Siemens 6ES7 193-1FH30-0XA0 — ET 200L Two-Tier Screw Terminal Accessory
The Siemens 6ES7 193-1FH30-0XA0 is a two-tier supplementary terminal with screw connections for the 16-channel SIMATIC ET 200L arrangement. It adds termination points to the main terminal block, keeping additional field wiring close to the station. It is a separate accessory from the base that carries the electronic block.
The 16-channel designation identifies the wiring arrangement the part serves. It does not provide 16 additional inputs or outputs. 1FH30 is a wiring accessory: it does not process signals, switch loads or execute a PLC program. The installed electronic block determines the station’s actual I/O function.
What the additional terminal rows provide
ET 200L supplementary terminals allow the two-wire arrangement to be completed for three- or four-wire connections with the appropriate hardware. This provides extra termination points for auxiliary conductors serving sensors and other field devices. The change concerns the wiring layout; it does not increase electronic I/O capacity.
A key detail in the Siemens manual is that the terminals within each tier are internally interconnected. Individual positions along a row must not be treated as isolated signal terminals. Connecting different potentials to the same common row can create a short circuit. Establish the purpose of each row from the circuit drawing and terminal markings. Internal bridging within each tier does not mean that the two tiers are connected together.
The supplementary terminal is not a power supply. It neither generates a voltage nor provides current limiting by itself. Supply distribution, common return paths and circuit protection must be considered as part of the complete electrical design.
Product identification and the main terminal block
Manufacturer: Siemens. Complete order number: 6ES7193-1FH30-0XA0. Product group: SIMATIC DP / ET 200L supplementary terminal. Arrangement: 16 channels, two tiers. Connection method: screw terminals. The Siemens data sheet revised on 16 March 2017 gives an approximate weight of 170 g; this is not a packed shipping weight.
The 6ES7 193-1CH00-0XA0 TB 16L is the 16-channel main terminal block with screw connections. 1CH00 and 1FH30 perform different jobs: the base carries the electronic block, while the supplementary terminal supplies additional wiring rows. When selecting ET 200 connection components, check the physical position and purpose of the part as well as its order number.
The channel count of this accessory does not establish the electrical characteristics of a digital input module or the load capacity of a digital output module. Voltage, current and wiring limits must be checked against the relevant base, electronic block and connected field equipment.
Differences between similar order numbers
6ES7 193-1FH20-0XA0 is the 16-channel single-tier screw version. 6ES7 193-1FH60-0XA0 has two tiers with spring terminals, also for the 16-channel arrangement. 6ES7 193-1FL30-0XA0 uses two tiers and screw connections but belongs to the 32-channel arrangement.
These differences affect the number of rows, termination method and physical arrangement. Compare the complete part number and mounting layout before choosing a replacement. Sharing the ET 200 name does not make a terminal from another ET 200 system mechanically interchangeable with ET 200L hardware.
Installation and screw-terminal connections
Before disconnecting conductors, place the machine in a safe condition, isolate the relevant supplies and verify the absence of voltage. Record the existing connections and row assignments so that each wire can be returned to its intended point. For shared potential rows, use the circuit drawing and terminal markings rather than relying on wire colour alone.
A tightened screw does not automatically mean a sound connection. The conductor must be prepared correctly, fully seated and secured using the specified tightening torque. An insufficiently tightened connection can cause contact problems; excessive force can damage the screw, clamping element or conductor. Follow the applicable Siemens instructions for conductor cross-section, stripping length, ferrules and tightening torque.
Arrange cables and connectors so they do not apply continuous pulling or bending forces to the terminals. Nearby panel components, cable ducts and service clearances also affect access during maintenance. Remove loose wire strands and address damaged insulation before restoring power.
Commissioning and fault investigation
This supplementary terminal requires no separate program, firmware download or network address. PROFIBUS communication and station configuration belong to the relevant ET 200L electronics. The functions of communication interfaces should be distinguished from the electrical termination provided here.
After replacement, check conductor matching, terminal retention and common-row connections first. Carry out continuity measurements on an isolated circuit, taking account of connected electronics that may influence the readings. Once power is restored, observe voltage distribution and field-device behaviour under controlled conditions. A changing bit in the engineering software does not, by itself, confirm that every connection is sound.
Editor’s note: When several sensors stop working together, include their common wiring in the investigation. Voltage at the output of a DIN rail power supply does not prove that it reaches every field device. Likewise, intermittent operation of connected relays and sockets may involve a cable termination or shared return connection as well as the electronic module. These examples help separate possible causes; no single symptom proves that this accessory has failed.
Discolouration, melting, cracks, damaged screw threads or poor conductor retention require more than simply tightening the terminal again. Investigate the cause before replacing the part, otherwise the same damage may recur. For used equipment, review the order number, physical condition and supplied components together. Testing and availability should be assessed from the particular product listing.
PDF documents and user manuals
Use the Siemens ET 200 user manuals page to locate documentation. The existing Siemens IK PI 2007 ET 200 catalogue lists 6ES7193-1FH30-0XA0 on page 5/214. This is a general catalogue; consult section 7.6 and Appendix A of the ET 200L system manual for the terminal arrangement and component identification.
Related topics
For an overview of station operation, see About ET 200. Other hardware is listed in the ET 200 product range, while the Siemens automation section covers the wider product group.
Send product enquiries through OtomasyonAVM’s Siemens contact page. Field observations can be shared in accordance with the community rules. Information about the site is available under About OtomasyonAVM.
Navigation
ET 200 terminal blocks · ET 200 products · PDF documents and manuals · Siemens automation · Siemens product enquiries