This section covers INVT DA180 servo drive faults related to overspeed, drive temperature, position deviation, communication, braking resistor overload, IPM module protection, input phase loss, inertia identification and motor parameter mismatch.
Before resetting a fault, check the listed causes and correct the actual problem. Repeatedly resetting the servo drive without identifying the cause will not solve faults related to the power stage, braking system or mechanical load.
Er-oS - Overspeed error
Cause: Motor speed is too high or the motor has exceeded its allowable speed range.
Solution: Check the speed command and related servo parameters. If the application requires a speed above the motor's operating range, use a motor suitable for the required higher speed.
Er-oH1 - Drive overheating error
Cause: The temperature of the servo drive's IGBT module is too high.
Solution: Check cabinet ventilation and improve cooling. If the load exceeds the capacity of the existing drive, a higher-power servo drive may be required.
Er-oE - Excessive position deviation error
Cause: The position-following deviation between the command and the actual motor position may be too high.
Solution: Check the position-loop gain parameters. If required, increase the position-loop gain or position feedforward gain.
Er-cTE - Communication error
Cause: The communication error rate may be too high or communication may have been interrupted.
Solution: Reduce electrical interference on the communication line. Check the communication cable, connectors and terminal connections.
Er-oT - EEPROM read/write timeout error
Cause: A timeout occurred during EEPROM reading or writing, or the EEPROM may be faulty.
Solution: Replace the servo drive if the fault persists.
Er-bcE - Braking resistor overload error
Cause: The power rating of the internal or external braking resistor may be insufficient for the application.
Solution: Connect an external braking resistor with a higher suitable power rating, or replace the existing resistor with a correctly rated model.
Er-iPo - IPM module error
Cause: The IPM power module has detected an abnormal current condition such as overcurrent or undercurrent.
Solution: Reduce the maximum output torque by decreasing FP0.12. If the application load exceeds the drive capacity, use a higher-power servo drive.
Er-dP - Power supply phase-loss error
Cause: A phase is missing or abnormal in the three-phase input power supply.
Solution: Check the input voltages and power wiring. Tighten any loose terminal or cable connections.
Er-INE - Inertia identification error
Cause: Vibration during stopping may continue for more than 3.5 seconds, acceleration time may be too short, or the inertia identification speed may be below 150 RPM.
Solution: Increase the mechanical rigidity of the system. Increase FP1.07 to extend the acceleration time and increase FP1.06 to raise the identification speed.
Er-DrE - Motor parameter mismatch error
Cause: The FP0.00 motor model or motor parameter setting may be incorrect.
Solution: Check the connected servo motor model and make sure it is compatible with the servo drive. Set FP0.00 according to the correct motor model.