6ES5 928-3UB12

Siemens 6ES5 928-3UB12 – CPU 928B Processor for S5-135U/155U

Siemens 6ES5 928-3UB12 is a CPU 928B processor for S5-135U/155U central controllers in the SIMATIC S5 family. This S5 CPU has 46 KB of internal DB RAM and requires a separate RAM or EPROM memory submodule of up to 64 KB for program and data blocks. Its front panel provides a fixed SI1 programming interface and an optional SI2 interface receptacle.

Assess internal DB RAM and program memory separately. Check the installed memory submodule type and capacity when purchasing. Back up current data block values together with the STEP 5 program. A project name in the programming software alone does not establish that the available file matches the machine’s latest application.

SI1 programming connection

SI1 is the fixed 15-pin PG interface, with a specified serial PG transmission rate of 9600 bit/s. Use a suitable S5 programming cable and adapter. If connection fails, check the selected port, adapter supply and cable first; a physically matching connector is insufficient.

SI2 receptacle and interface options

The installed interface submodule determines the electrical interface at SI2. A second PG connection uses the 6ES5 752-0AA53 PG submodule. An empty SI2 receptacle is not a ready-to-use second communications port. Specify the fitted submodule number separately when ordering.

Options include 6ES5 752-0AA12 TTY, 6ES5 752-0AA22 V.24 / RS-232C, 6ES5 752-0AA42 RS422-A/485 and 6ES5 752-0AA62 SINEC L1. For the relevant CPU serial-link applications, observe the RS422-A operating scope of the RS422-A/485 submodule. Its name alone does not establish unrestricted RS485 protocol support.

Protocol and partner matching

With the appropriate submodule and parameters, SI2 supports RK 512, 3964/3964R, open driver or SINEC L1 applications. SINEC L1 support is specified from version 3UB12. When reviewing the communications arrangement, record electrical interface and protocol separately. Partner speed, data format and project parameters must agree.

Power supply and physical construction

The specified supplies are 5 V ±5% and 24 V +25%/−17%. Consumption is 5 A typical at 5 V and 760 mA maximum at 24 V. Check both rails separately in the S5 power supply budget. Keep the two connected circuit boards together. Allow for the 40.64 mm front-panel width in the rack arrangement.

Replacement checks for similar 928 numbers

6ES5 928-3UB11, 6ES5 928-3UB21 and 6ES5 928-3UA12 are separate order numbers. Do not select a replacement from the 928 name alone. Compare labels, memory, the fitted SI2 submodule and the existing application. Check the replacement’s mechanical arrangement before installation.

Diagnostics and maintenance records

Record QVZ, ADF, ZYK and BASP indications together with SI1/SI2 status. During Siemens S5 maintenance, module order and program state when the fault occurs are also useful evidence. Back up the program and data before an overall reset; avoid making a reset the first diagnostic step.

Editor’s Note

When buying a used Siemens 928B, ask for more than a CPU photograph. Establish whether the memory submodule and SI2 hardware are included. Missing accessories can delay installation of an otherwise serviceable processor.

Do not read a 46 KB listing as the program capacity. DB RAM and the program submodule have separate roles. Inspect the installed memory label before treating a capacity description as complete.

For an SI2 fault, check the submodule number and partner settings first. A V.24 unit in place of TTY, or a different protocol, will not be resolved by blaming the CPU. Preserve photographs and parameters from the original connection.

Do not separate the two boards for cleaning. Remove and insert the module with power switched off. Inspect connectors, locking parts and covers before installation, and do not force a jammed module into place.

Record more than “reached RUN” after testing. Log PG connection, memory access and SI2 communication separately where used. Identify the rack and submodule used so the next technician can reproduce the test.

OtomasyonAVM resources and PDFs

+ SIMATIC S5 CPU models · S5 memory modules · Shared SIMATIC S5 PDF archive – S5-115 PDF files

Related topics

+ 6ES5 928-3UB11 · 6ES5 928-3UB21 · 6ES5 928-3UA12 · 6ES5 752-0AA53 PG submodule · 6ES5 752-0AA62 SINEC L1

Browse SIMATIC S5

+ Siemens SIMATIC S5 · S5 CPU models · S5 interface modules · S5 racks and chassis · Used Siemens equipment

Siemens and external references

+ Siemens S5-135U/155U System Manual – C79000-G8576-C199-07 (English). Section 5.4, printed pages 5-42…5-53: memory, hardware and power ratings for this CPU 928B version. Distinguish it from the 3UB21 description in Section 5.3.

+ Siemens CPU 928B/CPU 948 Communication – C79000-D8576-C277-01 (English). Serial-interface applications, protocols and submodule selection.

+ Siemens 6ES5928-3UB12 data sheet – 14 February 2020 (English). Exact order number and S5-135U/155U CPU 928B identity; externally archived copy of the Siemens document.