6ES5 988-3LA11

Siemens 6ES5 988-3LA11 EG 184U Fan Draw-Out Unit

The Siemens 6ES5 988-3LA11 is an AC-powered fan draw-out unit for the EG 184U expansion unit. 6ES5 988-3LA11 helps remove heat from the SIMATIC S5 rack and reports fan stoppage through a Fan Fault LED and Monitor Output relay contact. It forms part of the cooling and maintenance arrangements for Siemens S5 PLC installations.

When selecting Siemens spare parts, check the complete fan-unit code, rack label and electrical connections together. For EG 184U records such as 6ES5 184-3UA11 and 6ES5 184-3UA21, use the actual unit's hardware arrangement as the reference. In a PLC and automation cabinet, mechanical similarity alone does not establish a suitable replacement.

AC supply and voltage selector

The manual specifies 115 V, 120 V or 230 V settings for the S13 voltage selector, with a factory setting of 230 V. The Siemens product summary uses the description 240/115 V AC. Before commissioning, verify the unit label, available supply and actual selector position together.

The input frequency is 50/60 Hz, with a documented range of 48–63 Hz. Input current is approximately 0.24 A at 230 V or 0.48 A at 120 V. The AC supply connects to L1 and N; also check the protective conductor connection and cable strain relief.

6ES5 988-3LA11 and 6ES5 988-3NA11 do not use the same supply. The manual identifies 3NA11 as the 24 V DC variant. Do not connect AC and DC variants interchangeably based on appearance.

Fan Fault indication and relay contacts

Stoppage of one or both fans is reported through the red Fan Fault LED and relay contact. The front plate marks the Monitor Output relay at 250 V AC / 3 A maximum. Assess the alarm circuit's voltage, load and protection requirements separately.

During normal operation: contact 1–2 is closed and contact 2–3 is open. During a fault or with the fan unit switched off: 1–2 is open and 2–3 is closed. Check whether power is present when interpreting the relay state.

An external alarm circuit can report fan faults to maintenance personnel or the machine's monitoring system. Confirming that the installed circuit actually detects the relay signal provides a more complete check than inspecting the LED alone.

Rack cooling and maintenance checks

Maintain clear airflow around the S5 power supply and rack modules. Assess dust accumulation, obstructed air passages, loose fan connections and worn bearings individually. A rotating fan alone does not prove adequate rack cooling.

In S5 installations containing a CPU 928B or CPU 948, include cabinet ventilation when investigating temperature-related interruptions. These CPU links provide system context; they do not imply that this fan unit fits every CPU rack.

The manual lists approximately 52 W maximum heat dissipation at rated load, including fans. This is not a cooling-capacity rating. Assess airflow direction, fan condition and the rack's environmental requirements together.

Related fan codes and replacement parts

6ES5 988-3NB41 and 6ES5 988-7NA11 are replacement fan packages; 6ES5 981-0HA11 and 6ES5 981-0HA21 are other S5 fan-unit records. Do not treat them as direct 3LA11 replacements without checking rack connections, supply, mechanical dimensions and fault monitoring.

A complete fan draw-out unit and a replacement fan set are different parts. Siemens associates the 6ES5 988-3LB11 fan set with 6ES5 955-3LC12, 6ES5 955-3LC13, 6ES5 955-3LF11 and 988-3LA11. The 6ES5 988-3LB21 record lists 6ES5 955-3LC14, 6ES5 955-3LF12 and 988-3LA11. Check the existing unit's revision and service documentation before selecting a set.

Editor's Note

Ask for clear photographs of the front and rear labels. The difference between 3LA11 and 3NA11 may look small, but it changes the supply requirements. Keep the rack label beside them and compare the complete codes.

Do not stop at “the fan runs.” Check that both fans operate and that noise and vibration are normal. An older fan may become noisy as it warms up, so the assessment should cover more than a brief power-on check.

Have the actual voltage-selector position checked. Connecting a unit set to 120 V to a 230 V supply can damage it. Selector, fuse and internal-connection work must be carried out with power isolated by qualified personnel.

Test the relay output as well as the Fan Fault lamp. Normally, 1–2 should be closed and 2–3 open; the contacts reverse during a fault or when power is absent. If connected to the machine's alarm chain, confirm that the indication reaches the control system.

If fans have been replaced, check more than their dimensions: electrical ratings, airflow direction, connections and monitoring must also suit the unit. Replacing a fan without clearing an obstructed air path may leave the problem unresolved. Retain connection photographs and revision details.

OtomasyonAVM resources and PDF documentation

Use About Siemens S5 PLC for system information and the Siemens S5 PDF archive for documentation. For this model's connections, voltage selection and fault contacts, refer to S5-135U/155U System Manual, C79000-G8576-C199-07, section 4.5, pages 4-70–4-74.

Related topics

6ES5 988-3NA11 · 6ES5 988-3NB41 · 6ES5 988-7NA11 · S5 power supplies · EG 184U rack records

Navigation: 6ES5 988-3LA11 model page | SIMATIC S5 main page | Siemens S5 PLC models | Used Siemens products

Siemens documents and external references

Siemens S5-135U/155U System Manual — English PDF: section 4.5, fan submodules; PDF pages 136–140.

Siemens 6ES5 988-3LA11 product record: EG 184U fan draw-out unit description. 6ES5 988-3LB11 and 6ES5 988-3LB21 fan-set records.