6ES5 393-0UA12

Siemens 6ES5 393-0UA12 – OP 393-II Operator Panel

Siemens 6ES5 393-0UA12 is the OP 393-II operator panel for the SIMATIC S5 family. Its two-line LCD with 16 characters per line, numeric keypad and function keys provide access to PLC timer, counter and supported data values. Among operator panels, it is a compact model intended for local operation and maintenance.

It is particularly associated with S5-100U and S5-115U applications. When matching Siemens S5 models, check the complete panel order number, startup software version, CPU and cable together. The S5 CPU family name alone is insufficient: the manual's OP 393/OP 393-II column does not list connection support for S5-115U CPU 945 or S5-155U.

Display, keypad and operation

The 2 × 16-character LCD displays numeric values, function information and messages prepared by the application. Physical keys handle numeric entry, confirmation and function selection. When reviewing Siemens operator panels, use the keypad and function arrangement for the installed OP 393-II version. Not every function shown on the OP 393-III keypad drawing applies to this model.

Power supply and technical data

The Siemens table explicitly specifies 5.2 V / 0.5 A for 6ES5 393-0UA12. In the appropriate connection arrangement, power comes from the PLC through the connecting cable. The 0.1 A figure for the 0UA13/0UA14/0UA15 group does not apply to this model. Do not apply 24 V directly to the panel's signal or power connections.

The specified operating temperature is 0 to +45 °C, storage temperature −20 to +55 °C, enclosure dimensions 200 × 120 × 45 mm and weight approximately 700 g. Protection is IP50, or IP54 with the appropriate mounting frame. The 214 × 135 mm figure is the panel cutout for installation with the frame, not the enclosure dimensions.

TTY communication and connecting cable

The interface is serial TTY, 20 mA current loop. Do not select an RS232 or RS485 cable solely by connector shape. With S5 cables and connectors, check both the data circuit and the panel's power path. The manual requires a 984 cable adapter for connections longer than 3 metres.

The OP 393/OP 393-II connection table also shows S5-90U, S5-135U and S5-150U connections using a 984 adapter. Select the arrangement for the CPU and cable length. When reviewing S5 auxiliary and expansion equipment, verify the exact adapter order number and supply requirements; different 984 or 728 components cannot automatically be treated as equivalent.

Timers, counters and data words

The TMR and CTR functions access the PLC's internal timer and counter values. The values changed here are data used by the PLC program. When comparing this operation with a timer relay, consider the difference between a timer relay and a timer; do not wire the panel as though it provided physical relay contacts.

The manual describes diagnostic messages and data-word input/output from V2.0 onward. Available functions must match the installed version and PLC data structure. Data blocks prepared during PLC programming determine the values and messages available to the panel. Back up the CPU program and relevant data blocks using suitable S5 programming software before maintenance.

DB6 parameters and addressing

DB6 is the parameter data block used for startup settings from V2.0 onward. The manual states that up to V2.1, DB6 must not exceed eight data words, DW0 through DW7. Do not load the extended V3.0 DB6 structure unchanged into an older version. The panel reads DB6 during startup and does not automatically adopt changes made to DB6 while running.

When DB6 is absent, documented default allocations include DB11 for TMR, DB12 for CTR, DB13 and MW0/2 for TXT, and DB14 for data input. Where the existing project's DB6 selects different areas, follow that allocation. For an *89 message, inspect the parameter structure and required data blocks. During PLC troubleshooting, do not automatically interpret this message as a display hardware fault.

Differences from related order numbers

6ES5 393-0UA11, 6ES5 393-0UA13 and 6ES5 393-0UA15 are separate order numbers within the OP 393 family. Compare supply current, connection facilities and software functions. In particular, password protection and flag control introduced with V3.0 must not be presented as standard 0UA12 features.

PLC model and version differences also matter when replacing the panel with another version. Siemens specifies a particular condition for DL3, DL4 and DL6 when moving from V2.0 to V2.1. Back up the existing blocks before copying parameters from another panel installation.

Used equipment checks and modernization

When buying a used HMI panel, test every display character position, numeric key, confirmation key and function key used by the application. For used Siemens automation equipment, establish whether the cable, connector lock and any mounting frame are included. A successful startup screen alone does not verify complete PLC data exchange.

During modernization, touchscreen HMI panels and Derell HMI panels may also be assessed as project options. Replacing an OP 393-II requires a separate solution for the TTY physical interface, S5 communication support and data addressing. These product groups are not confirmed drop-in replacements.

Editor's Note

Start by photographing the label and the version shown during startup. OP 393 units can look similar while requiring different current or offering different functions. Before accepting a replacement, check that the actual CPU and panel communicate correctly together.

This model is specified at 5.2 V / 0.5 A. Do not connect a familiar 24 V supply out of habit; first identify the correct cable and power path. If the panel repeatedly restarts, check the cable and voltage drop through the connection before condemning the unit.

Visible text is only the start of the test. Try every numeric key, ENT and each function key used by the application. Read a known value in a controlled test. If a value must be changed, make sure the machine is in an appropriate condition and record the original setting.

For *89, inspect DB6 and the associated data blocks first. A missing or incorrectly structured block can stop a healthy panel from performing its task. Back up the working plant's blocks and settings before trying an example program.

A spare panel may also need the correct TTY cable, a 984 adapter where required, and the mounting frame. Confirm those items before purchase. On an older system, a sound keypad and a test with a real PLC connection are as valuable as a clean enclosure.

OtomasyonAVM resources and PDF archive

Siemens 6ES5 393-0UA12 main page · Used Siemens S5 models · OtomasyonAVM S5 PDF archive

The Siemens manuals below cover technical data and parameter structures for the OP 393 family. The German document is 6ES5 998-0UQ12 / EWA 4NEB 810 1180-01g; the English document is 6ES5 998-0UQ22 / EWA 4NEB 810 1180-02f. Both cover more than one OP 393 version.

Related topics

6ES5 393-0UA11 · 6ES5 393-0UA13 · 6ES5 393-0UA15 · Derell HMI panels

Navigation

SIMATIC S5 · Siemens panels · S5 cables and connectors · Used HMI panels

External references

Siemens OP 393 manual – German, technical data and exact-model power table, printed page 2-1.

DB6 structure and version migration, printed page 3-1 · Siemens OP 393 Manual – English, connection table, printed page 1-1 (archived copy of the manufacturer's document).