6EW1160-6AA

Siemens 6EW1160-6AA SINUMERIK Operator Panel Power Supply

Siemens 6EW1160-6AA is a power supply module used in the operator-panel and keyboard-interface section of SINUMERIK 840C/840CE systems. The Siemens nameplate specifies 230 V AC, 50–60 Hz, 200 mA input and output entries of 5.1 V DC / 2.5 A and 5.1 V DC / 0.25 A. This CNC control component must be distinguished from a general-purpose 24 V industrial power supply.

The nameplate also carries part number 568 980 TA. Within our Siemens 6EV / 6EW model group, this reference identifies the supply module, rather than the complete operator panel on which it is mounted. Current SITOP power supplies and general selection principles are covered separately in our Siemens SITOP guide.

The 25 W marking and two output entries

The nameplate lists 25 W under “Leistungsaufnahme”, meaning power consumption. It should not be described as the output power rating. Assess voltage and current together with their respective nameplate entries. Adding the currents to describe a single 5.1 V / 2.75 A output, or paralleling connections, requires technical information that these markings alone do not provide.

Take readings with a suitable multimeter at positively identified terminals. The older 230 V AC keyboard-interface drawing identifies the mains connections as L1, L2/N and PE. Do not assume that protective earth, circuit common and output references are interchangeable. Output connector pin functions must be established before applying power or a test load.

Unresponsive keys: supply fault or interface fault?

Keys or softkeys failing to respond do not by themselves establish a defective power supply. Inspect the keyboard interface, cables and RS-232 communication as well. RS-232 and RS-485 are different electrical interfaces; supply checks and communication checks should be treated separately.

For the older keyboard interface, Siemens states that the yellow H2 LED goes dark below 4.75 V or during RESET. The red H3 LED going dark is associated with correct transmission in the relevant RS-485/MPC configuration. These are interface-board indicators, rather than independent fault LEDs on the supply module.

The PLC and machine control may continue operating while individual panel functions fail. Measure the specified supply points under load before moving on to cable and interface diagnosis. Contact problems in connectors and other power supply accessories can also affect the readings.

Comparing other Siemens references

6EW1861-2AB and 6EW1861-3AD identify different Siemens supplies. A shared 6EW prefix or a similar output voltage does not establish interchangeability. Match the 6EW1160-6AA mounting arrangement, output functions and panel connections together.

Editor’s note

When sourcing used CNC control equipment, look beyond a photograph of the complete panel. Record 6EW1160-6AA from the power supply label separately from the panel’s own order number. Establish which component is actually required before ordering.

The nameplate specifies 5.1 V. Do not transfer the adjustment value of a different Siemens supply to this unit. If investigating low voltage, compare the supply output with the interface’s power input and check connector losses before adjusting anything.

If a panel works cold but loses keys or restarts after warming up, investigate voltage fluctuations and regulation under load. A steady multimeter average can conceal brief dips. Use suitable oscilloscope probing for ripple checks; do not invent a millivolt acceptance limit without model-specific evidence.

Before internal repairs, disconnect the mains and verify that capacitor voltage has discharged. Investigate rectifier or power-semiconductor shorts, capacitor capacitance/ESR, cracked solder joints and overheated connections. Replacement parts must match their electrical requirements and operating conditions, as well as their physical appearance.

Ribbon cables deserve attention during CNC maintenance. Bent pins, reversed plugs or loose connections can make a healthy supply appear faulty. Do not bridge safety contacts while diagnosing the panel; maintain a safe machine condition when working around its emergency-stop circuit.

When testing used Siemens equipment, increase the load gradually, stay within the nameplate currents and record behaviour after warming up. Identify the actual connections associated with both output entries before applying loads. Producing voltage without load does not establish reliable operation in the panel.

OtomasyonAVM resources and PDFs

Continue identification through our Siemens 6EV / 6EW model pages. Our documentation hub is the Siemens SITOP files page.

+ SINUMERIK 840C Interface Description, Part 2: Connection Conditions – 09.2001, English, 433 pages. Printed page 2-71 shows the older 230 V AC keyboard interface; pages 2-72 / 2-73 cover connections and indicators.

Source scope: Electrical nameplate values were read from the Siemens manufacturer label bearing the exact 6EW1160-6AA reference. The PDF describes the system’s keyboard interface; it is not a component-level repair schematic for this power supply. Keep old and new interface versions separate when checking connections.

Related topics

+ Multimeter checks + RS-232 communication + RS-232 / RS-485 differences + Voltage fluctuations

Used-equipment enquiries: Provide the brand, complete model, quantity, working/faulty condition, nameplate photographs and asking price. Sales are invoiced; returns are not accepted for used equipment. Workshop testing is possible where suitable conditions are available. To offer equipment for sale, send its details to otomasyonavm@gmail.com.

Browse categories

+ Siemens 6EV / 6EW models + SITOP power supplies + Used Siemens equipment + Operator panels + SITOP PDF archive

Siemens and external references

+ Original Siemens SINUMERIK 840C Connection Conditions manual

+ Equipment photographs showing the 6EW1160-6AA manufacturer label. Electrical ratings were assessed from the Siemens nameplate visible in the photographs.