6ES5 988-7NA11
Siemens 6ES5 988-7NA11 S5-115U/H/F Replacement Fan Package
Siemens 6ES5 988-7NA11 is a replacement fan package for S5-115U/H/F fan subassemblies in the SIMATIC S5 family. Siemens ST 50 lists one fan, a plug-in connector and replacement instructions. Treat this S5 service accessory separately from a complete fan subassembly.
The catalogue associates the package with 6ES5 981-0HA11, 981-0HA21, 981-0HB11 and 981-0HB21 subassemblies. Record the label of the installed 981-0HA11 or 981-0HA21 unit. A used-item quotation should identify which connector parts are actually included.
One replacement fan or a complete subassembly?
A complete subassembly contains two fans, a filter and fan monitoring equipment. The 988-7NA11 package specifies one fan. Inspect the housing below the rack, the 981-0GA11 mounting accessories and any 491-0LC11 adapter casing as separate items.
Supply and connector checks
Do not apply the subassembly’s input-voltage rating directly to the replacement motor. Review the power supply and subassembly wiring together with the motor label and package instructions. For cables and connectors, check contact arrangement, locking and cable condition as well as physical fit. Isolate the relevant supply before replacement.
6ES5 988-3LA11 and 6ES5 988-3NA11 identify different fan units. A shared “988” prefix or similar connector does not establish interchangeability with the 7NA11 package. Select the part against the complete order number.
Airflow, filter and mechanical installation
Check airflow direction, seating and cable clearance from the blades. Where the installation includes 491-0LB11 or 491-0LD11 adapter casings, photographs of the original module arrangement and air path make comparison after servicing easier.
Inspect the filter and air path as well as fan rotation. Check for cables obstructing airflow around the S5 CPU and communications modules. Comparing temperatures under the same operating conditions before and after servicing helps assess the result.
Fault monitoring and acceptance testing
Trace the subassembly’s fault output using the machine wiring diagram. If monitoring passes through interface hardware, a digital input or an external alarm circuit, check that the relevant signal changes. Record the resulting alarm response from the output circuits.
A PLC program change that silences an alarm does not complete a fan repair. Record any changes to program memory or alarm logic separately. Acceptance records should distinguish cold starting, noise, vibration, operation of both fans and monitoring results.
Editor’s note
Ask for clear photographs of the 988-7NA11 package marking, motor label and connector. Catalogue contents and the contents of a used-item offer can differ. A missing connector can delay an otherwise straightforward repair.
One successful start is a limited test. Check several cold starts and note delayed starting, rubbing or vibration. A rotor that turns freely by hand still needs an electrical running test.
Inspect the old filter when fitting the replacement. Restricted airflow can limit the benefit of a new fan. During cleaning, avoid carrying accumulated dust further into the electronic modules.
The subassembly has two fans, while this package specifies one. Check the remaining fan separately after replacement; the new fan’s sound can mask a noisy older motor.
Include the alarm circuit in the final check. Do not leave monitoring bypassed because the fan now rotates. Record which fan was replaced, the connector parts used and the actual alarm-test result.
OtomasyonAVM resources and PDFs
+ 6ES5 988-7NA11 product and information page, 981-0HA11 fan subassembly and 981-0HA21 fan subassembly.
+ OtomasyonAVM SIMATIC S5 PDF archive. Section B.4, Replacing the Fan Motor, in the S5-115U manual confirms the package code and contents. It refers removal and installation details to the instructions supplied with the package.
Related topics
+ Fan mounting accessories, S5 racks, cables and connectors and about Siemens S5 PLC.
Browse SIMATIC S5
Siemens S5 models | S5 supporting equipment | S5 function modules | Siemens second-hand homepage
Siemens and external references
+ Siemens S5-115U Programmable Controller Manual, English. EWA 4NEB 811 6130-02b; filter maintenance in B.3 and the exact 988-7NA11 package in B.4.
+ Siemens ST 50, 1998, English manufacturer catalogue — third-party archive copy. Printed page 3/77 covers S5-115U/H/F fan subassemblies and replacement-fan ordering data.