Siemens 6ES5 101-8UC31 — SIMATIC S5-101U Transistor Expansion Unit
The Siemens 6ES5 101-8UC31 adds 20 digital inputs and 12 transistor outputs to an S5-101U system in the SIMATIC S5 range. An S5-101U central controller such as the 6ES5 101-8UA33 runs the program. The expansion unit exchanges field I/O signals with the controller. When replacing S5 I/O hardware, check for the full 8UC31 suffix on the nameplate.
Power supply and I/O ratings
The unit is rated at 24 V DC, with a permitted supply range of 20–30 V DC. When sizing the external DC power supply, calculate the unit’s supply current and the current drawn by the output loads separately. The digital inputs are rated at 24 V DC and share the M3 reference. For a two-wire inductive proximity sensor, check its electrical ratings against the 22–30 V DC sensor supply condition in the Siemens input table.
The digital outputs are arranged in two groups of six. Siemens specifies a per-output current limit of 1 A up to 40 °C and 0.5 A up to 55 °C. Apply the separate limits in the manual for lamp and inductive loads. Use Figure 16 to check the load supply and reference terminals for each output group.
Host connection and I/O addresses
The S5-101U expansion interface connects the central controller and expansion unit through a short ribbon cable. When identifying the S5 cable, match the expansion connector and its fasteners. Each unit has its own supply input. Siemens specifies connecting the two E terminals as shown in Figure 16.
Figure 16 assigns inputs I 3.0–I 5.3 and outputs Q 2.0–Q 3.3. Leave the I 5.3 terminal unwired when that address is reserved for fault monitoring. In this configuration, I 5.3 = 1 indicates a complete loss of the expansion unit, such as loss of its supply or a break in the host bus connection. The expansion outputs are disabled when the host goes to STOP.
Related S5-101U variants
The 6ES5 101-8UC11 is a relay expansion unit with the same 20 inputs and 12 outputs and a 220/240 V AC supply. The central controller range includes the full-complement relay 8UA13, the 10-input/6-output relay 8UB13 and the triac 8UA23. Match the unit’s role, supply voltage and output technology when selecting a replacement.
Buying and testing a used unit
Ask for a nameplate photo and close-ups of the ribbon cable, connector screws and output terminals. Confirm that both output groups were tested with suitable loads and that the central controller could read the inputs. When troubleshooting, check the processor and memory submodule at the central controller. The 375 EPROM submodule, for example, belongs to the central controller’s program memory configuration.
Siemens lists the PG 605U, the PG 615 and the 6ES5 731-1BD20 programming cable for the PG 670/675 in its accessory table. If the installation uses SINEC L1, trace the communications connection at the central controller’s TTY port.
Editor’s Note
On the bench, test at least one output from Q 2.0–Q 2.5 and one from Q 2.6–Q 3.3 with a suitable load. Verify that the load operates when the output LED lights. If the program uses I 5.3 for fault monitoring, check that its terminal is unwired.
PDF archive
See printed page 2-10 for the terminal diagram, 3-3 for expansion operation and I 5.3 diagnostics, and 5-1 and 5-4 for the supply and I/O ratings. Shared Siemens SIMATIC S5 PDF archive
Related topics
About Siemens S5 PLCs · S5 digital I/O modules
Navigation · S5 central and expansion units · Siemens SIMATIC S5 PLC · Used Siemens automation equipment
Reference
Siemens SIMATIC S5-101U Operating Instructions, 6ES5 998-0UC23, EWA 4NEB 810 2119-02c (English PDF)