what is IP Protected?

IP protection ratings describe how effectively an electrical or electronic enclosure protects against access to hazardous parts, solid foreign objects and the harmful effects of water ingress. The classification is defined by IEC 60529, one of the widely used IEC standards for electrical equipment.
In simple terms… an IP code tells you what the enclosure of a device is designed to keep out. The first number deals mainly with fingers, tools, solid objects and dust; the second number deals with water. A device that can survive splashing water is not automatically suitable for immersion, and a device tested for immersion is not automatically approved for powerful wash-down jets.
How do you read an IP rating?
A basic IP code consists of the letters IP followed by two characteristic numerals. For example, in IP65, the first numeral 6 describes protection against solid foreign objects and dust, while the second numeral 5 describes protection against water jets. The two numerals should be read independently rather than treated as a single overall durability score.
The IP system is often called Ingress Protection in industrial practice, while IEC 60529 formally describes the system as the IP Code. The purpose of the code is not to say that one product is generally “better” than another, but to state which enclosure protection tests it satisfies.
X and 0 do not mean the same thing. In an IPX7 marking, the first characteristic numeral is not specified in that code, while the water protection level is 7. In IP6X, the dust protection level is specified but a water protection numeral is not stated. By contrast, a numeral 0 explicitly indicates that no protection is provided for that particular characteristic.
IEC 60529 can also use additional letters after the numerals to provide information about protection against access to hazardous parts or other specified conditions. When such letters appear on a product, the complete marking and the manufacturer's documentation should be read together.
What does the first IP digit mean?
0 — No specified protection: the enclosure does not provide a defined degree of protection against access or solid foreign objects under this part of the IP classification.
1 — Objects 50 mm and larger: protection is provided against large solid foreign objects. This level is also associated with restricting access to hazardous parts with the back of a hand.
2 — Objects 12.5 mm and larger: protection is provided against objects approximately finger-sized and against access to hazardous parts with the standard test finger. This is the solid-object protection level used in IP20.
3 — Objects 2.5 mm and larger: protection is provided against larger tools, wires and similar objects of the specified size. An IP30 enclosure, for example, uses this level but has no specified water protection.
4 — Objects 1 mm and larger: protection is provided against solid foreign objects such as wires of the specified size. This does not mean that the enclosure is dust-tight.
5 — Dust-protected: some dust may enter the enclosure, but not in a quantity or location that would interfere with satisfactory operation or safety. For this reason, IP54, IP55, IP56 and IP57 should not be described as completely dust-tight.
6 — Dust-tight: under the specified IEC test conditions, dust ingress is not permitted. This is the highest solid-object/dust numeral in the basic IEC 60529 IP classification.
What does the second IP digit mean?
0 — No specified water protection: an enclosure such as IP20, IP30, IP40, IP50 or IP60 has no water protection claim under the second numeral.
1 — Vertically falling water drops: protection is provided against vertically falling drops under the defined test conditions.
2 — Dripping water with the enclosure tilted: protection is provided against vertically falling water drops while the enclosure is tilted by up to 15° from its normal vertical position during the test.
3 — Spraying water: protection applies to water sprayed at angles up to 60° from the vertical under the defined IEC test arrangement.
4 — Splashing water: water splashed against the enclosure from any direction must not produce harmful effects under the specified test conditions.
5 — Water jets: the enclosure is tested against water jets from different directions. This is the water protection level used in IP55 and IP65.
6 — Powerful water jets: the enclosure is subjected to a more demanding water-jet test than numeral 5. This is the water level used in IP56 and IP66. It should not be interpreted as permission to use any pressure washer at any pressure, temperature or distance.
7 — Temporary immersion: the enclosure is tested for temporary immersion under standardized depth, pressure and time conditions. It is commonly summarized as temporary immersion around one metre for 30 minutes, but the exact IEC test arrangement also depends on enclosure dimensions.
8 — Continuous immersion: protection is intended for immersion conditions more severe than numeral 7. The applicable depth, duration and operating conditions are specified by the manufacturer and must be checked for the particular product. IP68 does not define one universal immersion depth for every device.
