Delta LCSoft is Windows software for supported DVP load-cell modules, covering communication, weighing parameters, zero/calibration and measurement monitoring. Preserve the channel and function differences within DVP Slim load-cell modules. LCSoft configures the weighing module; it does not independently create machine sequencing, filling logic or HMI screens.

LCSoft V1.14 is the latest official central record checked on 15 November 2026. Its listed issue date is 26 December 2022, package size 3.03 MB, and language type multilingual. The official LCSoft V1.14 download follows Delta’s terms/verification flow. The previous official V1.13 record is dated 9 June 2020 and lists 3.02 MB.

Supported modules · PC connection · Calibration and scaling · V1.14 and filtering · PDF manuals

LCSoft, PLC editors and communication tools

Prepare CPU logic in the supported WPLSoft or ISPSoft editor. COMMGR manages PC–PLC channels for the relevant engineering tools. The documented direct LCSoft serial connection is configured in its own Communication Setting menu; do not insert COMMGR as a universal prerequisite. Identify which program writes to which device.

Single/dual channel: DVP01LC-SL and DVP201LC-SL have one load-cell channel; DVP02LC-SL and DVP202LC-SL have two. DVP211LC-SL combines one weighing channel with 2 DI, 4 DO and 1 AO. A common software tool does not give every model the same analogue output or local I/O.

Standalone communication and PLC expansion are separate. Configuring a module through its serial port does not mean every DVP CPU supports its left-side expansion bus. For families such as DVP-SV, DVP-SA2 and DVP-SX2, check the full CPU code, module arrangement and applicable manual. A similar name does not establish DVP LCSoft support for AS/AH weighing modules.

PC connection and serial settings

The LC-SL manual examples identify COM1 as RS-232 and COM2 as RS-485. Select a supported Delta configuration cable or converter according to the module pinout. A similar mini-DIN connector does not establish cable compatibility. RS-232 and RS-485 are different electrical interfaces.

In LCSoft, open Option → Communication Setting and select the actual PC COM port and module settings. Match station address, baud rate, parity, data/stop bits and ASCII/RTU. Defaults in an old example are not evidence of the current settings on a previously configured machine.

Upload means module to PC; Download means PC to module. Uploading current settings when going online can replace the values already in the software. Save the existing PC file separately before reading the intended module. An unintended Download can change weighing and communication parameters.

Load-cell wiring, mV/V and channel selection

For a 4-wire or 6-wire load cell, follow the model diagram for EXC±, SIG±, SEN± and shield. Wire colours can differ by sensor manufacturer. A strain-gauge load-cell signal is not the same input type as a 0–10 V or 4–20 mA transmitter output.

The mV/V characteristic describes sensor sensitivity, not kilogram capacity. An incorrect range affects adjustment and measurement. Check the channel, sensor capacity, excitation/power requirements and mechanical load path together. ADC resolution, transmitted data width and actual weighing accuracy are different specifications.

Zero, tare and calibration

Zero adjustment establishes the empty-scale reference; tare separates container/carrier weight from the net reading; calibration relates known physical weights to digital module values. Taring the display does not correct an incorrect gain or scale.

1. Record existing parameters and PLC/HMI scaling. Confirm the intended channel. Check the platform, sensor and cable, ensure the mechanism is free, and obtain a sufficiently stable unloaded value. Keep test loads within the sensor’s mechanical capacity.

2. Follow the model’s adjustment sequence to establish the unloaded reference. Apply a suitable known reference weight and enter its weight and corresponding digital value in the correct fields. Follow the documented sequence for supported multipoint adjustment. Do not copy another generation’s CR addresses or command values.

3. Transfer settings to the module and complete its required retentive save operation. A saved PC file does not prove that module settings survive power loss. During an allowed shutdown, verify zero and the reference weight after power returns. Keep the parameter file with model and firmware details.

Display units and decimals do not define PLC scaling

LCSoft’s Weight Measurement Unit and Decimal Point settings do not automatically change the module’s digital values. The DVP module manual, PDF 323 explains this distinction. Match the calibration relationship to the PLC/HMI calculation. Changing a “kg” label alone does not convert the raw value between grams and kilograms.

For example, if a project defines 1 kg = 1000 counts, 500 counts represents 0.5 kg. This is an example scale, not a factory constant. Use the correct PLC data type; for 32-bit values held in two 16-bit registers, check word order and signed interpretation. Record the module code, CR address and destination PLC register separately.

Filtering, response time and the V1.14 change

LCSoft V1.14 and module firmware V1.14 are separate versions. The 2022-Q4 newsletter, PDF 86–88 describes new LPF functions for DVP201LC-SL, DVP202LC-SL and DVP211LC-SL. Its K3–K6 filter options require firmware V1.14 or later; installing newer PC software alone does not add these capabilities to older module firmware.

The bulletin covers LPF 5/10/20 Hz and a filter option targeting 50/60 Hz interference, including the 10 ms conversion-time condition in these modes. These settings differ from the older DVP01LC-SL/DVP02LC-SL filter ratios. Filtering can calm the display while affecting filling or high-speed response; do not use it to conceal mechanical friction or poor wiring.

Unstable readings or incorrect values

Check supply power and the model-specific L.V / ERROR state, then sensor/SEN wiring, shielding, cable condition and mechanical binding. Disturbance that appears when a motor/drive starts, loss of serial communication and a consistently incorrect scale are different symptoms. Observe them separately.

