Gd20 Fault Codes 2

INVT GD20 Fault Codes 2

This section covers INVT Goodrive20 (GD20) faults related to phase loss, overtemperature, communication, current detection, motor auto-tuning, EEPROM memory, PID feedback, braking, keypad communication and ground faults.

SPI - Input Phase Loss

Possible cause:
One of the R, S or T input phases may be missing, or the incoming three-phase supply may be unstable or severely unbalanced.

Checks and corrective actions:
Check the incoming mains supply, phase voltages and input wiring. Inspect fuses, contactors and terminal connections for loose connections or phase loss.

SPO - Output Phase Loss

Possible cause:
One of the U, V or W motor phases may be missing, or the motor load may have a serious three-phase imbalance.

Checks and corrective actions:
Inspect the VFD output wiring, motor terminal connections and motor cable. Check the motor windings for continuity and phase balance.

OH1 - Rectifier Overtemperature

Possible causes:
The cooling air path may be blocked, the cooling fan may be damaged, ambient temperature may be too high, or the GD20 may have been operating under overload for too long.

Checks and corrective actions:
Clean the cooling path and check the fan. Replace the fan if necessary. Reduce the ambient temperature and check whether the drive has been operating under excessive current or overload. If the fault remains, the power stage or control hardware may require service inspection.

OH2 - IGBT Overtemperature

Possible causes:
The IGBT power stage may be overheating because of poor cooling, high ambient temperature or excessive motor load.

Checks and corrective actions:
Check the cooling fan and air path. Reduce the ambient temperature and inspect the motor current and mechanical load. Persistent OH2 faults may require inspection of the power unit.

EF - External Fault

Possible cause:
A digital input assigned to the external-fault function has become active.

Checks and corrective actions:
Check the external-fault input and the sensor, relay or machine device connected to that input.

CE - RS485 Communication Fault

Possible causes:
The baud rate may be incorrect, communication wiring may be faulty, the device address may be wrong, or strong electromagnetic interference may be affecting the RS485 network.

Checks and corrective actions:
Verify the baud rate and communication address. Check RS485 wiring, terminal connections and shielding. Route communication cables away from motor and power cables where possible.

ItE - Current Detection Fault

Possible causes:
A control-board connection may be poor, the internal auxiliary power supply may be abnormal, or the Hall current sensor / current-detection circuit may be faulty.

Checks and corrective actions:
Check internal connectors and wiring. If the fault remains, the Hall current sensor and main control board may require service inspection or replacement.

tE - Motor Auto-Tuning Fault

Possible causes:
The motor capacity may not match the GD20 rating. Motor nameplate parameters may be entered incorrectly. The identified motor values may differ significantly from the expected values, or the auto-tuning process may have timed out.

Checks and corrective actions:
Check motor and drive sizing. Enter the rated motor voltage, current, frequency, power and speed according to the motor nameplate. If the selected tuning method requires an unloaded motor, disconnect the mechanical load and repeat auto-tuning. Check the motor wiring before starting the procedure again.

According to the source information, also verify that the upper frequency limit is set above two-thirds of the motor rated frequency.

EEP - EEPROM Fault

Possible causes:
A read/write error may have occurred while accessing control parameters, or the EEPROM memory may be damaged.

Checks and corrective actions:
Try resetting the drive with STOP/RST. If the fault returns, the main control board may require service or replacement.

PIDE - PID Feedback Fault

Possible causes:
The PID feedback signal may be disconnected, or the feedback source may be missing or faulty.

Checks and corrective actions:
Check the PID feedback cable, sensor and signal source. Verify that the feedback level is within the range expected by the drive.

bCE - Braking Unit Fault

Possible causes:
The braking circuit or braking switching device may be faulty. The external braking resistor may also be undersized for the application.

Checks and corrective actions:
Inspect the braking unit and its wiring. Confirm that the braking resistor resistance and power rating are suitable for the GD20 model, machine inertia and braking duty.

END - Operating-Time Limit Reached

Possible cause:
The accumulated operating time of the GD20 has exceeded the configured internal running-time limit.

Checks and corrective actions:
Review the relevant operating-time setting and adjust it only where appropriate for the application or service requirement.

PCE - Keypad Communication Fault

Possible causes:
The keypad may be disconnected or poorly connected. The keypad cable may be too long or exposed to strong interference. A fault may also exist in the keypad or main-board communication circuit.

Checks and corrective actions:
Check the keypad cable and connectors. Reduce nearby electromagnetic interference. If the problem continues, inspect the keypad and control-board communication hardware.

UPE - Parameter Upload Error

Possible causes:
The keypad may be offline or poorly connected, the cable may be affected by strong electrical noise, or the communication circuit between the keypad and main board may be faulty.

Checks and corrective actions:
Check the keypad connection and cable. Remove or reduce interference sources. If communication remains unstable, inspect the keypad and main control hardware.

DNE - Parameter Download Error

Possible causes:
The keypad connection may be poor, the cable may be too long or exposed to strong interference, or a data-storage error may exist in the keypad.

Checks and corrective actions:
Inspect the keypad cable and surrounding electrical environment. Recreate or retransmit the parameter data stored in the keypad. If the fault remains, the keypad hardware may require service.

ETH1 - Ground Short-Circuit Fault 1

Possible causes:
The GD20 output may be short-circuited to ground, or the current-detection circuit may be faulty.

Checks and corrective actions:
Check the motor and U-V-W output cables for insulation failure or a short circuit to ground. Verify the motor connections. The Hall current sensor or main control board may require inspection if the wiring is normal.

ETH2 - Ground Short-Circuit Fault 2

Possible cause:
The configured motor power may differ significantly from the actual motor connected to the GD20.

Checks and corrective actions:
Review and, if necessary, re-enter the motor parameters. Make sure the P2 motor-power parameters match the actual motor nameplate data.