6ES7 156-0AA01-0XA0

Siemens 6ES7 156-0AA01-0XA0 – PROFIBUS DP / AS-i Link Fieldbus Coupler

Siemens 6ES7 156-0AA01-0XA0 is a SIMATIC DP/AS-i Link fieldbus coupler connecting AS-Interface field devices to a PROFIBUS DP network. It transfers sensor and actuator information between the machine's field network and the higher-level controller. By linking AS-Interface with PROFIBUS DP, it allows both networks to serve the same PLC application.

The unit operates as a PROFIBUS DP slave and an AS-i master. It manages the connected AS-i devices while appearing as a single PROFIBUS station to the upper-level controller. Within a Siemens distributed I/O system, its purpose is to exchange information between these two communication layers.

AS-i Capacity and Communication Performance

The 6ES7 156-0AA01-0XA0 supports up to 31 AS-i slaves. Siemens specifies a 5 ms AS-i cycle with 31 slaves and a maximum PROFIBUS DP rate of 12 Mbit/s. The supported AS-i master profile is M2. Selection should use this model's 31-slave capacity rather than the 62-device A/B addressing capabilities associated with later AS-i equipment.

The AS-i cycle is only one part of the machine's overall response time. PLC execution, upper-level network timing and the behaviour of the connected equipment also affect the delay between detecting a signal and producing an action. For time-sensitive applications, assess the complete signal path. The industrial communication section provides background on the roles of different automation networks.

Typical Role on a Machine

A conveyor provides a useful example: distributed photoelectric sensors, inductive sensors and limit switches can feed suitable local AS-i modules. Before choosing a replacement coupler, record each field module's I/O arrangement and its role in the project, as well as the number of connected devices.

A conventional sensor's electrical output and an AS-i communication interface are different specifications. A sensor without an integrated AS-i interface requires a suitable local input module. For contactor or valve control, check the load voltage, current and auxiliary supply against the selected AS-i output module.

Power Supply and Connections

The electronics use a 24 V DC supply, with a permitted range of 20–30 V DC stated in the manual. The AS-i network requires its own suitable supply arrangement. Having a working DIN rail power supply for the electronics does not establish that the AS-i line is correctly powered. When selecting power supplies and circuit protection, assess the electronics and field loads separately.

The connection arrangement comprises two 12-pole PROFIBUS/power connectors and one 4-pole AS-i connection. Siemens lists 6ES7 194-5AA00-0XA0 as the AS-i cable connection accessory. Before ordering, establish which plugs, T connectors and protective caps are required. When selecting connectors and cables, compare the pin assignment and intended function as well as the physical shape.

IP66/IP67 Housing and Installation

Manufacturer specifications give an IP66/IP67 protection rating, an operating temperature range of -25 to +60 °C, dimensions of 205 × 80 × 57 mm and a weight of approximately 800 g. Installation planning should allow additional space for the mating connectors and cable routing.

Protection in service depends on the assembled installation. Inspect connector seals, unused connection covers and the address-switch cover, particularly when evaluating an older unit. A damaged seal or missing cap can matter more than the rating printed on the label. Review grounding, cable screening and mechanical fastening together.

Addressing, Configuration and Fault Finding

The coupler's PROFIBUS station address and the AS-i slave addresses are separate settings. Record both before replacement. Compare the device definition or GSD file, I/O mapping and field-device configuration with the existing project. When reviewing ET 200 communication interfaces, check the actual protocol and hardware requirements of each product.

The BF indicator reports a PROFIBUS fault, ASi POWER FAIL identifies an AS-i supply problem, and CONFIG ERROR indicates a configuration issue. First establish which side of the coupler is affected. Record the LED condition alongside PLC diagnostics and any operator-panel message. Where SCADA history is available, comparing the fault time with process events can help make intermittent problems easier to investigate.

Editor's Advice

Before requesting a replacement, photograph the label and every connection, then record the PROFIBUS address and AS-i device list. Specify whether the enquiry also needs connectors, T pieces or covers. After replacement, verify the actual input and output assignments if communication returns but the machine behaves incorrectly. An online network and correctly mapped process signals are separate checks.

Technical Documents and Related Topics

The principal reference for this model is the Siemens Distributed I/O System DP/ASi Link, Edition 3 – EWA 4NEB 710 6055-02b manual. Visit the Siemens ET 200 manuals and PDF documentation page for the document archive. The Siemens ET 200 overview explains the wider system, while the ET 200 connection modules section covers related hardware.

Siemens > SIMATIC S7 > ET 200 > Connection Modules