invt DA200 servo fault codes 6

INVT DA200 Servo Fault Codes 6

This section covers INVT DA200 servo drive faults related to drive overload, motor overload, motor temperature, overspeed, speed deviation, forward and reverse position overtravel, hybrid-control deviation and full-closed-loop position errors.

For these faults, the motor-drive combination, U-V-W phase wiring, encoder feedback, mechanical load and speed/position control parameters should be checked together.

Er17-0 - Drive Overload Fault

Possible causes:
The short-term load on the servo drive may be too high. There may be an incorrect U-V-W phase sequence or phase loss in the motor wiring. The encoder or servo motor may also be incompatible with the drive.

Checks and solutions:
Check whether the mechanical load exceeds the drive capacity. Inspect the U-V-W motor wiring, phase sequence and possible phase loss. Confirm that the servo motor, encoder and drive are compatible.

Er18-0 - Motor Overload Fault

Possible causes:
The servo motor may have operated under overload for an extended period, or a short-duration load may have exceeded the motor capacity.

Solution:
Check the mechanical load. If the torque and power requirements exceed the existing servo-system capacity, use a higher-capacity motor and servo drive.

Er18-1 - Motor Overtemperature Fault

Cause:
The motor temperature has exceeded the configured protection level.

Solution:
Check the motor load and operating duty cycle. If the motor capacity is insufficient for the application, use a suitable higher-capacity servo motor.

Er19-0 - Overspeed Fault

Possible causes:
Motor speed may have exceeded the value configured in P4.32. The U-V-W phases may be wired incorrectly. The electronic gear ratio or speed-loop parameters may be incorrectly configured.

The P4.32 value may also be lower than P4.31, which is the maximum speed limit. Electrical interference on the encoder feedback signal may also cause an overspeed condition to be detected.

Checks and solutions:
Check the electronic gear ratio and speed-loop parameters. Verify the U-V-W motor phase wiring. Inspect the encoder connection and feedback signal. If the required machine speed exceeds the motor capability, use a motor with a suitable higher speed rating.

Er19-1 - Forward Overspeed Fault

Cause:
The forward-direction speed feedback may have exceeded the value configured in P4.40 for more than 20 ms.

Checks and solutions:
Check that the encoder is operating correctly and verify that P4.40 is set appropriately for the required forward speed limit.

Er19-2 - Reverse Overspeed Fault

Cause:
The reverse-direction speed feedback may have exceeded the value configured in P4.41 for more than 20 ms.

Checks and solutions:
Check the encoder feedback and verify that P4.41 is correctly configured for the reverse-direction speed limit.

Er19-3 - Incorrect Overspeed Parameter Setting

Cause:
The value of P4.40 may be less than 0, or the value of P4.41 may be greater than 0.

Checks and solutions:
Check the encoder connection and verify the settings of P4.40 and P4.41. Correct any invalid forward or reverse speed-limit settings.

Er20-0 - Speed Deviation Fault

Possible causes:
In modes other than torque control, the difference between actual motor speed and the speed command may have exceeded the value configured in P4.39. The U-V-W phases may be reversed or the motor cable may be disconnected.

The mechanical load may be too heavy and cause the motor to stall. The servo drive may not have sufficient capacity, the speed-loop parameters may be incorrect, or P4.39 may be set too low.

Checks and solutions:
Check the motor phase sequence and motor wiring. Inspect the conveyor, chain, table or other moving mechanism for physical limits, jamming or excessive load.

Check the speed-loop parameters and confirm that the selected servo system has sufficient capacity. Increase P4.39 if required. According to the source information, setting P4.39 to 0 disables speed-deviation fault detection.

Er21-0 - Forward Position Overtravel Fault

Possible cause:
In position-control mode, the forward limit switch may have been activated, or the accumulated feedback pulse value may have exceeded P0.35.

Checks and solutions:
Check the forward-limit switch signal and verify that P0.35 is correctly configured for the actual machine travel limit.

Er21-1 - Reverse Position Overtravel Fault

Possible cause:
In position-control mode, the reverse limit switch may have been activated, or the accumulated feedback pulse value may have exceeded P0.36.

Checks and solutions:
Check the reverse-limit switch signal and verify that P0.36 is correctly configured.

Er22-0 - Hybrid Control Deviation Too Large

Possible causes:
System response may be too slow, causing the accumulated pulse count to exceed the value configured in P4.33. The mechanical load may be too high and cause motor stalling. The pulse input frequency may exceed the motor's maximum speed capability.

A sudden step change in the position-command input may also exceed the value configured in P4.33.

Checks and solutions:
Check whether the conveyor, chain, table or other mechanism has reached a physical limit or encountered an obstruction. Adjust the position-loop gain, speed feedforward gain or P4.33. Check the electronic gear ratio and reduce sudden changes in the position command.

Er22-1 - Full-Closed-Loop Position Deviation Fault

Cause:
During full-closed-loop control, the position deviation between the linear encoder feedback and motor encoder feedback may have exceeded the value configured in P4.64.

Checks and solutions:
Check the mechanical connection between the motor and load. Inspect the connection between the linear encoder and servo drive. Verify that P4.60, P4.61 and P4.62 are configured correctly.

Er22-2 - Position Increment Overflow Fault

Cause:
The single position command converted through the electronic gear ratio may have exceeded the limit shown in the source document as 231-1.

Checks and solutions:
Reduce the amount of change in a single position command. Adjust the electronic gear ratio to an appropriate range to prevent position-command overflow.