6ES7 143-2BH00-0AB0

Siemens Main Menu  |  SIMATIC S7  |  Siemens ET 200  |  PDF Manuals

6ES7 143-2BH00-0AB0 - Siemens SIMATIC DP ET 200R-H Handling Module

Series: SIMATIC DP ET 200R
Product type: IP65 metal-housed handling module; 8 fixed DI + 8 parameterizable DI/DO
Order number: 6ES7143-2BH00-0AB0

6ES7 143-2BH00-0AB0 is the rugged ET 200R-H handling module in the Siemens ET 200 distributed I/O family. It provides eight fixed digital inputs plus eight channels that can be parameterized as inputs or outputs. By combining PROFIBUS-DP communication, field power and I/O connections in an IP65 metal housing, it supports direct field connection to a SIMATIC S7 automation system on robot arms, tool couplings and automotive body-production equipment.

Channel arrangement: what 8 DI + 8 DI/DO means

There are 16 process channels in total. Pins 2 and 4 of sockets X0-X3 can be parameterized as DI or DO; the two channels on each socket from X4 through X7 are digital inputs only. The product is therefore not a fixed 8 DI + fixed 8 DO module. Every configurable channel assigned as an output reduces the number available as an additional input.

Each five-pin M12 socket carries two signal channels. When comparing ET 200 digital input modules and ET 200 digital output modules, do not confuse the number of sockets with the number of channels. Each channel configured as an output on X0-X3 can supply a maximum of 0.5 A.

Key technical specifications

Process channels: 16; 8 fixed DI + 8 parameterizable DI/DO.
I/O connections: 8 × five-pin M12x1 sockets.
Bus and power: 2 × 17-pin M23 on X01/X02.
Supply voltage: 24 V DC; permissible range 20.4-28.8 V DC.
Digital inputs: IEC 61131 Type 2; -3...+5 V for signal 0 and +15...+30 V for signal 1.
Input delay: typically 3 ms.
Output current: 0.5 A maximum per channel.
Output group current: 2 A maximum per group up to 55 °C.
Switching frequency: 100 Hz maximum with a resistive load.
Communication: PROFIBUS-DP, 9.6 kbit/s to 12 Mbit/s.
Degree of protection: IP65.
Operating temperature: up to 55 °C.
Dimensions: 54 × 150 × 55 mm; 64 mm high including plugs.
Weight: approximately 780 g.

Outputs have electronic short-circuit protection and an integrated free-wheeling diode for inductive loads. Output short-circuit diagnostics are separated into the X0-X1 and X2-X3 groups. The maximum unshielded cable length for load and sensor signals is 10 m. Assess the communication side together with the ET 200 PROFIBUS interface and network architecture.

Difference between ET 200R-H and ET 200R-W

This order number identifies the ET 200R-H handling module. 6ES7143-2BH50-0AB0 is the ET 200R-W welding version and adds a base opening with the connection arrangement used for welding signals. The housings and basic I/O ratings are similar, but the two versions must not be substituted solely on appearance. Compare the full order number with the Siemens ET 200 system architecture.

Six selection and commissioning checks

1. Confirm configurable-channel direction in the project. The eight channels on X0-X3 may be inputs or outputs; X4-X7 are inputs only. Do not move field wiring before checking channel directions in STEP 7 or the DP-master project. The process image uses two input bytes and one output byte; input and output areas must not be assigned the same address.

2. Calculate output current by group. Although each output is rated at 0.5 A, the total is limited to 2 A per group. Check simultaneous loads and coil inrush separately for X0-X1 and X2-X3 at the 55 °C operating limit. Drive heavier loads through a correctly selected interposing relay or contactor.

3. Separate US1 and US2 functions. US1 supplies electronics and sensors; US2 supplies digital-output loads. On X01/X02, the limit is 9 A per pin for each supply, while the combined US1 + US2 limit is 13 A at 55 °C or 18 A at 45 °C. When designing the ET 200 power supply arrangement and ET 200 power distribution, include every module connected in the loop-through current calculation.

4. Verify PROFIBUS address, GSD and repeater topology. The address is selected by two rotary switches and commissioning requires the correct GSD file. The integrated repeater couples two PROFIBUS segments without reaction between them. The Siemens manual specifies no more than nine ET 200R devices on one branch and no more than 30 m of shielded bus cable per segment. Select ET 200 connection modules and cables against these limits.

5. Do not leave unused sockets open. IP65 applies only when every M12 and M23 connection is correctly tightened and every unused port has the correct protective cap. Damaged sealing surfaces, threads or base seals invalidate the assumption of IP65 protection. Complete missing caps and connectors from the ET 200 supplementary modules and accessories before field use.

6. Read diagnostics together with field feedback. BF indicates a bus fault, SF a group fault, ON the US1 supply and PWR/24 V DC the US2 load supply. CH01/CH02 show repeater-segment activity, while channel LEDs show I/O state. A lit output LED does not prove actuator movement; monitor critical motion through an auxiliary contact or limit sensor in the ET 200 field connection arrangement.

Used-unit inspection

Inspect the metal housing for deformation, the base seal for tears, M12/M23 threads for damage, connectors for oxidation and the address switches for mechanical play. Hardware revision also matters: the manual notes that some M23 signal pins were not connected on earlier revisions. Send the label, hardware revision, close photographs of the ports and present BF/SF LED state through the Otomasyon AVM Siemens contact page for a more reliable compatibility assessment.

Editor’s note

The most misleading shorthand for this model is “8 inputs + 8 outputs.” The correct description is 8 fixed inputs + 8 parameterizable inputs/outputs. Outputs cannot be expected from X0-X3 until the project is configured correctly, and X4-X7 cannot become outputs under any parameter setting. The second critical point is IP65: one open M12/M23 port or a damaged seal removes the practical advantage of a field-mounted module.

PDF manuals and documentation

Consult Distributed I/O Device ET 200R - Release 06/2004 and the exact-model data sheet on the Siemens ET 200 PDF manuals page. The manual documents X0-X7 channel assignments, M12/M23 pin allocation, US1/US2 supplies, PROFIBUS address setting, GSD requirements and BF/SF diagnostics. This page is selection guidance; use the device label, hardware revision, installed project and manufacturer manual as the final authority for wiring and commissioning.