Siemens 6ES5 710-0AB21 is an empty housing with six module positions for the S5-010W. Siemens lists it as “Leergehäuse mit 6 Einbauplätzen.” Overall dimensions are 260 × 270 × 177 mm (width × height × depth), with an approximate empty-housing weight of 3.2 kg. Within the SIMATIC S5 family, it supports and locates the appropriate boards of the S5 control system.

Six positions do not mean six I/O modules. The CPU and other required functions form part of the arrangement. When selecting S5 racks and housings, distinguish the total number of positions from the available peripheral-module capacity.

Board arrangement and S5-010W construction

The S5-010W instructions describe a 160 × 250 mm PCB format and a 20-way system bus secured to the rear of the housing. Although listed among S5 supporting hardware, this housing must be populated according to the S5-010W architecture. The S5 family name alone does not establish module compatibility.

The standard six-position drawing shows CPU, I/T, Q, RB, I/T, Q. I/T identifies an input/timer board, Q an output board, and RB a position suitable for an interfacing board. The 6ES5 400-0AA11 input/timer module, 6ES5 410-0AA12 output module and 6ES5 410-0AA41 output module are hardware examples listed in the manufacturer’s spare-parts table for this older system.

Calculate digital input and digital output totals from the installed boards and permitted arrangement. The programming instructions assign the CPU, interfacing board and input/timer boards to specific positions. Physical insertion alone does not establish correct operation in a position.

Mounting dimensions and service clearance

The lower frame is secured to a vertical mounting surface with four M6 screws. The six-position drawing gives a horizontal mounting-hole spacing of 200 mm; the common side view gives a vertical spacing of 255 mm. Leave adequate space above and below for natural convection or cabinet ventilation.

The instructions require at least 65 mm clearance in front for inserting the front connectors. Combined with the 177 mm housing depth, these two requirements alone total 242 mm. Allow additional space for cable bends and the cabinet door. The system uses an open frame, and the manual specifies IP00 protection.

Keep the pulling force of cables and connectors off the boards and rear connections. When transferring interface hardware or communication connections, check cable restraints along with the housing mounting.

Addressing, program and replacement checks

Preserve the board sequence, address-coding jumpers and labels during replacement. Compare the PLC program addresses with the physical arrangement. Do not reinterpret addresses in a ladder diagram or function block diagram from the number of housing positions alone.

The 6ES5 500-7AA11 programming interface is also listed as a separate component. Do not assume an empty-housing order includes the CPU, program memory, programming interface or peripheral boards. Establish each item included in the delivery.

Editor’s note

For an empty housing, check straightness and mechanical condition first. Look for bent board guides, damaged threads and boards that cannot be inserted without force. Forcing a board into place is not a repair for a distorted frame.

Do more than measure the outside. Confirm that the 260 × 270 × 177 mm housing fits the cabinet and allow room for the front connectors and cables. A cable trapped by the closed door means the installation still needs attention.

Inspect the rear bus connections closely. Photograph bent contacts, cracked connections or loose mounting points. When buying used, request views of the back as well as the front.

Use controlled comparisons to establish whether a fault follows a board or remains with one position. During PLC troubleshooting, repeatedly replacing boards without checking the position and connections can add unnecessary cost.

For S5-010W maintenance, photograph the board order and jumpers before dismantling. Do not insert or remove boards while the system is live. Afterwards, check that no screws, wire fragments or other conductive debris remain inside.

When buying used Siemens equipment, remember that 3.2 kg refers to the empty housing. Record the numbers and condition of any fitted boards or connection parts separately. Request packaging that protects rear connections and board guides during transport.

OtomasyonAVM resources and PDFs

+ About Siemens S5 PLCs and S5 racks and housings: system construction and mechanical components.

+ Siemens S5 system manuals and PDF archive. Use the relevant sections of the original S5-010W documents below for this housing.

Related topics

+ 6ES5 400-0AA11 — input/timer module: a board used in S5-010W arrangements.

+ 6ES5 410-0AA12 and 6ES5 410-0AA41: digital output boards with different characteristics for this older system.

+ 6ES5 500-7AA11 — programming interface: hardware ordered separately from the empty housing.

Browse SIMATIC S5

S5 expansion products · S5 racks and housings · SIMATIC S5 · Siemens S5 PLCs · Second-hand Siemens products

Siemens and external references

+ Siemens S5-010W Operating Instructions — GWA 4NEB 807 1021-02, English. Section 1.2: PCB format and bus; printed page 9: dimensions and weight; Section 2.1: mounting; printed page 13, Figure 19: six-position housing and dimensions.

+ Siemens S5-010W and K Programming Instructions — GWA 4NEB 807 1071-02, English. Section 1.1: arrangement restrictions; Section 1.2: addressing.

+ Siemens S5-010W Betriebsanleitung — GWA 4NEB 807 1021-01a, German. Chapter 6, PDF page 26, confirms the complete 6ES5 710-0AB21 number as the six-position empty housing weighing approximately 3.2 kg.