Dear colleagues, hello

You are in the Inovance MD series VFD Drive Fault Codes and Solutions section.

It appears that there are multiple issues that could be causing the motor not to rotate, the DI terminals to be disabled, the motor speed to be always low in CLVC mode (Close loop vector), the AC drive to report overcurrent and overvoltage frequently, and Err17 to be reported upon power-on or running. Here are some suggested steps to address each issue:

If the motor does not rotate after the AC drive runs, first check the motor and motor cables. If they are normal, check and re-set the motor parameters in the AC drive. If the problem persists, check the cable between the drive board and control board for poor contact. If that is not the issue, it is possible that the drive board is faulty and needs to be replaced.

If the DI terminals are disabled, check and reset the parameters in group 04. Also, check the external signal cables and confirm that the jumper bar across OP and +24V is properly connected. If the problem persists, the control board may be faulty and technical support should be contacted.

If the motor speed is always low in CLVC mode, check the encoder and encoder cable for proper connection and contact. If they are normal, replace the PG card. If the issue is not resolved, technical support should be contacted.

If the AC drive reports overcurrent and overvoltage frequently, first check and re-set the motor parameters or perform motor auto-tuning. Also, set the proper acceleration/deceleration time. If the problem is due to load fluctuations, technical support should be contacted.

If Err17 is reported upon power-on or running, check whether the soft startup contactor is picked up. If it is not, check whether the contactor cable is loose, whether the contactor is faulty, or whether the 24V power supply of the contactor is faulty. If none of these issues are found, technical support should be contacted.


Err01: Drive unit protection . detail >>
Err02: Acceleration over-current. detail >>
Err03: Deceleration over-current. detail >>
Err04: Overcurrent at constant speed. detail >>
Err05: Acceleration over-voltage. detail >>
Err06: Deceleration Over-voltage. detail >>
Err07: Overvoltage at constant speed. detail >>
Err08: Control power supply fault. detail >>
Err09: Undervoltage. detail >>
Err10: AC drive overload. detail >>
Err11: Motor overloaded. detail >>
Err12: Power input phase loss . detail >>
Err13: Power output phase loss. detail >>
Err14: Module overheat (IGBT) . detail >>
Err15: External fault (digital input). detail >>
Err16: Communication fault . detail >>
Err17: Encoder fault (some model Contactor) . detail >>
Err18: Current detection fault .detail >>
Err19: Motor auto-tuning fault. detail >>
Err20: Pulse wheel encoder fault. detail >>
Err21: EEPROM read-write fault (some model encoder fault). detail >>
Err22: AC drive hardware fault. detail >>
Err23: Short circuit to ground . detail >>
Err24: ---
Err25: Data storage fault. detail >>
Err26: Accumulative running time reached. detail >>
Err27: User-defined fault 1 . detail >>
Err28: User-defined fault 2 . detail >>
Err29: Accumulative power-on time reached. detail >>
Err30: Load lost . detail >>
Err31: Software overcurrent (some model PID feedback lost during running). detail >>
Err32: Battery overspeed running. detail >>
Err33: Overspeed fault. detail >>
Err34: ---
Err35: ---
Err36: Contactor fault. detail >>
Err37: Brake fault. detail >>
Err38: Contact conglutination. detail >>
Err39: Motor overheated. detail >>
Err40: Pulse-by-pulse current limit ( Elevator running conditions not conformed). detail >>
Err41: Motor switchover fault during running. detail >>
Err42: Speed feedback error too large speed deviation. detail >>
Err43: Motor over-speed . detail >>
Err44: ---
Err45: Motor overheat. detail >>
Err46: ---
Err47: ---
Err48: ---
Err49: ---
Err50: ---
Err51: Initial position fault. detail >>
Err52: ---
Err53: ---
Err54: ---
Err55: DSP communication protection. detail >>
Err56: ---

-------------------------

+ Inovance MD Series VFD Fault main page >

+ MD Series Fault codes Page 1 >

+ MD Series Fault codes Page 2 >

+ MD Series Fault codes Page 3 >

+ MD Series Fault codes Page 4 >

+ MD Series Fault codes Page 5 >

+ MD Series Fault codes Page 6 >

+ MD Series User manuals >

-------------------------

+ VFD Main page

+ Servo System main page

+ Inovance Fault code

+ Inovance contact -

Refine Search