6ES5 902-3SA11

Siemens 6ES5 902-3SA11 — S5-110S CPU 902 central processing board

Siemens 6ES5 902-3SA11 is a CPU 902 central processing board used in the SIMATIC S5-110S controller. This CPU board in the Siemens S5 family executes the user program and works with the system’s peripheral hardware. Select a spare using the complete part number, board revision and installed program memory.

Although grouped within S5-90/110 modules, the 902-3SA11 belongs to S5-110S. 6ES5 902-3SA12 is another order version, while CPU 900 / 6ES5 900-7AD11 is different hardware associated with S5-110A. A similar front panel or shared S5 name does not establish interchangeability.

Program memory and EPROM arrangement

Siemens’ S5-110S/B architecture distinguishes the user EPROM submodule on the CPU from separate 340 RAM and 350 RAM/EPROM boards. Record both the CPU-mounted module and any additional rack memory when inspecting memory hardware. Distinguish RAM contents, the EPROM program and the backup condition.

Do not assign a fixed program capacity to 902-3SA11 without identifying the fitted memory and its contents. Instruction capacity and byte/KB capacity are different units in the documentation. Memory supplied with a used CPU does not establish that it contains the correct machine program.

Programmer interface and STEP 5 connection

The S5-110S arrangement uses a separate 511 programmer interface board. The S5-110S/B spare-parts list identifies 6ES5 511-5AA12. For another version, such as 6ES5 511-5AA14, verify the programmer model, software level and system compatibility separately.

Select the interface board, programming cable and STEP 5 programming equipment together. Siemens distinguishes the 511 programmer connection from the 512C communications connection; similar connector appearances do not justify interchanging their cables.

Rack, internal supply and 110 bus

The S5-110S CPU circuitry operates from the system’s internal 5 V supply. Check the complete part numbers of power-supply/housing versions such as 932-3SA11 and 932-3SA12. The power supply’s mains or 24 V input rating is not a voltage to apply directly to the CPU.

The family manual shows digital peripherals connected through the CPU front connectors and 110 bus. Record the mounting-rack layout and expansion arrangement. When checking digital input and digital output addresses, examine the peripheral board’s physical position together with its bus connection.

STOP, BASP and fault-finding

In the S5-110S/B documentation, BASP indicates output inhibition. Assess STOP and BASP indications together. During fault-finding, check the supply, memory, programmer interface, peripheral cabling and program condition in sequence. Record the interrupt-stack information and observed LED states as part of S5 maintenance.

Documentation scope: The Siemens S5-110S/B manual used here lists 902-3SA12 as the spare CPU. These descriptions explain the family architecture; they do not establish 3SA11-specific current, instruction timing, memory capacity or revision equivalence with 3SA12.

Editor’s note

When buying used Siemens equipment, inspect the 902-3SA11 label, board revision and fitted EPROM. A CPU without its memory and a board supplied with a documented program are different delivery configurations.

Before removal, photograph the front bus connectors, memory submodule and programmer interface. Label the connectors to preserve the installed arrangement and address references.

Check for bent contacts, oxidation, a loose memory socket and previous repairs. Remove or insert the CPU and memory with system power off and suitable static-discharge protection.

If BASP is illuminated, assess the CPU STOP state, service-switch positions, supply and program together. Record the indications before making changes to the installed configuration.

Test in a suitable S5-110S rack with the correct memory and programmer connection. Back up the existing program and record the memory, interface and test program alongside the CPU part number and result.

OtomasyonAVM resources and PDFs

6ES5 902-3SA11 model page · SIMATIC S5 CPU family · Used Siemens equipment. For other S5 documents, visit S5-115 PDF files. The S5-110S/B family manuals below are identified by their actual languages.

Related topics

+ 6ES5 902-3SA12 — another CPU 902 order version.

+ 6ES5 932-3SA11 — a related S5-110S power-supply/housing version.

+ 6ES5 511-5AA12 — the programmer interface listed in the S5-110S/B manual.

+ 6ES5 900-7AD11 — a different CPU family associated with S5-110A.