invt DA200 servo fault codes 7
INVT DA200 Servo Fault Codes 7
This section covers INVT DA200 servo drive faults related to drive overtemperature, encoder offset-angle testing, homing, inertia identification, synchronization, CANopen PTP position commands and SDO communication.
For CANopen-related faults, check the communication wiring, synchronization timing, heartbeat messages, EDS file, SDO indexes and the drive object dictionary before repeatedly resetting the servo drive.
Er23-0 - Drive Overtemperature Fault
Possible causes:
The ambient temperature around the servo drive may have exceeded the permitted level. The drive may also be operating under excessive load.
Checks and solutions:
Reduce the ambient temperature and improve cabinet ventilation and drive cooling. If the load exceeds the capacity of the existing servo system, use a higher-capacity drive and motor combination. Increasing the ACC/DEC times and reducing the mechanical load can also reduce thermal stress on the drive.
Er25-4 - Encoder Offset Angle Test Fault
Possible cause:
An abnormal condition may have occurred during the encoder offset-angle test.
Checks and solutions:
Make sure the motor shaft can rotate freely and that there is no mechanical obstruction restricting movement. Power the servo drive off and on again, then repeat the encoder offset-angle test.
Er25-5 - Encoder Offset Angle Test Failed
Possible cause:
Current feedback may have shown excessive fluctuation during the encoder offset-angle test.
Checks and solutions:
Reduce the P4.53 parameter value to reduce the current-feedback fluctuation. Power the servo drive off and on again, then repeat the test.
Er25-6 - Homing Out-of-Range Fault
Possible cause:
A physical limit switch or software travel limit may have been reached during the homing process.
Checks and solutions:
Check the P5.10 setting together with the software limits and homing parameters. Correct the settings as required, power the drive off and on again, and restart the homing sequence.
Er25-7 - Inertia Identification Failed
Possible causes:
Mechanical vibration during stopping may continue for more than 3.5 seconds. The acceleration time may be too short, or the inertia-identification speed may be below 150 rpm.
Checks and solutions:
Improve the mechanical rigidity of the machine to reduce vibration. Increase P1.07 to adjust the acceleration time and increase P1.06 to raise the inertia-identification speed.
Er22-3 - Synchronization Signal Timeout
Possible cause:
In interpolation position mode, the time between two consecutive synchronization-frame signals may have exceeded twice the communication cycle time.
Checks and solutions:
Check the communication cable and improve network reliability. Verify that the synchronization source is generating synchronization frames at the correct interval.
Er22-4 - Position Command Buffer Full
Possible cause:
The CANopen PTP position-command buffer may be full.
Solution:
Increase the time interval between PTP position commands so that the servo drive has sufficient time to process the buffered commands.
Er26-0 - CANopen Connection Lost
Possible cause:
The CANopen master has not received a heartbeat message from the slave within the required period.
Checks and solutions:
Check the CANopen communication cable, connectors and network wiring. Make sure the slave device is powered and communicating correctly.
Er26-1 - SDO Index Not Available
Possible cause:
During an SDO read or write operation, the requested index may not exist in the drive object dictionary or may not be supported.
Checks and solutions:
Verify the SDO index and compare it with the drive's EDS file and object dictionary.
Er26-2 - SDO Subindex Not Available
Possible cause:
The requested SDO subindex may not exist or may not be supported by the servo drive.
Checks and solutions:
Check the subindex and verify the corresponding object definition in the EDS file.
Er26-3 - SDO Data Length Error
Possible cause:
The data length used by the SDO read or write command does not match the data length defined for that object in the servo drive's object dictionary.
Checks and solutions:
Adjust the SDO read/write data length so that it matches the length specified for the corresponding object in the drive object dictionary.
INVT DA200 Fault Code Document
+ INVT DA200 Servo Fault Codes (PDF)
Related INVT Servo Pages
+ INVT DA200 Servo Fault Code Index