This section covers encoder-related faults on INVT DA200 servo drives, including feedback deviation, parity errors, CRC errors, frame errors, communication timeouts, FPGA communication faults and low battery voltage conditions on multi-turn encoders.

When an encoder fault occurs, do not rely only on resetting the servo drive. Check the encoder connection, signal cable, shielding, grounding, supply voltage and compatibility between the motor encoder and servo drive.

Er02-1 - Encoder Feedback Error Too Large

Possible causes:
There may be a large deviation in the encoder feedback data. A mechanical connection problem, such as slippage between the encoder shaft and motor shaft, may be present. Encoder-related parameters may also be incorrect.

Checks and solutions:
Check the encoder connections and make sure that the encoder is correctly aligned with the motor and that the mechanical connection is secure. Check the encoder-related parameters, especially P0.01. Inspect the feedback circuit for unstable or incorrect feedback signals.

Er02-2 - Encoder Parity Error

Possible causes:
A data error may have occurred during the encoder parity check. Electrical noise or deterioration of the encoder cable may cause this fault.

Checks and solutions:
Inspect the encoder cable and connectors for damage or interference. Check the cable shielding and grounding and reduce nearby noise sources. Verify that the parity settings used by the system are correct.

Er02-3 - Encoder CRC Check Error

Possible causes:
The CRC (Cyclic Redundancy Check) may have failed during encoder data transmission. Communication data may have been corrupted by electrical interference or noise.

Checks and solutions:
Check the shielding and grounding of the encoder cable. Replace the cable if it is physically damaged or deteriorated. Inspect the communication path and identify possible sources of electrical interference.

Er02-4 - Encoder Frame Error

Possible cause:
A framing problem may have occurred during encoder data transmission, preventing the data packet from being received correctly by the servo drive.

Checks and solutions:
Check the encoder signal cable and all connection points for damage or loose connections. Make sure that shielding and grounding are correct and reduce interference around the encoder wiring.

Er02-5 - Encoder Short Frame Error

Possible cause:
The encoder may have transmitted a data frame shorter than expected, resulting in incomplete communication.

Checks and solutions:
Check the encoder output and verify that the encoder is operating correctly. Inspect the cable for broken conductors, short circuits, damaged insulation or poor connections.

Er02-6 - Encoder Timeout

Possible causes:
Encoder data may not have been received within the expected time. Electrical interference on the communication line may also cause a timeout.

Checks and solutions:
Check the encoder power cable and connections and confirm that the encoder is receiving the correct supply voltage. Route the encoder signal cable away from motor power cables and other high-noise wiring wherever possible.

Er02-7 - FPGA Timeout

Possible causes:
A communication timeout may have occurred between the FPGA (Field-Programmable Gate Array) and the encoder. There may also be a fault in the FPGA circuit or a delay in data transmission.

Checks and solutions:
Inspect the data communication between the encoder and FPGA. Check the signal cables and connectors and make sure all connections are secure. If the wiring is normal and the fault remains, the drive electronics may require inspection.

Er02-8 - Encoder Low Battery Voltage Alarm

Possible cause:
When a multi-turn encoder is used, the external encoder battery voltage may have fallen to approximately 3.0 V to 3.2 V.

Checks and solutions:
Check the battery connection in the encoder cable. Measure the external encoder battery voltage. If the voltage is below 3.2 V, replace the battery.

According to the source document, the battery should be replaced while the drive is powered to prevent loss of encoder position data. Follow the manufacturer's battery replacement and electrical safety procedure when carrying out this operation.

Er02-9 - Encoder Battery Low Voltage Alarm

Possible cause:
When a multi-turn encoder is used, the external encoder battery voltage may have fallen to approximately 2.5 V to 3.0 V.

Checks and solutions:
Check the battery connection and encoder cable. Measure the battery voltage. If the voltage is below 3.0 V, replace the battery.

The source document states that the battery should be replaced while the drive remains powered; otherwise encoder position data may be lost. Follow the manufacturer's procedure when replacing the battery.