9 — High-pressure, high-temperature water jets: IEC 60529 includes protection against demanding high-pressure and high-temperature jet-cleaning conditions. This is a different test from immersion.
Common IP ratings in industrial equipment
IP20: protects against solid foreign objects 12.5 mm and larger and restricts finger access to hazardous parts, but provides no water protection. Many industrial electronic products intended for installation inside a control cabinet use IP20 construction.
IP30: protects against solid foreign objects 2.5 mm and larger but provides no specified protection against water. It is not dust-tight.
IP40: protects against solid foreign objects 1 mm and larger. The second numeral 0 means there is no specified water protection.
IP50: is dust-protected but has no specified protection against water. Limited dust ingress can still be permitted provided it does not interfere with satisfactory operation or safety.
IP54: is dust-protected and protected against splashing water from any direction. It is not dust-tight and should not automatically be described as waterproof.
IP55: is dust-protected and protected against water jets. The change from IP54 to IP55 affects the water test; the first digit remains 5, so the enclosure does not become dust-tight.
IP56: is dust-protected and protected against powerful water jets. Because the first digit remains 5, limited dust ingress may still be permitted under the standard's criteria.
IP57: is dust-protected and tested for temporary immersion. It is neither a complete dust-tight claim nor a declaration that the device can operate indefinitely underwater.
IP60: is dust-tight, but the second numeral 0 means that no water protection is specified. A high dust rating therefore does not automatically make a product suitable for wet locations.
IP65: is dust-tight and protected against water jets. It is widely used on industrial equipment exposed to dust and water spray, but the rating alone does not prove suitability for every outdoor environment.
IP66: is dust-tight and protected against powerful water jets. This is a more demanding water-jet condition than IP65, but it is not an immersion rating.
IP67: is dust-tight and protected against the effects of temporary immersion under the defined test conditions. It does not mean unlimited underwater operation and does not automatically establish resistance to the powerful jet test associated with IP66.
IP68: is dust-tight and intended for continuous immersion under conditions specified for the particular product. There is no single IP68 depth or duration that applies to every manufacturer and every enclosure.
IP69: combines dust-tight construction with protection against high-pressure, high-temperature water jets under the applicable IEC test conditions. The jet-cleaning test is not the same as an immersion test.
IP69K: is associated with the ISO 20653 protection-code system for electrical equipment in road vehicles. The K-designated requirements in ISO 20653 are special vehicle-related requirements and should not simply be treated as another name for IEC 60529 IPX9. Always check which standard is stated in the manufacturer's documentation.
Is IP67 always better than IP66?
No. The water numerals do not represent one simple ladder in which every higher number automatically includes every lower test. IP66 addresses powerful water jets, while IP67 addresses temporary immersion. These are different exposure conditions and different test methods.
The same principle applies when comparing IP68 with water-jet ratings. If an application requires resistance to both powerful wash-down and immersion, look for a product carrying the relevant multiple ratings, such as IP66/IP67, or documentation explicitly confirming both test conditions.
A product should therefore be selected according to the actual exposure: dust, rain, splashing, hose-down cleaning, temporary flooding, permanent immersion or high-temperature pressure washing. The largest number is not automatically the correct choice for every installation.
Using IP ratings in industrial automation
PLCs and variable frequency drives inside cabinets: many PLC systems and AC drives and VFDs are designed with an IP20 enclosure because they are intended to operate inside a suitable electrical cabinet. In this case, the protection rating of the complete cabinet can be much higher than the rating of the electronics installed inside it.
Putting an IP20 VFD inside a sealed enclosure does not end the design process. Heat dissipation, internal temperature, ventilation, derating, mounting clearances and condensation must also be considered. A very high enclosure IP rating can create a thermal problem if the heat generated by the equipment cannot be removed correctly.
HMI front and rear protection: an industrial HMI panel may have a high IP rating on its front face while the rear electronics have a lower rating. The front rating normally depends on correct panel cut-out dimensions, gasket installation, mounting surface and tightening method. Do not assume that the entire HMI has the same IP protection as its front bezel.
Sensors in the field: an IP67 pressure sensor can have a well-sealed housing while its electrical connection or mating plug requires separate consideration. The sensor's process-pressure rating is also a completely different specification from the IP rating of its external enclosure.
