Delta VFD-E Fault codes

Delta VFD-E fault codes and troubleshooting

Hi everyone,

This page is part of a two-part guide to Delta VFD-E fault codes, alarm messages and basic troubleshooting procedures. Fault and alarm messages are shown on the drive's digital keypad display. The five most recent faults can be read from the keypad or through communication. After clearing the cause of a fault, it is recommended to wait approximately 5 seconds before resetting the drive from the keypad or an input terminal.

OC: Over Current
The drive has detected an abnormal increase in output current.

- Verify that the motor power is suitable for the AC motor drive output rating.
- Check the U/T1, V/T2 and W/T3 motor terminals for short circuits.
- Inspect the wiring between the drive and motor for short circuits or ground faults.
- Check for loose motor and drive connections.
- If the acceleration time is too short, increase the acceleration time.
- Check the motor and mechanical system for excessive load or mechanical binding.
- If the fault remains after the wiring, motor and load have been checked, the drive may require technical inspection.

OV (OU): Over Voltage
The DC bus voltage has exceeded the maximum allowable value.

- Verify that the input voltage is within the rated AC motor drive input voltage range.
- Check the power supply for possible voltage transients or fluctuations.
- Motor regeneration during deceleration can increase the DC bus voltage. In this case, increase the deceleration time or use an appropriate brake resistor and braking unit if required.
- Ensure that the required braking power remains within the specified limits.

oH1 / oH2: Overheating
The drive or heat sink temperature has exceeded the permitted operating range.

- Verify that the ambient temperature is within the specified operating range.
- Make sure that the ventilation openings are not blocked.
- Remove dust, dirt and foreign material from the heat sink fins.
- Check the cooling fan and clean it if necessary.
- Provide sufficient clearance around the drive for proper panel ventilation.

LU: Low Voltage
The DC bus voltage has fallen below the minimum permitted value.

- Verify that the input voltage is within the AC motor drive's rated input voltage range.
- Check the motor and mechanical system for abnormal loading conditions.
- On three-phase models, check the R-S-T input supply and make sure that there is no phase loss.

oL: Drive Overload
The AC motor drive has detected an excessive or prolonged output current.

- Verify that the motor is not overloaded.
- Reduce the torque compensation setting in Pr.07.02 if necessary.
- Make sure that the drive power rating is suitable for the application.
- If the drive is undersized, consider using the next suitable drive rating.

NOTE: Under the specified operating conditions, the drive can withstand approximately 150% of rated current for up to 60 seconds.

oL1: Electronic Overload (Internal Electronic Overload Trip)

- Verify that the motor is not overloaded.
- Check the electronic thermal overload setting.
- Verify that the motor rated current parameter is correctly entered.
- Reduce the motor load if the operating current is too high.
- Make sure that the drive and motor ratings are suitable for the application.
- Check Motor Rated Current – Pr.07.00 and confirm that the drive output current does not continuously exceed the configured value.

oL1 generally requires the motor load, actual operating current and electronic thermal protection settings to be evaluated together.

oL2: Motor Overload

- Reduce the motor load.
- Check the machine for mechanical binding or abnormal load conditions.
- Adjust the over-torque detection settings to appropriate values in Pr.06.03 to Pr.06.05.

bb: External Base Block

bb does not necessarily indicate an internal drive fault. It indicates that the drive output has been blocked by an external control command.

- When the external B.B input is active, the AC motor drive output is turned off.
- Deactivate the external B.B input to allow the AC motor drive to operate again.
- Check the external control circuit if B.B is active unexpectedly.
- Refer to Pr.08.07 for the Base Block timing settings where applicable.

ocA: Over-current During Acceleration

- Check for a short circuit or poor insulation at the motor output wiring.
- If the torque boost / torque compensation is too high, reduce Pr.07.02.
- If the acceleration time is too short, increase the acceleration time.
- Check for excessive motor load or mechanical binding.
- If the drive is undersized for the application, a higher rated drive may be required.

