Delta DVP60ES00R2
Delta DVP60ES00R2 | PLC with 36 inputs and 24 relay outputs
The Delta DVP60ES00R2 is a main unit in the original Delta DVP-ES series. It runs on 100–240 V AC and has 36 digital inputs rated at 24 V DC and 24 relay outputs. In packaging and conveyor machines, it reads sensors, runs the machine sequence and switches outputs. For the basics, see what a PLC does and how the PLC CPU works.
Inputs, relay outputs and panel wiring
Inputs are X0–X43 and outputs are Y0–Y27. Delta uses octal addresses for X and Y, so X10 comes after X7. See how PLC inputs and outputs work when matching the wiring diagram to the project addresses.
An inductive sensor can detect a metal part, while a photoelectric sensor can detect a product passing on a conveyor. Check the S/S common terminal against Delta’s wiring diagram for the chosen PNP or NPN output and sinking or sourcing arrangement. For a two-wire sensor, account for off-state leakage current.
The output relay contacts switch an external load supply. Delta specifies 2 A per output and 5 A total per common terminal. Check the load limits for coil current and switching frequency. Follow the terminal diagram for common groups and fuse protection. A suitable suppression diode across a DC coil reduces voltage spikes at the relay contacts.
The case fits a 35 mm DIN rail. Mains power connects to L/N. Check protective grounding and the separate 24 V DC input wiring against Delta’s diagram. The built-in I/O is digital. Applications that need analog inputs or outputs call for a compatible expansion module or a CPU with analog I/O.
Programming software and cables
WPLSoft is the starting point for uploading the existing ladder program from the PLC, editing it and monitoring it online. Use ISPSoft with a version that supports the original DVP-ES target. Select ES as the CPU type. Keep the original WPLSoft project and check addresses and instructions before writing a converted project to the PLC. See the PLC programming guide for the general workflow.
For COM1 (RS-232), use the UC-PRG020-12A with a USB-equipped PC or the UC-MS020-01A with a native RS-232 port. Delta’s older instructions also list DVPACAB215 and DVPACAB230. After installing the USB cable driver, select the Windows COM port in WPLSoft. See the Delta PLC cable guide for cable options.
COM2 (RS-485) can communicate with a compatible HMI or drive. For a Modbus connection, match the station address, baud rate, parity and communication format at both ends. Our industrial communications guide explains how interfaces and protocols fit together.
Related Delta models
The DVP60ES00T2 has the same I/O count with transistor outputs. The DVP40ES00R2 is a smaller ES model with 24 inputs and 16 relay outputs. The DVP60ES200R is a later ES2 model with 36 inputs and 24 relay outputs. For a move to ES2, check terminal layout, output commons, serial ports, expansion modules and program compatibility. The DVP20EX00R2 is an original EX model with fewer digital points and built-in analog I/O.
Editor’s note
When buying used, ask for a clear photo of the complete label. Listings often confuse 00R2 and 200R.
Back up the program with WPLSoft before taking the old unit out. Record the HMI and drive communication settings as well.
On the bench, check the POWER, RUN and ERROR LEDs. Then test inputs one by one and verify that you can upload the program through COM1.
If an output LED lights but the load stays off, check the common supply for that group and test the relay contact with a suitable test load.
If the machine needs high-speed pulse output, verify the pulse specification of a suitable transistor-output model. The R2 uses mechanical relay contacts.
PDFs and internal references
Delta DVP PLC files · DVP-ES/EX wiring and installation instructions (PDF)
Delta PLC › Delta DVP PLC series › Delta DVP-ES
External references
Delta DVP-ES manufacturer’s page · Delta DVP-PLC programming manual · Delta PLC/HMI Cable Selection Guide, section 1.2