6ES7 153-4AA00-0XB0
Siemens 6ES7 153-4AA00-0XB0 – ET 200M IM 153-4 PN Interface Module
Siemens 6ES7 153-4AA00-0XB0 is the IM 153-4 PN interface module for connecting an ET 200M station to PROFINET IO. Part of the SIMATIC ET 200 family, it exchanges field input and output data with the supervising controller. It is an I/O interface rather than a programmable CPU; the control program runs in the connected PLC.
Its role in an ET 200M station
ET 200M allows suitable S7-300 modules to form a distributed I/O station away from the main control cabinet. The IM 153-4 PN provides that station’s network connection. For example, sensors and valves in a separate machine section can be wired to a local cabinet, with their control data exchanged over PROFINET with the main PLC.
When selecting digital input modules or digital output modules, verify ET 200M compatibility using the complete order number. The broader ET 200 family name does not establish compatibility between ET 200M, ET 200S, ET 200SP and ET 200pro components.
Module capacity and I/O address space
The interface supports up to 12 suitable S7-300 modules. This is the physical module limit. Address requirements and supported module functions must also be checked when planning the station.
Address-space distinction: Siemens’ product description states 200 bytes of input and 200 bytes of output data, while the same product’s technical table specifies 192 input bytes and 192 output bytes for addressing. Use 192 bytes per direction when planning usable I/O capacity, and validate the configuration in the engineering project.
Analog channels and digital signals do not consume address space in the same way. Before adding another module, review its data requirements alongside the existing address allocation rather than relying only on the number of vacant positions.
PROFINET ports and network layout
An integrated two-port switch with two RJ45 connections allows the station to connect to PROFINET and continue the connection to another device in a suitable line topology. PROFINET IO communication operates at 100 Mbit/s. Two ports do not establish two independent controller interfaces or automatic network redundancy.
This model uses PROFINET IO. Other IM 153 variants use PROFIBUS, so the network protocol is an essential selection criterion. Our industrial communication section provides background on network structures and terminology.
Micro Memory Card and device name
The 6ES7 153-4AA00-0XB0 requires a SIMATIC Micro Memory Card. Siemens specifies a minimum capacity of 64 KB. On this version, the PROFINET device name is stored on the card. This function should not be confused with storing a CPU user program.
The station’s device name must match its project configuration. Record the existing name and card details when preparing a replacement. Operation without a memory card, available on the AA01 version, does not apply to AA00. These similar order numbers should not be assigned identical capabilities.
Power supply, dimensions and installation space
Rated supply is 24 V DC, with a permissible range of 20.4–28.8 V DC and specified maximum current consumption of 600 mA. Protection rating is IP20. Housing dimensions are 40 × 125 × 118 mm, in width × height × depth order.
When sizing the power supply, account for I/O modules, connected sensors and output loads as well as the interface. Select the DIN rail power supply according to the complete station’s load distribution. Allow additional cabinet space for Ethernet plugs, cable bends and access to the front cover.
Engineering and replacement checks
Review the complete interface order number, firmware, module sequence and applicable hardware catalogue or GSDML file in the STEP 7 project. Certain signal modules depend on specific GSDML versions. Physical installation alone does not establish that the current project supports a particular module.
Before replacing hardware, photograph the station, record module positions and addresses, and check the memory card and project backup. Include the connection components and backplane connections in the inspection.
A station-loss message on an HMI panel or SCADA system does not, by itself, establish an interface hardware failure. Check the supply, cabling, device name and project match together. This helps distinguish configuration issues from a faulty component before selecting a replacement.
Manuals and related topics
For installation, wiring and commissioning details, consult the ET 200M documents available through our Siemens ET 200 manuals and PDF documentation page. Shared manuals cover several revisions, so check whether each section applies to AA00 or AA01.
Related topics: Read about the Siemens ET 200 system and explore our PROFIBUS FAQ for additional background on the product family and communication options.
Editor’s note: The AA00 order number and mandatory Micro Memory Card are important replacement details. When reviewing a unit, confirm its label, firmware version and whether the required card is included in the proposed supply.