ocd: Over-current During Deceleration

- If the motor is decelerating too quickly, increase the deceleration time.
- Check for abnormal or rapidly changing mechanical load during deceleration.
- Inspect the motor output cables for short circuits or insulation problems.
- If required by the application, check the braking system and braking resistor selection.

ocn: Over-current During Constant Speed Operation

- Check the motor and output wiring for short circuits or ground faults.
- Check for a sudden increase in motor load or mechanical binding.
- Verify the motor rated current and compare it with the setting in Pr.07.00.
- Check that the operating frequency and motor load are suitable for the application.
- If the drive continuously operates near or above its rated current, verify that the drive is correctly sized.

EF: External Fault

An external device or control circuit has activated an input configured as an External Fault signal.

- Check the external fault input and its wiring.
- Identify the external device or condition that generated the fault signal.
- Verify the configuration of the multifunction input terminal.
- After the external fault condition has been removed, give the drive a RESET command.

EF is not necessarily generated by an internal over-current, over-voltage or over-temperature condition. It indicates that an external fault signal has been received by the drive.

GFF: Ground Fault

- Check the motor output terminals and make sure that none of the output phases are grounded.
- Inspect the motor cables for damaged insulation or leakage to ground.
- Check the motor itself for an insulation failure.
- Inspect the IGBT power module if the ground fault remains after the motor and wiring have been disconnected and checked.

NOTE: The drive's short-circuit and ground-fault protection is intended to protect the drive. It does not replace appropriate electrical shock protection for personnel.

cFA: Auto Ramp Fault

- Check the wiring and connections between the AC motor drive and motor.
- Check the relevant acceleration and deceleration settings and adjust them if necessary.
- Check the torque compensation setting in Pr.07.02.
- Verify that the power supply voltage is within the drive's rated input voltage range.
- Check the motor and mechanical load for conditions that prevent the automatic ramp function from operating normally.

CE--: Communication Error
A communication problem has been detected between the AC motor drive and the RS-485 master device.

- Check the RS-485 wiring for loose connections, reversed polarity or incorrect terminal connections.
- Verify that the communication protocol and device address are correctly configured.
- Check the baud rate, data format, parity and stop-bit settings on both devices.
- Verify that the same communication settings are used by the drive and the master device.
- Check the checksum or communication frame format where applicable.
- Inspect the RS-485 cable routing and shielding if electrical noise is suspected.

For detailed communication parameter information, refer to the corresponding Delta VFD-E communication section and parameter group in the user manual.

CODE: Software Protection Failure

If the drive displays a message such as "Software protection failure – Return to factory", an internal software, memory or protection-system problem may have been detected.

- Cycle the power only after confirming that it is safe to do so.
- If the error remains, do not repeatedly attempt to reset or operate the drive.
- Contact the manufacturer, distributor or qualified technical service for further diagnosis.

This type of internal error generally cannot be corrected through normal user parameters.

AErr: Analog Signal Error
The drive has detected a problem related to the analog input signal or ACI circuit.

- Check the wiring of the ACI analog input.
- Make sure that all analog input connections are secure and free from corrosion or damage.
- Check the analog signal cable for cuts, broken conductors or poor shielding.
- Verify that the applied analog signal is within the configured input range.
- Check the related analog input parameters and signal type settings.
- If the wiring and signal source are correct but the error remains, the analog input circuit may require technical inspection.

An unstable or incorrect analog reference can cause inaccurate speed commands or loss of the expected control signal.

Delta VFD-E Fault codes (pdf)

+ VFD-E Fault Codes – First Page >

+ VFD-E Fault Codes – Second Page >

+ VFD-E User Manuals >

-----------------

++ Delta Second-Hand Main Page

+ VFD Main Page

* The user manuals, commissioning suggestions, fault codes and troubleshooting recommendations provided on this page are not binding. The information and documents above are open to improvement and, in some areas, may still require improvement. As the Otomasyon Mall Community, we welcome your suggestions and contributions. If you have field experience or practical information that could help make these products easier to use, please do not hesitate to share it with us. 22.07.2013