If LCSoft reads correctly but the PLC/HMI does not, check net/gross selection, channel, data address, word order and display scaling. A PLC program writing old parameter values each cycle may undo a PC adjustment. Inspect those writes before repeating calibration.

Versions and Windows support

Research identified V1.00, V1.10, V1.11, V1.12, V1.13 and V1.14. V1.00 is documented by Delta EMEA, V1.11 by a manufacturer technical PDF, and V1.13/V1.14 by current official records. V1.10 and V1.12 are tracked separately through historical distributor/listing records; their installer bytes were not verified. This is not claimed to include every intermediate build.

The current OS field lists Windows XP / Vista / 7 (32-bit/64-bit) / 8 (64-bit) / 10 (64-bit). Windows 11 support is not explicitly stated. Multilingual does not independently establish a Turkish interface. Check USB–serial converter driver compatibility and the assigned COM port separately.

PDF manuals, announcements and historical editions

The following seven PDFs are model manuals, installation sheets and manufacturer announcements. They are not presented as a standalone complete V1.14 interface manual. Multilingual documents contain Turkish sections; English manuals are identified by their actual language.

DVP201/202/211LC-SL operation and calibration manual — Wiring, control registers, tare/stability, filtering and calibration examples. Chapter 5 / PDF 39–50 covers adjustment. The source server’s 2025/10 folder is not the document date. English; 2022-10-03; 4th revision; 50 pages; 1.94 MB.

DVP01/02/201/202/211LC-SL installation and wiring sheet — Turkish/English and Chinese sections; installation, 4/6-wire sensor connections and DVP211LC-SL I/O drawings. Not a full software user manual. Multilingual; Turkish/English sections; 2023-03-07; 2 pages; 0.69 MB.

DVP module manual: five LC-SL models and LCSoft interface — Chapter 12 / PDF 274–327: model differences, CR tables, software interface, calibration and troubleshooting. PDF 323 distinguishes display units/decimals from module digital values. Back cover: 2023/07/31; metadata: 2024/01/09. The source filename’s 20240226 is not treated as its edition date. Not presented as the latest 2026 DVP manual. English; Rev.01; internal revision table 2023-11-30; 559 pages; 14.27 MB.

LCSoft V1.11 manufacturer technical announcement — Documents V1.11 and communication-protocol display/online-change functionality. The announcement spells the model DVP202LC-S; it has not been silently changed into another full model code. English; 2015-08-03; 2 pages; 0.15 MB.

2022-Q4 manufacturer newsletter: LCSoft V1.14 and LC module firmware — Relevant section PDF 86–88: load-cell firmware V1.14, new LPF settings and LCSoft V1.14. Preserved as the full 125-page newsletter, which also contains other products. Its planned November 2022 availability statement is separate from the central record dated 2022-12-26. English; 2022-Q4; 125 pages; 5.55 MB.

DVP201/202/211LC-SL historical operation manual — Historical reference for older screens/register arrangements. Its 48 pages are distinct from the 50-page 2022 Rev.04. Not the default reference for newer LPF functions. English; 2019-02-20; 2nd revision; 48 pages; 1.12 MB.

DVP02LC-SL historical multilingual instruction sheet — Turkish section — Historical electrical, wiring and register reference; Turkish section PDF 15–19. Its legacy resolution wording must not be generalized to all current LC models; read with the applicable model/edition. Multilingual; Turkish/English sections; 2010-09-24; Rev.01; 19 pages; 0.67 MB.

Editor’s note

Do not erase calibration as the first response to an inaccurate scale. Read and back up existing settings first. Keep the module label, firmware, sensor capacity, mV/V and channel together so the earlier setup can be reconstructed.

Inspect the unloaded mechanism as well as the reading. Binding feet, frame contact or a pipe carrying part of the load can make a healthy sensor read incorrectly. Tare does not repair a mechanical fault. Investigate load transfer if a known weight gives different results at different positions.

Distinguish Upload from Download when going online. Read the device first and check the transfer direction. If PLC logic repeatedly rewrites settings, inspect those writes instead of recalibrating again and again.

A kg label does not complete scaling. How many counts represent the reference weight? Record that relationship and compare it with HMI multiplication/division. Check zero, an intermediate load and an appropriate operating-range reference rather than trusting one matching point.

Do not hide instability by maximizing filtering. Correct wiring, shielding, supply and mechanical vibration, then select filtering appropriate to the required response. The V1.14 LPF feature has separate software and module-firmware requirements.

Complete the module’s retentive-save operation as well as saving the PC file. At a suitable shutdown, recheck the same reference weight after power returns. Preserve verified settings with their software/firmware versions; do not make factory reset the first diagnostic action.

Related topics

Delta DVP Slim load cell modules · Delta DVP01LC-SL · Delta DVP02LC-SL · Delta DVP201LC-SL

Delta DVP202LC-SL · Delta DVP211LC-SL · Delta DVP expansion modules · Delta DVP PLC series

Delta DVP-SV · Delta DVP-SA2 · Delta DVP-SX2 · Delta DVP-SV2

Delta PLC software · Delta WPLSoft · Delta ISPSoft · Delta COMMGR

Delta Plc Cables · Load cell how it works? · What is load cell and its types? · What is strain gauge load cell?

External references

Official Delta LCSoft download centre · Delta EMEA DVP02LC-SL / LCSoft V1.00 announcement · Delta Turkey DVP202LC-SL and LCSoft training