6ES5 264-8MA12

Siemens 6ES5 264-8MA12 – IP 264 Electronic Cam Controller

Siemens 6ES5 264-8MA12 is the IP 264 electronic cam controller for S5-90U, S5-95U and S5-100U systems. Within the SIMATIC S5 family, it processes up to 64 cams on 16 cam tracks for one linear or rotary axis. It belongs to the S5 function module range used for position-dependent output switching.

In a press, packaging machine or transfer system, reading position is only part of the task: a valve or mechanism must operate at the correct point. When comparing S5 positioning modules, identify the required function and review the existing machine program together with its field wiring.

Encoder Input and Frequency Limits

The encoder interface accepts A/B signals and a zero pulse from an incremental encoder, using 5 V RS-422 differential line driver signals or suitable 24 V asymmetrical signals. The absolute encoder option uses SSI. The 5 V signal limit is 200 kHz: 32 m with a 5 V encoder supply, or 100 m with a 24 V supply, using shielded cable. For 24 V signals, the limits are 100 kHz at 25 m and 25 kHz at 100 m.

Check encoder supply voltage and signal level separately. Review encoder output types, S5 cables and connectors and encoder accessories against the label, pin assignment and mechanical coupling. A matching connector alone does not establish compatibility.

Digital Signals and Cam Processing

The module has 2 digital inputs and 16 digital outputs. Its digital inputs serve synchronization and braking enable. The digital outputs operate at 20–30 V DC, with a 0.3 A rating per channel and short-circuit protection; there is no galvanic isolation. All 16 outputs can carry 0.3 A simultaneously. Add output and encoder loads separately when checking the power supply; excluding those loads, typical module consumption is 120 mA at 24 V.

For a common cam program, the module cycle is 57.6 µs for 32 cams or 115.2 µs for 64 cams. Separate forward and reverse programs of 32 cams each use a 57.6 µs cycle. Dynamic dead-time compensation helps offset actuator delay as speed changes. These figures describe the module cycle, rather than the complete PLC scan.

CPU Compatibility, Installation and Addressing

With an S5-100U CPU 100, the supported version is 6ES5 100-8MA02. CPU 102 and CPU 103 are also supported; 6ES5 102-8MA02 and 6ES5 103-8MA02 are examples from those CPU families. The module occupies two physical slots. Local S5-95U/100U installations use the slot 0–7 area, with eight-byte input and output telegrams.

Address example: a starting slot of 2 gives input and output bytes 80–87 decimal, or 50H–57H. This is telegram data and should not be treated as 16 ordinary independent output bits. ET 200U operation requires separate station configuration.

Before replacement, review the CPU backup on S5 memory submodules alongside the machine's saved cam and encoder settings. Having a programmer such as the PG 615 available still calls for checking that the required software, connection and backup can actually be used.

Editor's Note

Start with a clear view of the label and connectors. Discuss burn marks, corrosion, bent pins or strained connections before buying; a clean housing alone does not establish that the module works.

When replacing an encoder, look beyond its pulse count. Its operating principle, supply, output circuit, direction and coupling all matter. For a used encoder, request a readable label photograph and, where possible, an actual signal test.

The IP 264 loses its RAM data when power is removed. Save the cam table and parameters before removal. Do not assume that fitting another module restores the machine settings; check that the saved data can be loaded again.

Behaviour on CPU STOP is configurable: cam processing can continue. During maintenance, do not assume that putting the CPU in STOP removes the cam outputs; establish the machine's safe stop according to its electrical design.

For any sensor candidate, including Derell encoders, compare the electrical and mechanical specifications individually. Choose by those details rather than brand or housing similarity, then check direction, reference and cam transitions at low speed.

OtomasyonAVM Resources

6ES5 264-8MA12 main page · Used Siemens S5 models · S5-90U PDF files. The family documents support system review; the detailed IP 264 manual is linked below.

Related Topics and Modules

IP 263 – 6ES5 263-8MA11 · IP 266 – 6ES5 266-8MA11 · IP 267 – 6ES5 267-8MA11 · IP 265 – 6ES5 265-8MA01 · Derell encoder options. These links support function or component comparisons; they do not establish direct interchangeability.

Used Siemens equipment · SIMATIC S5 · S5 function modules · About Siemens S5

External References

Siemens IP 264 Equipment Manual – 6ES5 998-5SL21 (English) · S5-100U system manual, Section 15.9 (English) · S5-90U/95U system manual, Section 16.9 (English) · Siemens ST 50/1998, IP 264 (English)