Delta DVP28SS211T
Delta DVP28SS211T | DVP-SS2 PLC with 16 inputs and 12 NPN outputs
The Delta DVP28SS211T is a compact 28-point PLC CPU in the Delta DVP-SS2 series. Its 16 digital inputs and 12 NPN transistor outputs connect sensors, valves and drive controls to one CPU. The nominal supply is 24 VDC, with a range of 20.4–28.8 VDC. It suits sequence control in packaging equipment, conveyors and small machines.
Digital inputs, NPN outputs and high-speed signals
The inputs are grouped as X0–X7 and X10–X17. The 24 VDC inputs support sink or source wiring. Wire the group’s S/S common according to the PNP or NPN type of the inductive sensor. For high-speed counting, Delta specifies 20 kHz for X0–X3 and 10 kHz for X4–X7. The manual lists 1 kHz for X10–X17 and notes that the actual rate depends on PLC scan time.
The outputs use supply terminals UP0/ZP0 for Y0–Y7 and UP1/ZP1 for Y10–Y13. Connect the load between the positive supply and the corresponding Y terminal, and check the 24 VDC auxiliary supply for each group against the wiring diagram. The resistive load limits are 0.5 A per point and 3 A per common. Use appropriate suppression for coils and a suitably rated interposing relay or contactor for AC loads.
The Y0–Y3 transistor outputs support pulse rates up to 10 kHz. For pulse-command motion, check the drive’s required frequency and input circuit. Program capacity is 8,000 steps. The right-side bus accepts compatible DVP Slim digital and analog modules. Delta specifies up to 480 total I/O points with digital expansion. For analog measurements, select the appropriate module and channel signal range.
WPLSoft, ISPSoft and programming cables
Develop the PLC program in WPLSoft or ISPSoft. Select the DVP-SS2 CPU family in the project. For a PC connection, use the CPU’s COM1 RS-232, 8-pin mini-DIN port. On a USB-equipped PC, install the UC-PRG020-12A driver and check the COM number in Windows. On a PC with a hardware RS-232 port, use a DB9-to-mini-DIN cable such as the UC-MS020-01A.
For ISPSoft, select the serial driver and the same COM number in COMMGR. In WPLSoft, match the PLC communication settings. COM2 RS-485 supports Modbus ASCII/RTU communication with HMIs, drives and other field devices. Check the station address, rate, data format and bus termination. When troubleshooting serial communication, first identify the port and protocol in use.
Editor’s Note
When buying a used unit, check the T suffix on the label, the mini-DIN socket, the right-side expansion connector and the DIN rail clip.
Even with the POWER light on, measure the 24 VDC supply at the CPU terminals while the load switches. If it drops, check the power supply and connections first.
Back up the project and required retained values before changing the program. Test the machine’s restart state after a power cycle.
Test the Y0–Y7 and Y10–Y13 groups separately with a suitable load. If an output LED lights and the load stays off, check the UP/ZP supply.
If the PC cannot connect, start troubleshooting with the driver, COM number, cable and serial settings. Check shielding and grounding on the field bus.
Related models
The DVP28SS211R has the same I/O count with relay outputs. The DVP14SS211T has 8 inputs and 6 NPN outputs. The DVP14SS211R has 8 inputs and 6 relay outputs. The DVP12SS211S has 8 inputs and 4 PNP outputs. Check the output type, terminal arrangement and program I/O addresses before replacement.