6ES7 195-7HD80-0XA0

Siemens main menu › SIMATIC S7 family › ET 200 › ET 200 manuals

6ES7 195-7HD80-0XA0 — Siemens BM IM/IM Active Bus Module

6ES7 195-7HD80-0XA0 is a BM IM/IM active bus module in the Siemens SIMATIC product family, designed for an extended temperature range. The manufacturer also uses the designation BM IM157. Within ET 200 system architecture, it supports redundant ET 200M arrangements with compatible IM153-2 interfaces. Select the base together with the complete order numbers of the interfaces to be fitted.

Five points to check before selection

1. Exact interface version: Do not match ET 200 communication interfaces using the IM153-2 family name alone. For example, Siemens’ 12/2008 ET 200M compatibility table pairs an IM153-2BA81 configuration with the 7HD80 base and IM153-2BA81 hardware. Record the Siemens S7 hardware project entry together with both interface labels and firmware versions. For an existing station, locate the applicable compatibility-table entry before replacing its base.

2. Mounting rail and bus arrangement: Active bus modules require the special mounting rail for module replacement during operation. Examples include 6ES7195-1GA00-0XA0 and 6ES7195-1GF30-0XA0. When reviewing ET 200 connection modules, check the rail profile and engagement of the side connections. When reserving space for ET 200 additional components, include cabinet width, cable access and the removal sequence in the mechanical layout.

3. Scope of redundancy: The FF Link manual lists this code as the redundant BM IM/IM base. In that system, 7HF80 is BM FDC and 7HG80 is BM FDC/FDC. When comparing ET 200 network interface options, assess interface redundancy and coupler redundancy separately. Include the ET 200 power supply arrangement in that assessment; fitting two interfaces does not remove every possible single point of failure.

4. Limits of replacement during operation: A suitable configuration permits supported modules to be replaced during operation. However, the active bus base itself must only be removed when de-energized. When preparing maintenance procedures for station equipment such as ET 200 function modules, specify whether the part being replaced is an electronic module, interface or bus base. Check the applicable system manual and configuration requirements before starting work.

5. Environment and enclosure: Manufacturer documentation describes this product as suitable for an extended temperature range and uses the term outdoor. Do not treat these descriptions alone as approval for an unenclosed outdoor installation. Compare the permitted conditions for the interfaces, bus base, other modules and cabinet separately. When planning ET 200 power distribution, also account for heat sources and cable routing; ambient temperature alone does not describe conditions inside the cabinet.

Editor’s note

The two details most easily confused are the interface version and which component can be replaced during operation. A hot-swap capability does not authorize removal of the energized bus base. Record the base order number, both interface order numbers and mounting rail together to make future maintenance decisions easier.

PDF and technical documentation

Visit the Siemens ET 200 PDF and user manual library for the documentation guide. In the ET 200M manual, 12/2008, EWA-4NEB780600602-08, pages 44–45 cover compatibility and arrangement, page 115 covers bus module replacement, and page 247 lists order numbers. In the FF Link manual, 03/2015, A5E35651245-AB, see pages 31–33 for redundant installation and page 101 for the component list.

Related topics

Terminal bases • Connection modules • Communication interfaces • Other network interfaces • Power distribution • Additional modules

Otomasyon AVM • Siemens guide

Siemens main menu  |  SIMATIC S7 family  |  ET 200 module categories  |  ET 200 PDF archive