Siemens 6ES5 944-7UA12 – S5-115U CPU 944, 96 KB RAM, one TTY interface
Siemens 6ES5 944-7UA12 is a CPU 944 processor for the S5-115U in the SIMATIC S5 family. It has 96 KB internal RAM and one TTY serial interface. When selecting an S5-115U CPU, check the complete order number, operating-system submodule and existing application together.
When sourcing a spare for a Siemens S5 installation, compare the interface count carefully. 6ES5 944-7UA22 is the two-interface version. 6ES5 944-7UB11 belongs to a different hardware series; the CPU 944 designation alone is insufficient for a replacement decision.
RAM and memory-submodule selection
RAM comprises two 48 KB banks. BANK 2 holds program blocks; program storage in BANK 1 depends on the operating-system version. For an S5 memory submodule, check the full order number as well as capacity. Do not add its capacity to internal RAM when calculating available working memory.
Prepare suitable programming software and connection hardware, then back up the STEP 5 application. Compare the running blocks with the memory-submodule contents. Do not assume the latest plant modification is already stored there. Record required data blocks and current settings separately.
TTY connection and communications
SI1 uses a 20 mA current-loop interface. When choosing an S5 programming cable, verify electrical conversion and the active/passive connection arrangement. During interface and converter checks, matching connector shapes is insufficient; compare the cable label with its connection documentation.
Record the existing connection arrangement for the programmer, operator panel or SINEC L1 application. Assess S5 communication modules against the project if additional connectivity is required. Establish the role of each connected device before planning parallel connections or protocol changes.
Execution time, timers and counters
The specification lists 128 timers, 128 counters and approximately 1.6 µs per binary operation. Do not use an individual instruction time as the complete PLC scan time. Assess actual execution, interrupts and communication load in the running application.
Compare the rack arrangement and program addresses when reviewing digital input and digital output modules. Before replacing the CPU, record module codes, positions and assigned addresses. Check that each program address refers to the intended field terminal and signal.
Power supply and physical inspection
The manual specifies 0.45 A typical from the internal 5 V rail, 2.5 W typical power loss and approximately 1.5 kg weight. Inspect the S5 power supply together with the rack. Internal supply figures must not be used as instructions to apply external power to arbitrary CPU contacts.
When comparing models and revisions, photograph the operating-system submodule fitted to the original unit. For nearby codes such as 6ES5 944-7UA11, record the application requirements and current memory use. Assess the proposed spare against those records.
Diagnostics and used-unit inspection
Begin PLC troubleshooting by recording the LED state and online diagnostic information. Preserve the initial fault evidence before cycling power, performing an overall reset or changing hardware. Check supply, connections and application conditions before attributing every test failure to CPU hardware.
For a used PLC CPU, inspect the label, memory receptacle, serial connection and operating-system submodule. With used Siemens equipment, document which accessories are supplied and which functions were tested. Verify PG access and required application functions as well as the RUN indication.
For modernization, assess Derell PLC options as a separate engineering project. Inventory the existing I/O, program structure and communication requirements, then map them to the proposed system before deciding the scope of replacement.
Editor's Note
Start with the complete CPU code and operating-system submodule. The CPU 944 marking alone is insufficient. Photograph both the original unit and proposed spare so their identification can be compared directly.
Back up the program, required data blocks and current settings before removal. A fitted memory submodule does not establish that it contains the latest application. Compare it with the running contents.
If communication fails, check the TTY cable, converter and connection arrangement before rejecting the CPU. Where possible, repeat the check with a known working programmer and cable to narrow down the cause.
Inspect the battery holder, connectors and memory receptacle. Photograph any corrosion, leakage residue or bent contacts. Establish the data-retention requirements before removing a battery or module from a working installation.
Do not make an overall reset the first troubleshooting step. Prepare diagnostic records, a backup and a recovery method first. When buying a spare, request the actual test configuration and functions checked rather than relying on a general working-condition statement.
OtomasyonAVM resources and PDF archive
6ES5 944-7UA12 main page · Used Siemens S5 models · S5 manuals and PDF archive
The reference used for this model is the S5-115U A-CPU Gerätehandbuch, 6ES5 998-0UF12, Edition 03. It is in German. The exact 7UA12 specification is on printed page 15-16 / PDF page 468.
Related topics
6ES5 944-7UA11 · 6ES5 944-7UA22 · 6ES5 944-7UB11 · Derell PLC options
Navigation
S5-115U CPU group · SIMATIC S5 · Used Siemens · S5 memory submodules · S5 cables
Siemens and external references
Siemens A-CPU manual – exact 6ES5 944-7UA12 specification, 15-16
RAM and memory-submodule arrangement, section 2.2.2 · Memory banks and operating-system condition, 5-14