invt DA200 servo fault codes 1

INVT DA200 Servo Fault Codes 1

INVT DA200 servo drive fault codes help identify problems related to the drive power stage, motor wiring, encoder feedback, parameter settings and mechanical load. Instead of simply resetting the fault, the actual cause should be identified and the relevant electrical and mechanical connections should be checked.

This section covers the possible causes and troubleshooting steps for Er01-0 IGBT fault, Er01-1 braking transistor fault and Er02-0 encoder connection fault.

Er01-0 - IGBT Fault

Possible causes:
The actual output current may exceed the permitted value. The servo drive power circuit or IGBT module may be faulty. The U, V and W motor cables may have a short circuit or ground fault. The servo motor may also have damaged windings or an insulation fault.

The U, V and W motor phase connections may be incorrect. Incorrect servo parameters can make the control system unstable. Very short ACC/DEC acceleration and deceleration times during starting or stopping, or a sudden load exceeding the drive capacity, can also cause Er01-0.

Checks and solutions:
Disconnect the motor cables from the servo drive and test the drive under controlled conditions. If Er01-0 remains present with the motor disconnected, the drive power stage may be faulty and the servo drive may require repair or replacement.

Check the motor cables, U-V-W connections and insulation to ground. Check the P0.10 and P0.11 parameter values and reduce them if required by the application. Check the loop-related settings associated with P0.12 to improve system stability.

Increase the acceleration and deceleration times. If the mechanical load exceeds the capacity of the existing servo drive, use a higher-power drive. If the servo motor has damaged windings or insulation, the motor should be replaced.

Er01-1 - Braking Transistor Fault

This fault is associated with the braking circuit on DA200 models rated 7.5 kW and above.

Possible cause:
The braking unit or braking transistor inside the servo drive may be faulty.

Checks and solutions:
Check the braking circuit and servo drive power stage. If the braking transistor is faulty, the drive may require repair or replacement.

Er02-0 - Encoder Fault / Encoder Cable Disconnected

Possible causes:
The encoder may not be connected or the encoder connector may be loose. One of the motor U, V, W connections or encoder A, B, Z signal wires may be disconnected or damaged.

The encoder A/B signal connections may be incorrect. Electrical noise may interrupt encoder communication or corrupt feedback data. An FPGA communication timeout may have occurred, or the encoder type used by the motor may not be supported by the servo drive.

Checks and solutions:
Check the encoder connector and encoder cable. Replace the cable or connector if damaged. Measure the encoder supply voltage and verify that it is within the required range.

Route the encoder cable separately from motor power cables and other high-noise wiring wherever possible. Connect the cable shield to FG/ground according to the installation requirements.

Check the compatibility between the servo motor encoder and the drive using parameter P0.01. Make sure that the servo motor, encoder type and servo drive model are compatible with each other.

INVT DA200 Fault Code Document