 / 926 / 927 central processor assembly
The Siemens S5-150K spare-parts list identifies 6ES5 925-3KA12, 6ES5 926-3KA12 and 6ES5 927-3KA13 as the central boards. They are different cooperating components, not three interchangeable alternatives.
Assess the user program together with the installed 340 or 350 memory-board arrangement. Program memory capacity and RAM/EPROM configuration depend on the fitted hardware. Internal RAM capacities specified for other S5 CPUs must not be assigned to the 926-3KA12.
Betrieb/Stop and Wiederanlauf controls
Moving the switch from Betrieb to Stop stops the controller and generates BASP to inhibit the S5 peripherals. The manual states that DMA access and PG control functions remain possible in STOP; this switch position does not disconnect power.
Moving from Stop to Betrieb initiates Neustart. Operating the Wiederanlauf button during that transition selects a different restart function. Distinguish these startup modes and verify the PLC program and machine startup conditions before operating the controls.
Supply, address resources and peripherals
The Siemens technical table specifies 5 V ±5% for the 925/926/927 central board group. The rack’s external input supply and the boards’ internal supply are different levels. Check the power supply, backup battery and S5-150K chassis together.
The same central-group table lists 1024 inputs, 1024 outputs, 2048 flag bits, 128 timers and 128 counters. These are central-system address resources, not physical I/O channels fitted to the 926 board.
Compare digital input, digital output and analog module addresses with the existing project. Record the expansion hardware as well; establish whether an absent or unresponsive peripheral board is causing the fault before replacing a central board.
Jumper settings and PG connection
The manual describes 926-board jumper functions for enabling user memory, enabling system-data memory and selecting CMOS/NMOS RAM supply. Compare the installed settings with the drawing for the board revision. Do not copy jumper positions from a different board or an unverified photograph.
The S5-150K hardware diagram uses a separate PG interface board. Select the programming cable, programming software and communication hardware for the installed arrangement. Do not assume that the 926-3KA12 has the front-panel PG port found on other S5 CPUs.
Differences between nearby order numbers
6ES5 926-3SA11 and 6ES5 926-3SA12 are different 926 versions associated with S5-150S/U systems; 6ES5 926-5AA12 belongs to the S5-150A arrangement. The 3KA12, 3SA and 5AA suffixes identify different hardware. Mechanical similarity does not establish operating-system or memory compatibility.
Editor’s Note
When buying a used Siemens board, first check the full 926-3KA12 label. Record the 925 and 927 board codes too. On a system of this age, assess the complete central assembly before deciding which component needs replacement.
While the machine is working, back up the program, data blocks and memory configuration. Check RAM and EPROM contents separately. Photograph the board arrangement and existing jumper settings to make reassembly easier.
Inspect the operating switch and Wiederanlauf button for mechanical damage or intermittent contact. Verify suspected faults by measurement. Repeatedly changing operating modes without understanding the startup function is not a useful diagnostic step; secure the machine’s motion conditions first.
Include supply, battery, fan and connector checks when maintaining the S5 system. The status LEDs described for the 927 board should not be expected on the 926. Correctly separating board functions makes fault diagnosis more effective.
Switch off power before replacing the board and secure a backup beforehand. Then check program access, startup behaviour and actual I/O functions under controlled conditions. Record board revisions and the backup filename for the next technician.
OtomasyonAVM resources
+ 6ES5 926-3KA12 model page · Siemens S5 second-hand models · S5 memory cards · About Siemens S5.
Related topics
+ 6ES5 925-3KA12 · 6ES5 927-3KA13 · 6ES5 926-3SA11 · 6ES5 926-3SA12 · 6ES5 926-5AA12. The 925/927 links identify companion boards; the other 926 links support version comparison. This is not a list of direct replacements.
Browse SIMATIC S5
+ SIMATIC S5 CPU models · S5 racks · S5 power supplies · S5 interface modules · Siemens second-hand main page.
Siemens and external references
+ Siemens S5-150K Central Controller Operating Instructions, German. C79000-B8500-C228-04; printed page 3: system arrangement; 7: central-group specifications; 11–12: controls and jumper functions; spare-parts list: complete order numbers.
+ Siemens System 8 Commissioning Instructions, PC section, German. Printed page 5-15, A10.82: 926-3KA12 operating/stop and Wiederanlauf functions.