Delta DVPACAB7E10
Delta DVPACAB7E10
Delta DVPACAB7E10 is a 1-metre, 50-pin I/O external-terminal connection cable. It carries field signals between AH10PM-5A or AH15PM-5A motion-control modules and the appropriate terminal board. Select the module, cable and terminal board as a complete combination.
UC-ET010-15B designation and connectors
The manufacturer hardware manual shows DVPACAB7E10 together with the Delta UC-ET010-15B code. The cable selection guide specifies a female MDR50-to-female MDR50 arrangement. Provide the existing cable marking, both connector shapes and complete connected-device codes when ordering.
Verified module-to-terminal combinations
The manufacturer specifies UB-10-IO24C / DVPAETB-IO24C for Delta AH10PM-5A and UB-10-IO34C / DVPAETB-IO34C for Delta AH15PM-5A. The cable connects to the module's CN1 external I/O port. Using the same cable with both modules does not make their terminal boards functionally interchangeable.
50 contacts do not mean 50 independent I/O channels. Obtain pulse-output, input, common and unused-pin functions from the relevant module drawing. Review terminal options under Delta AH external terminals.
Pin functions depend on the module
The cable guide identifies pin 1 as C3 for AH10PM-5A and Y0.11 for AH15PM-5A. Do not combine the two module tables into a universal connection diagram. Follow connector viewing direction, the pin-one marking and terminal-board labels together.
Obtain input levels, output type, pulse frequency and load limits from the module and terminal documentation. Do not present these as current or frequency ratings of the cable itself. Compare signal and common connections against the machine's electrical drawings.
Differences from 7D10, 13B and other cables
Delta DVPACAB7D10 and Delta UC-ET010-13B belong to a separate 36-pin connection group. Delta UC-ET010-33B uses a DB37 connection format. Distinguish these from DVPACAB7E10's 50-pin MDR arrangement.
DVPACAB7A10, DVPACAB7B10 and DVPACAB7C10 are similarly named I/O cables with their own module-to-terminal combinations. Check those combinations separately. Matching length or brand alone does not establish electrical compatibility.
Installation and field testing
Plan the 1-metre route through ducts and turns, allowing for maintenance access. Avoid sharp bends beside connectors and crushing beneath covers. Align connectors with module and field power disconnected, and confirm that retainers close fully.
Review the application under Delta AH temperature / motion modules and Delta AH expansion modules. Check field and system power alongside Delta AH power supplies. Begin testing with one input or output, then complete every signal group used by the application.
PDF and connection drawings
Start document selection at Delta PLC accessories files. In the 2019 PLC/HMI Cable Selection Guide, printed pages 2-25–2-26 / PDF pages 124–125 identify module-to-terminal combinations. Figure 15, printed page 2-39 / PDF page 138 shows the MDR50 arrangement and the different pin functions of both modules.
Editor's Note
Order with both connected-device codes, not the cable alone. Keep AH10PM with IO24C and AH15PM with IO34C in the same record. Physical connector fit is insufficient reason to try a different terminal board.
Inspect connector exits and retainers on a used cable. Look for crushed insulation, loose housings and added splices. Do not use tape pressing against a broken latch as a permanent installation.
Measure continuity with both ends disconnected from equipment. Follow pin numbering from the viewing direction in the manufacturer drawing. Avoid bridging adjacent contacts with probes or guessing connections from connector appearance.
If pulse signals disappear, investigate more than broken conductors. Check plug seating, common connections, routing and the terminal side too. A continuity beep alone does not demonstrate a sound signal at the actual operating speed.
Complete testing under controlled machine conditions. Verify that inputs reach their intended addresses and outputs reach the correct field devices. Establish a test arrangement that prevents unexpected motion and record the result in the maintenance log.
Related topics
Browse parent groups under Delta AH I/O cables and Delta PLC accessories, and device documentation under Delta PLC and HMI manuals.
External references: Delta PLC/HMI Cable Selection Guide — 2019, English · Delta AH Motion Controller Hardware Manual — English.