6ES5 301-5AA13
Siemens 6ES5 301-5AA13 – IM 301 Distributed Expansion Interface, A Version
6ES5 301-5AA13 is the Robustbauform/A-version IM 301 interface module for S5-130A and S5-150A systems in the Siemens SIMATIC S5 family. This S5 interface supports distributed expansion over a total distance of up to 200 m using 721-series cable, alongside local rack connections through IM 312 modules.
The SIMATIC S5 ST 53 catalogue specifies this exact code for up to four centralized expansion racks through IM 312, while also connecting an EG 182 or EKL 484 through IM 310.
Supported controller and rack arrangements
The A-version distributed arrangement uses an EG 182-3A with a 6ES5 310-5AA12 – IM 310-5 at the receiving end. The total distance from the central controller to the furthest expansion unit is limited to 200 m.
On the local expansion branch, EG 180-3A and EG 181-3A racks connect through IM 312-5. Versions such as 6ES5 312-5AA13 and 6ES5 312-5AA31 have different cable lengths and rack positions; select them to suit the actual cabinet layout.
The manufacturer's S5 rack table assigns the 301-5A to position 8 in ZG 130A and position 9 in ZG 150A. When checking PLC racks and slots, distinguish the A construction from compact systems.
721 cable and interface roles
The S5-115U CPU 945 manual's cross-system table also pairs the 301-5AA13 on the 130A/150A side with a 6ES5 310-3AB11 in ER 701-2/ER 701-3, using 721 cable with a 200 m limit.
When selecting S5 cables and connectors, check more than length. For a 721-family cable such as 6ES5 721-0BB00, verify the full order number, pin assignment, shield connection and installed interface version together.
For the A-version 310-5AA12, the ST 53 ordering table specifies the 6ES5 760-0AA11 terminator. Confirm the termination part against the actual receiving IM 310 version.
EKL 484 and centralized expansion
The EKL 484 is an electronic terminal strip and distributed I/O assembly. As a connection target in the catalogue, it serves a different function from a passive line-termination plug. Check the remote I/O connection and line termination separately.
For the local rack branch, ST 53 specifies a maximum total cable length of 2 m from the central controller or EG 182 to the last local rack. The 200 m distributed limit and 2 m centralized limit apply to different connection branches.
Supply arrangement and related IM 301 versions
The local EG 180/181 group receives power from the central controller or its associated EG 182 power supply. ST 53 specifies an internal 5 V supply and a 5 A total load limit for this arrangement. Include the combined module load when checking the PLC power supply; 5 A is not the IM 301's own current consumption.
6ES5 301-5CA12 is specified for connecting A-construction racks to compact central controllers, while 6ES5 301-3AB13 is a separate compact-system version. Do not treat 5AA13, 5CA12 and 3AB13 as automatically interchangeable.
Troubleshooting and used-module selection
Compare the PLC program and address plan against the actual I/O layout. During troubleshooting, examining the local expansion branch and the 200 m distributed branch separately helps locate the affected section.
If the PLC CPU runs but a remote rack becomes inaccessible, first check the remote supply, 721 cable, IM 310 and termination. Loose, corroded or bent connector contacts can produce similar symptoms.
For used Siemens equipment, inspect the 6ES5 301-5AA13 label, A-construction suitability, connections and previous repairs. After confirming the S5 system architecture, perform actual I/O read/write tests on the connection branches that will be used.
Editor’s note
Start by comparing the complete order number and A-construction rack. The IM 301 name alone is not enough. Choosing the right part at the outset is easier than finding a workaround inside the cabinet later.
Before disconnecting anything, mark the local rack branch and the line to the remote IM 310 separately. Leave a small sketch and a few photographs, so every cable has a clear destination during reassembly.
The 200 m allowance applies to the whole route from the central controller to the end of the line. Add the cable lengths together, and keep the separate 2 m local-rack limit in mind.
Do not mistake the EKL 484 for a termination plug. One performs I/O functions; the other completes the line. Read the full code of the final IM 310 before choosing its terminator.
If a remote rack disappears, check before condemning the 301. Start with the remote supply, cable and contacts. Switch off power for removal or insertion, then verify actual I/O access under suitable machine shutdown conditions.
OtomasyonAVM resources and PDFs
Start with About Siemens S5 PLC, S5 interface modules and S5 cables/connectors.
The OtomasyonAVM Siemens S5 PDF archive collects our available documents. The German ST 53 catalogue documents this model's A construction and interface roles. The English CPU 945 manual's cross-system connection table documents the ER 701 arrangement.
Related topics
+ 6ES5 310-5AA12: the receiving interface in the A-version distributed arrangement.
+ 6ES5 310-3AB11: the interface listed for the ER 701 connection.
+ 6ES5 312-5AA13 and 6ES5 312-5AA31: local rack connections.
+ 6ES5 301-5CA12 and 6ES5 301-3AB13: different IM 301 construction options.
Browse SIMATIC S5
S5 interface modules · S5 racks · S5 cables and connectors · Used Siemens equipment
Siemens and external references
+ Siemens ST 53 – S5-130 and S5-150 Catalogue, 1985 / May amendments, German: printed 2/5 / PDF 19 for the 2 m and 200 m limits and supply arrangement; printed 2/9 / PDF 23 for A construction, module roles and slots; printed 9/3 / PDF 121 for the exact 301-5AA13 code, centralized/distributed connections and interface options.
+ Siemens S5-115U CPU 945 Manual – 6ES5 998-3UF21, English: §3.3.3, Table 3-5, printed 3-20 / PDF 142; pairing of 301-5AA13 on the 130A/150A side with ER 701-2/701-3, 310-3AB11 and 721 cable.