6ES5 925-3KA12

Siemens 6ES5 925-3KA12 – S5-150K CPU 925 Central Processing Board

Siemens 6ES5 925-3KA12 is a CPU 925 board used in the three-board central processor assembly of the SIMATIC S5-150K. This Siemens automation board forms part of the central hardware that executes the Siemens S5 PLC program. During SIMATIC S5 servicing, assess the 925, 926 and 927 boards together; the 925 is a component of the CPU assembly.

The board carries hardware jumpers associated with system timing, Weck-Alarm and test arrangements. Field signals for machine sequencing and interlocks enter the system through digital input modules, digital output modules and analog modules. Sensor type, field voltage and output-load ratings depend on the selected I/O module.

Three-board CPU assembly and order-code differences

Siemens' S5-150K spare-parts list identifies 6ES5 925-3KA12, 6ES5 926-3KA12 and 6ES5 927-3KA13 together as central boards. Operator controls and indicators are distributed across the assembly: the Betrieb/Stop switch and Wiederanlauf button are on the 926 board, while the operating and stop indicators are on the 927 board.

6ES5 925-3SA11 and 6ES5 925-5AA12 are 925 order codes for different system arrangements. Preserve the complete 3KA12 suffix when selecting an S5-150K spare. Compare hardware revisions, companion-board codes and the machine's system software before approving substitution.

925 board jumpers and timing configuration

The manufacturer manual describes Weck-Alarm enable, time-value updating at 10 ms or 100 ms intervals, a 210 test-field connection, single-clock operation from the test field and the 10 MHz clock arrangement for the 925-3 board. These are hardware configuration options; the 10 MHz clock does not define the execution time of every program instruction.

The 10/100 ms update selection must be distinguished from the timers' overall setting range and the complete machine-program scan time. Some jumpers omitted from the function table are test points only. Record all jumper positions and socketed jumper blocks before removal, then compare them against documentation for the board revision.

CPU assembly specifications

The S5-150K manual specifies a 5 V ±5% supply and typically 6 A current consumption for the 925-3/926-3/927-3 central board assembly. The 6 A figure appears in the common specification for the three-board assembly; it must not be used as the independent consumption of one 925 board. The same table gives a weight of approximately 0.35 kg per board.

The central assembly provides address resources for 1024 inputs, 1024 outputs, 2048 flag bits, 128 timers and 128 counters. These are logical CPU resources, rather than physical terminals on the 925 board. Typical execution time for a binary instruction is 5 µs; actual program scan time depends on the instruction mix and system load.

Memory, programming and connections

User-program memory is configured through the system's 340 RAM and 350 RAM/EPROM memory boards. When examining S5 memory modules, distinguish the user program, system data and operating system. For memory models such as 6ES5 373-0AA21 and 6ES5 373-0AA41, verify the memory-board revision, capacity and address arrangement separately.

Programmer access uses a suitable S5 interface board. PG 511 options such as 6ES5 511-5AA12 and 6ES5 511-5AA14 must be checked against the programmer and board revision. Connections using an PG 675 or another suitable PG also require the correct S5 cable and connector arrangement. Do not assume that the 925 provides onboard Ethernet or a standard PC serial port.

During installation, inspect the S5 rack and chassis, rear connections, fans and power supply together. Remove and insert boards with power disconnected. A board fitting mechanically does not establish compatibility between the memory and central-board revisions.

Editor's Note

Start with the complete 925 label and the order numbers of the neighbouring 926 and 927 boards. A three-board processor needs to be assessed as an assembly, even when only one board is being replaced.

Photograph both sides before moving jumpers. Preserve the timing and clock configuration, and compare revisions before copying settings from another board.

Where programmer access is available, back up the program before replacement and record the data blocks and memory labels. Keep the user-program backup separate from operating-system information.

Include the power supply and fans in fault finding. If operation becomes unstable as the equipment warms up, inspect supply conditions and rear connections alongside the CPU boards.

Assess a spare in a suitable 150K assembly using programmer access, program comparison and controlled functional checks. The Siemens S5 maintenance information provides background; use the individual test record when evaluating a used board.

OtomasyonAVM resources

6ES5 925-3KA12 main page · Used Siemens S5 models · Siemens S5 technical information

Related topics

926-3KA12 central board · 927-3KA13 central board · 925-3SA11 · 925-5AA12

These links support system identification and order-code comparison; they do not establish direct interchangeability.

Navigation

Siemens · Siemens S5 · SIMATIC S5 · Memory modules · Interface boards · Racks and chassis

External references

Siemens S5-150K Operating Instructions – C79000-B8500-C228-04, archived manufacturer manual – German PDF
Siemens System 8 – 925-3KA12 jumper layout, page 5-15 – German PDF