Connectors and cables: the stated IP protection of industrial sensor connectors often applies only when the correct mating connector is fully engaged and properly tightened. An open socket, missing sealing cap, damaged O-ring or cable gland used with the wrong cable diameter can reduce the protection of the complete installation.
Control panels: the finished enclosure is a system. Doors, gaskets, cable glands, pushbuttons, displays, fans, filters and other panel components all influence the final degree of protection. Installing a component with a lower or unverified rating into an enclosure can compromise the protection originally provided by the empty cabinet.
For low-voltage switchgear and controlgear assemblies, enclosure protection also has to be considered together with the applicable assembly requirements. Our IEC 61439 guide covers the broader context of low-voltage control and distribution assemblies.
Does IP65 automatically mean suitable for outdoor use?
No single IP rating can answer every outdoor-use question. IP65 gives useful information about dust ingress and water jets, but outdoor equipment may also be exposed to ultraviolet radiation, high and low temperatures, salt, corrosion, condensation, icing, chemicals, mechanical impact and long-term weathering.
For example, an enclosure may successfully pass an IP65 water test but still use a plastic material unsuitable for prolonged sunlight, or a metal finish unsuitable for a corrosive coastal environment. Outdoor suitability therefore requires both the IP rating and the manufacturer's environmental specifications.
What does an IP rating not tell you?
An IP code is primarily an enclosure-protection classification. By itself, it does not establish chemical resistance, UV resistance, salt-spray resistance, operating-temperature range, mechanical impact resistance, EMC performance, electrical insulation performance or resistance to internal condensation.
An IP rating also does not mean that equipment is approved for an explosive atmosphere. Explosion protection, functional safety, electrical product safety and other requirements are covered by separate standards and conformity schemes. They should be evaluated independently within the relevant industrial standards.
Does an IP rating remain valid after installation?
Only if the installation preserves the conditions required for the rating. Drilling an additional cable hole, replacing a sealed gland with an unsuitable fitting, removing a gasket, leaving a connector open or incorrectly fitting an HMI can change the protection provided by the completed enclosure.
Maintenance matters as well. Gaskets can age, plastic components can crack, cable glands can loosen and enclosure doors can become distorted. An IP marking on the original product does not mean that a damaged or incorrectly reassembled enclosure still provides the original degree of protection.
IP ratings and NEMA enclosure types are not identical
IEC IP codes and NEMA enclosure types use different classification systems and should not be treated as exact one-to-one equivalents. Depending on the NEMA type, requirements can include environmental conditions that are not represented in the same way by the two IP numerals.
Conversion charts can be useful as a general engineering reference, but an enclosure marked IP66 should not automatically be declared NEMA Type 4X, and a NEMA marking should not be replaced by an assumed IP code. When a project specification requires one system, check the manufacturer's declared compliance with that specific system.
What should you check before selecting an IP-rated product?
Start with the actual environment rather than simply choosing the highest number. Determine whether the equipment will face ordinary indoor dust, conductive contamination, splashing, rain, wash-down jets, temporary flooding, permanent immersion or hot high-pressure cleaning.
Then check the complete product code, referenced standard, mounting position, connector condition, required accessories and any limits stated by the manufacturer. For immersion applications, verify the permitted depth and duration. For wash-down applications, verify the applicable pressure, temperature, distance and cleaning conditions.
Finally, remember that an IP marking describes a tested enclosure protection level; it does not by itself prove that the entire machine, control panel or installation complies with every applicable safety standard. Product selection should consider the IP rating together with electrical, mechanical and environmental requirements.
IP protection rating guide
Basic enclosure ratings: IP00 | IP20 | IP21 | IP30 | IP40 | IP50
Dust and water protection: IP54 | IP55 | IP65 and IP66 | IP66 | IP67 | IP68 | IP69 | IP69K and ISO 20653
Related standards: Industrial Standards | IEC Standards | IEC 60529 | IEC 61439 | NEMA Standards
Related automation equipment: Panel Components | HMI Panels | PLCs and Modules | AC Drives and VFDs | Pressure Sensors | Sensor Cables and Connectors