6ES5 885-0SA11
Siemens 6ES5 885-0SA11 – German STEP 5 Basic Software Package for PG 685
Siemens 6ES5 885-0SA11 identifies the German S5-DOS ST basic software package for the PG 685 in the SIMATIC S5 programming environment. It belongs to the software used with the PG 685 programmer. Check the full order number against the original media labels when identifying a package.
Record the SIMATIC S5 CPU order number and installed software release before maintenance. The Siemens S5 PLC guide provides background for assessing the controller and its programming arrangement together.
Matching the package to the programmer
This package is relevant to PLC programming and service preparation for existing S5 installations. When handling STEP 5 projects, consider both the programming representations and the files holding blocks, symbols and comments. Follow the procedures supplied for the actual software release.
Match the PG 685 hardware variant, operating environment and software release together. When selecting PLC programming software, a family name alone is insufficient. Ask for the offered release to be demonstrated on the intended programmer and check the product information supplied with that package.
Checking the PG-to-PLC connection
Select S5 cables and connectors for the CPU’s programming port. S5 programming connections use a 20 mA TTY interface; arrangements using V.24 require suitable conversion. Distinguish the role of S5 interface modules from the programmer connection and check the required port, cable and conversion arrangement in the equipment manual.
If communication fails, inspect the PG port, cable and CPU condition first. The presence of an S5 communications module does not establish that the selected programming route is correct. Include the S5 power supply and controller supply conditions in the checks if CPU power is unstable.
Preparing backups and diagnostic records
For PLC 135 WB/WB2/WD systems, Siemens describes examining system parameters, addresses, BSTACK and USTACK through the programmer. Save the records collected during PLC troubleshooting. Compare digital input and digital output addresses with the electrical drawings to identify the field signals referenced by the program.
Include the full order numbers of S5 analog modules and the addresses of combined input/output modules in the backup notes. This allows the hardware arrangement and program files to be compared after a module replacement. The software package number does not define an I/O module’s signal range or channel specifications.
Consider the program on an S5 memory module, blocks uploaded from the CPU and original PG project files together. Preserve symbol and comment files separately; an upload from the CPU should not be assumed to contain the complete project archive. Add the date, machine identifier, CPU order number and software release to the backup record.
Identify any additional configuration tools required for S5 function modules and S5 special modules. Check that the relevant COM or supplementary software is present and compatible with the installed release. Siemens lists the S5-DOS ST supplementary package and GRAPH 5 as separate items in its ordering table.
Editor’s Note
Start with package completeness. Check that the media labels, software release and accompanying documents belong together. When working through common PLC maintenance questions, keep the exact CPU and PG order numbers beside you. Those two identifiers make a service discussion much more useful than a general description of the equipment.
If an old disk cannot be read, preserve it before attempting any write or format operation. Check the drive with known good media first. Keeping the original intact and backing up readable content is a sensible first step with software of this age.
For a used package, request the original media, package documentation and any licence paperwork together. Seeing an installed program on a PG does not establish what the sale includes. Agree the supplied software and documents in writing before purchase.
On a running installation, save the existing program and available diagnostics first. Begin with reading and comparison. Writing blocks before comparing the old project with the CPU program can introduce unexpected behaviour into an established machine.
Before travelling to site, check that the PG starts, the media can be read and the correct cable is packed. Photograph the S5 rack and module arrangement as well. The CPU identifier, programming port and module positions will save time when investigating the installation.
OtomasyonAVM resources and PDFs
+ PG 685 / 6ES5 685-0UA11 programmer page and Siemens S5 PLC background guide.
+ Shared SIMATIC S5 PDF archive. Check the scope of the system documents listed there; this archive link does not provide the 6ES5 885-0SA11 installation software.
Related topics
+ PLC programming, PLC troubleshooting and S5 cable and connector selection.
Browse SIMATIC S5
+ S5 supplementary hardware and software products · SIMATIC S5 · Siemens S5 PLC · Siemens second-hand main page.
Siemens and external references
+ Siemens Working with S5-DOS/ST, C79000-G8576-C760-03, English; general reference for the STEP 5 V6.6 environment. Compare this edition’s installation requirements with the actual release of the older package.