6ES5 943-7UB21
Siemens 6ES5 943-7UB21 – SIMATIC S5-115U CPU 943B
Siemens 6ES5 943-7UB21 is a CPU 943B central processor module for the SIMATIC S5-115U, with 48 KB internal RAM and two serial interfaces. The Siemens manual identifies this exact code as CPU 943 with two serial interfaces. When maintaining Siemens S5 and SIMATIC S5 equipment, record the complete 7UB21 suffix and hardware version.
6ES5 943-7UB11 is the single-interface version; the second connection is a key distinction of UB21. A proposed change involving nearby CPUs such as 6ES5 942-7UB11, 6ES5 944-7UB11 or 6ES5 944-7UB21 requires comparison of the program, memory and interface use together.
Memory and Program Preservation
Assess the program memory alongside the installed S5 memory submodule. Do not calculate usable program space by simply adding an external card’s label capacity to the internal RAM. Before PLC programming or debugging, record the current program, system data and memory-card order number.
SI 1 and SI 2 Serial Interfaces
The CPU has SI 1 and SI 2 serial connections. The connection system uses a 20 mA TTY current loop; the manufacturer’s second-interface wiring drawing shows a 15-pin D-sub connector. Verify pin assignments and electrical compatibility when choosing S5 cables and connectors and S5 interface modules.
Check the documented function scope of each port for programmer, operator-panel and SINEC L1 use. The second interface also supports ASCII applications, and the CPU includes a real-time clock. When reviewing existing S5 communication modules and panel wiring, record which connection uses SI 1 and which uses SI 2.
COM DB1 limitation: Siemens lists 6ES5 943-7UB21 from version A01 among the CPUs supported by COM DB1, but explicitly states that the second serial interface cannot be parameterized with COM DB1. Use the manual section for the required communication function when configuring that port.
Timers, Counters and Execution Time
The manufacturer’s table specifies 128 timers, 128 counters and approximately 0.8 µs per binary operation. This instruction time is insufficient to establish the complete program scan time. When comparing S5 CPU models, assess the actual program workload and communication traffic as well.
Installation and Spare-Part Checks
Check the existing S5 rack and chassis and S5 power supply, and record the supply condition, rear connectors and backup battery before replacing the module. Verify the complete order number and application before transferring settings from versions such as 6ES5 943-7UA21 or 6ES5 943-7UA22.
See the Siemens S5 PLC overview for system background and the S5 function modules section for other specialist modules. Include label photographs, hardware version, memory-card code and the purpose of both serial ports when requesting a replacement.
Editor’s Note
The two serial ports are a defining feature of this version. When checking a used unit, test the second port as well if the machine uses it for an operator panel or another device.
Keep 7UB11 and 7UB21 clearly distinguished. Reading a program successfully from a single-interface CPU does not establish suitability for a machine that requires both ports.
Back up the program and system data before handling the battery or memory submodule. Record the installed card’s code and establish the battery condition first.
If the second port does not respond, check its cable, assigned function and configuration. Remember that COM DB1 cannot parameterize this port before diagnosing the CPU as faulty.
Check the date and time where the application uses the CPU clock. Reaching RUN is only part of the check; verify panel communication and the time information used by the machine too.
Documentation and PDF Archive
Browse further S5 documents in our S5-115 PDF archive. The model-specific technical data and interface functions were checked against the Siemens references below.
Related Topics and Nearby Models
6ES5 943-7UB11 · 6ES5 942-7UB11 · 6ES5 944-7UB11 · 6ES5 944-7UB21. Assess program capacity, port requirements and version compatibility together before choosing a replacement.
Siemens S5 Navigation
Used Siemens products · Siemens S5 main page · S5 CPU models · Memory modules · Cables and connectors · Communication modules
External References
Siemens S5-115U Manual – EWA 4NEB 811 6130-02b, Edition 04: exact-model table 15-17 / PDF 545; RAM and architecture 2-10 / PDF 40; interface functions 4-12 / PDF 126; second-port wiring 12-21 / PDF 453.
Siemens COM DB1 – EWA 4NEB 812 6113-01b, German: Table 1.1, page 1-4; 7UB21/A01 support and second-interface parameterization limitation.