CHE100
CHE100
CHE100 is an older INVT open-loop-vector drive. In INVT's wire-drawing case, a CHE100-004G/5R5P-4 drives the main drawing motor while a separate CHF100 drives the winder. Sharing a production line does not make their parameter files or control cards interchangeable.
Role on a drawing line
The main drive sets drawing speed; the winder adjusts its speed to maintain material tension. The actual CHE100 duty depends on the installed machine's control diagram. INVT's sugar-mill case describes large CHE100 drives in a parallel arrangement; that special cabinet architecture does not apply to every small frame.
Choosing a replacement
Record the full CHE100 code, motor voltage and current, speed reference, any parallel power units and braking equipment. CHF100 and CHF100A are different control generations; do not transfer a program merely because the brand or kW figure is similar.
Software and connectivity
INVT lists CHE100 among the ranges supported by INVT Studio monitoring software over serial connection. It reads, compares and monitors drive parameters. See INVT VFD Software for its role; check the installed port and firmware before connecting.
Manuals and documents
Find the documentation topics for this equipment group on INVT VFD Documents.
Use INVT user manuals, checking the complete model code.