Delta DVP20PM00DT

Delta DVP20PM00DT | Two-axis 500 kHz motion controller

The Delta DVP20PM00DT is a two-axis motion CPU in the Delta DVP-PM family. It takes a 100–240 VAC supply. Delta’s catalogue lists two independent 500 kHz differential pulse outputs and 8 digital inputs and 8 digital outputs. It provides X–Y position control with compatible servo drives or stepper motor drives.

Axis terminals, inputs and DT output type

FP0±/RP0± and FP1±/RP1± are the differential pulse pairs for the two axes. Select the pulse format that matches the drive. For servo motor direction and motion scaling, check the drive’s command input, electronic gear ratio and pulses per unit of travel. Linear and circular interpolation provide coordinated X–Y motion.

The LSP/LSN inputs connect to limit switches. The DOG inputs serve functions such as homing. The A/B and PG differential inputs accept signals up to 200 kHz. Match the line-driver encoder or handwheel wiring to the input type and signal voltage.

On the DT variant, Y0–Y7 are general-purpose transistor outputs. The instruction sheet rates them at 5–30 VDC, up to 10 kHz, with resistive load limits of 0.5 A per point and 4 A per common. Use the dedicated FP/RP pairs for axis commands. When switching a valve or interposing relay coil, check its load current and suppression.

PMSoft, programming cable and field communications

Use Delta PMSoft for the PLC and motion program. The software edits the main program, motion subroutines and G-code paths. Connect the PC to COM1 RS-232. Delta’s DVP-PM cable guide lists the UC-PRG020-12A for a USB-equipped PC and UC-MS020-01A for a native RS-232 port. The guide illustrates neighbouring PM models. Check the DT port and cable pinout against the installation sheet.

Identify the Windows COM number assigned to the USB-to-RS-232 adapter. In PMSoft versions that use COMMGR, select the appropriate serial driver for that port. For a direct connection, select Motion Controller as the target. For Modbus field communications on COM2 RS-485, match the station address, baud rate and data format. The optional DVP-FPMC card provides Ethernet and CANopen connectivity for the DVP-PM family. Where a card is fitted, check its hardware and project settings.

Editor’s Note

When buying a used unit, check the 00DT suffix on the label. Inspect the terminal covers, COM1 socket and DIN rail clip.

Back up the PMSoft project and axis settings before replacement. Record the MANU/AUTO switch position and BAT.LOW indicator status.

Check both conductors of each differential FP/RP pair when testing pulses. Test Y0–Y7 separately with a suitable load.

Run the first axis test at low speed on a safe test setup. Verify the positive and negative limits, homing and motion scaling.

When troubleshooting, check the COM1 connection first, then the signals going to the drive. Inspect pulse cable shielding and cabinet grounding.

Related models and documents

The DVP20PM00D offers two axes and general-purpose relay outputs. The DVP20PM00M is the three-axis 20PM model. The DVP10PM00M has four independent pulse axes. The DVP-FPMC is a PM family communications card. Compare axis count, Y output type and project support before replacement.

Delta Automation · Delta PLC · Delta DVP PLC series · DVP expansion modules · Delta DVP PLC files

DVP-20PM instruction sheet (TR / EN / Chinese) · PMSoft user manual (EN) · Delta PLC/HMI cable selection guide (EN)