invt DA200 servo fault codes 4
INVT DA200 Servo Fault Codes 4
This section covers INVT DA200 servo drive faults related to homing settings, point-control travel limits, regenerative braking, analog input overvoltage, EEPROM memory, FPGA hardware, communication cards and motor-to-ground short circuits.
When one of these faults occurs, check the relevant parameter settings, terminal connections and power circuit before repeatedly resetting the servo drive.
Er05-4 - Home Mode Setting Error
Cause:
Parameter P5.10 is set incorrectly.
Solution:
Set P5.10 correctly according to the required homing mode and the drive instructions.
Er05-5 - Point Control Travel Exceed Error
Cause:
In absolute-position mode, the travel value has exceeded the permitted limit. The source document specifies this limit as 231-1.
Solution:
Check the commanded travel range and make sure it does not exceed the specified maximum value.
Er07-0 - Regenerative Discharge Overload Error
Possible causes:
The internal braking resistor may have insufficient power capacity. Motor speed may be too high or deceleration may be too fast. According to the source information, the operating limit of the external braking resistor is restricted to a 10% duty cycle.
Solutions:
Use an external braking resistor with sufficient power capacity. Increase the deceleration time to reduce regenerative energy. Reduce motor speed if necessary. If the regenerative energy exceeds the capacity of the existing system, increase the capacity of the motor, drive or braking system.
Er08-0 - Analog Input 1 Overvoltage Error
Cause:
The voltage applied to analog input 1 exceeds the limit configured in P3.22.
Solutions:
Check P3.22, P3.25 and P3.75 and verify the analog-input terminal connections and actual signal voltages. According to the source document, setting P3.22, P3.25 and P3.75 to 0 disables the related protection function.
Er08-1 - Analog Input 2 Overvoltage Error
Cause:
The voltage applied to analog input 2 exceeds the limit configured in P3.25.
Solution:
Check the P3.25 parameter and the actual signal voltage on analog input 2. Adjust the parameter to the correct value for the application.
Er08-2 - Analog Input 3 Overvoltage Error
Cause:
The voltage applied to analog input 3 exceeds the limit configured in P3.75.
Solution:
Check P3.75 and measure the actual voltage on analog input 3. Adjust the parameter to the correct limit value.
Er09-0 - EEPROM Read/Write Error
Possible causes:
Data stored in the EEPROM may have been corrupted during reading. Electrical interference may also have occurred during the EEPROM write operation.
Solutions:
Power the servo drive off and on again, then retry the operation. This may clear a temporary write error. If the fault persists, the servo drive may need to be replaced.
Er09-1 - EEPROM Data Check Error
Possible causes:
The data read from the EEPROM during power-up may differ from the data that was previously written. The drive DSP software version may also have been updated.
Solutions:
Reset the servo-drive parameters and check the configuration again. If the error remains, the drive may need to be replaced.
Er10-0 - FPGA Hardware Error
Cause:
A hardware fault may have occurred in the FPGA chip or its associated circuitry.
Solutions:
Power the servo drive off and on again. If the condition was temporary, normal operation may resume. If the fault reappears, replace or service the servo drive.
Er10-1 - Communication Card Error
Cause:
A fault may have occurred in the external communication card connected to the servo drive.
Solutions:
Power the system off and on again. If the error continues, check the communication card, its connections and communication with the drive. Replace the communication card if necessary.
Er10-2 - Ground Short-Circuit Error
Cause:
When power is applied, the V or W phase of the motor cable may be short-circuited to ground.
Solutions:
Check the motor cable and terminal connections for ground faults or short circuits. Replace the motor cable if damaged. If the motor insulation is old or suspected to be deteriorated, perform an insulation test.
INVT DA200 Fault Code Document
+ INVT DA200 Servo Fault Codes (PDF)
Related INVT Servo Pages
+ INVT DA200 Servo Fault Code Index