6ES5 491-0LC11

Siemens 6ES5 491-0LC11 Adapter Casing for Six Modules

Siemens 6ES5 491-0LC11 is a triple-width adapter casing for S5-115U/H/F systems in the SIMATIC S5 range. Siemens ST 50 (1998) specifies up to six ES 902 compact modules, dimensions of 129 × 303 × 187 mm and an approximate weight of 1.8 kg. For this S5 supporting component, dimensions are given as width × height × depth.

Select the casing together with the intended boards, subrack identification and available slots. Check electrical and functional compatibility with the SIMATIC S5 CPU using the individual board documentation. Mechanical accommodation alone does not establish that every board can operate with that CPU.

Differences between 0LB11, 0LD11 and 0LC11

The ST 50 table lists the 6ES5 491-0LB11 as single-width for up to two modules, and the 6ES5 491-0LD11 as double-width for up to four modules. The 0LC11 is the triple-width version for six modules. Compare the full suffix and required front-panel space before ordering.

Subrack and board arrangement

Record the complete carrier identification when selecting an S5 subrack. In an arrangement using a CR 700-3, CR 700-0LB or ER 701-3, check casing width and intended slots against the existing layout drawing. Allow for adjacent boards, cable exits and maintenance access.

The S5-115U manual specifically identifies the 491-0LC11 casing for the CP 551. For interface modules and communications processors, verify each board’s permitted slot and system requirements separately. Guide positions in an empty casing are insufficient evidence of universal board compatibility.

Installation and connection checks

Photograph the positions of digital input, digital output, combined I/O and analog boards before dismantling. Guide each board into position without forcing it. If it catches, inspect the guides, locking parts and connector alignment rather than drawing it into place with a screw.

Check that cables and connectors are clear of the cover and do not pull a board sideways. Isolate the system supply and relevant field supplies before installation. Retain screws, covers and mounting parts with their positions identified; avoid substituting an arbitrary screw length.

Cooling and covers

Siemens’ S5-115H installation manual requires a fan for adapter casings containing two printed circuit boards. Verify cooling against the requirements of the installed boards and system. Keep ventilation openings clear of cables, contamination and added parts.

Inspect front openings and the condition of the protective cover. Record missing or modified covers in the supply list. Where a fan is installed, check the clear airflow path and filter condition as well as whether the fan rotates.

Accepting a used casing

For a casing removed from an older Siemens S5 installation, inspect for distortion, broken guides, stripped fixing points and loose locking parts. Record the original board arrangement and the positions of memory modules. Plan backup and board removal according to the relevant CPU or board maintenance instructions.

The quotation should state the complete 0LC11 identification, actual dimensions, physical condition and included covers and mounting parts. Specify separately whether boards, connectors or a fan are included. A catalogue photograph does not establish the contents supplied with a used casing.

Editor’s note

Start with the casing label and width. Members of the 491 family can look similar while requiring different installation space. Confirm the 0LC11 order from photographs of the actual triple-width casing.

Capacity for up to six boards is only the starting point for planning. Board thickness, slot allocation and adjacent clearance still matter. Keep photographs and a board list from the original arrangement available for comparison.

If a board catches in its guide, stop and inspect the casing. Look for distortion, a broken guide or a loose screw inside. A mechanical defect should not be allowed to damage an otherwise sound board.

Include the fan and airflow path in the inspection. A missing fan, blocked filter or obstructed opening may only become apparent as the system warms up. A short bench run does not establish performance in the temperature conditions of a closed cabinet.

Ask for close photographs of the cover, locks and mounting parts. Missing special fittings can leave an apparently useful purchase incomplete. Use a clear supply list and establish whether any boards shown are included.

OtomasyonAVM resources and PDFs

+ 6ES5 491-0LC11 product and information page and Siemens S5 models.

+ OtomasyonAVM shared SIMATIC S5 PDF archive.

+ OtomasyonAVM S5-115H System Manual, English PDF, for adapter-casing installation and cooling requirements.

Related topics

+ 491-0LB11 two-module casing, 491-0LD11 four-module casing and the CP 551.

+ S5 subracks, S5 cables and connectors and about Siemens S5 PLC.

Browse SIMATIC S5

S5 supporting modules  |  S5 subracks  |  Siemens S5 models  |  Siemens second-hand homepage

Siemens and external references

+ Siemens SIMATIC S5 ST 50, 1998, English catalogue archive copy. The exact-order-number table on printed page 3/98 provides capacity, dimensions and weight.

+ Siemens S5-115U System Manual, English. EWA 4NEB 811 6130-02b, Edition 04; subrack layouts and casing use with the CP 551.