General Electric AF-6 Fault index

Hi everyone,

- Error Code 1: 10 Volts Low - Control card voltage is below 10 V from terminal 50. More info (continue >)

- Error Code 2: Live Zero Error - Appears if Live Zero Timeout Function is programmed. More info (continue >)

- Error Code 4: Mains Phase Loss - A phase is missing on the supply side, or the mains voltage imbalance is too high. More info (continue >)

- Error Code 5: DC Link Voltage High - Intermediate circuit voltage (DC) is above the high voltage warning limit. More info (continue >)

- Error Code 6: DC Link Voltage Low - Intermediate circuit voltage (DC) is below the low voltage warning limit. More info (continue >)

- Error Code 7: DC Over Voltage - If intermediate circuit voltage exceeds the limit, the drive stops after a time. More info (continue >)

- Error Code 8: DC Under Voltage - If intermediate circuit voltage (DC link) falls below the under voltage limit, the drive stops. More info (continue >)

- Error Code 9: Inverter Overloaded - Drive may cut out due to overload. More info (continue >)

- Error Code 10: Motor Overload Temperature - Electronic thermal protection indicates the motor is too hot. More info (continue >)

- Error Code 11: Motor Thermistor Over Temperature - Motor thermistor has reached excessive temperature levels. More info (continue >)

- Error Code 12: Torque Limit - The set torque limit has been exceeded. More info (continue >)

- Error Code 13: Over Current - Inverter's peak current limit (approximately 200% of rated current) has been exceeded. More info (continue >)

- Error Code 14: Earth Fault - There is a ground leakage in one of the output phases. More info (continue >)

- Error Code 15: Hardware Mismatch - An installed option card is not compatible with the current control card hardware or software. More info (continue >)

- Error Code 16: Short Circuit - There is short-circuiting in the motor or motor wiring. More info (continue >)

- Error Code 17: Control Word Timeout - No communication to the drive. More info (continue >)

- Error Code 18: Start Failed - Motor speed did not exceed the allowed start maximum speed during startup. More info (continue >)

- Error Code 23: Internal Fan Fault - Checks if the fan is operational. More info (continue >)

- Error Code 24: External Fan Fault - Checks if the fan is operational. More info (continue >)

- Error Code 29: Heatsink Temp High - Maximum heatsink temperature has been exceeded. More info (continue >)

- Error Code 30: Motor Phase U Missing - Motor phase U is missing between the drive and the motor. More info (continue >)

- Error Code 31: Motor Phase V Missing - Motor phase V is missing between the drive and the motor. More info (continue >)

- Error Code 32: Motor Phase W Missing - Motor phase W is missing between the drive and the motor. More info (continue >)

- Error Code 33: Inrush Fault - Too many power-ups within a short time period. More info (continue >)

- Error Code 34: Communication Fault - Problem with the network on the communication option card. More info (continue >)

- Error Code 36: Mains Failure - The supply voltage to the drive has been lost. More info (continue >)

- Error Code 38: Internal Fault - An internal fault has occurred. More info (continue >)

- Error Code 39: Heatsink Sensor - No feedback from the heatsink temperature sensor. More info (continue >)

- Error Code 45: Earth Fault 2 - Ground fault occurred on startup. More info (continue >)

- Error Code 46: Power Card Supply - The supply on the power card is out of range. More info (continue >)

- Error Code 47: 24V Supply Low - 24 V DC is measured on the control card. More info (continue >)

- Error Code 48: 1.8V Supply Low - 1.8V DC supply on the control card is outside of allowable limits. More info (continue >)

- Error Code 49: Speed Limit - Speed is outside the specified range. More info (continue >)

- Error Code 50: Auto Tune Calibration Failed - Auto tune calibration was unsuccessful. More info (continue >)

- Error Code 51: Auto Tune Check Unom and Inom - Settings for motor voltage, current, and power are incorrect. More info (continue >)

- Error Code 52: Auto Tune Low Inom - Motor current is too low. More info (continue >)

- Error Code 53: Auto Tune Motor Too Big - The motor is too large for the auto tune process. More info (continue >)

- Error Code 54: Auto Tune Motor Too Small - The motor is too small for the auto tune process. More info (continue >)

- Error Code 55: Auto Tune Parameter Out of Range - Parameter values of the motor are outside the acceptable range. More info (continue >)

- Error Code 56: Auto Tune Interrupted by User - Auto tune has been interrupted by the user. More info (continue >)

- Error Code 57: Auto Tune Timeout - Auto tune has timed out. More info (continue >)

- Error Code 58: Auto Tune Internal Fault - An internal fault has occurred during auto tune. More info (continue >)

- Error Code 59: Current Limit - The current is higher than the value set in the current limit parameter. More info (continue >)

- Error Code 60: External Interlock - A fault condition external to the drive has commanded the drive to stop. More info (continue >)

- Error Code 62: Output Frequency at Maximum Limit - The output frequency has reached the maximum limit set. More info (continue >)

- Error Code 65: Control Card Over Temperature - The cutout temperature of the control card is reached. More info (continue >)

- Error Code 66: Heatsink Temperature Low - The drive is too cold to operate. More info (continue >)

- Error Code 67: Option Module Configuration Changed - One or more options have been added or removed since the last power down. More info (continue >)

- Error Code 69: Power Card Temperature - Temperature sensor on the power card is either too hot or too cold. More info (continue >)

- Error Code 70: Illegal Drive Configuration - The control card and power card are incompatible. More info (continue >)

- Error Code 80: Unit Restored to Factory Settings - Parameter settings are restored to factory settings after a manual reset. More info (continue >)

- Error Code 92: No Flow - No flow condition detected in the system. More info (continue >)

- Error Code 93: Dry Pump - No flow condition in the system with the drive operating at high speed may indicate a dry pump. More info (continue >)

- Error Code 94: End of Curve - Feedback is lower than the set point, which may indicate leakage in the system. More info (continue >)

- Error Code 95: Broken Belt - Torque is below the no-load torque level set, indicating a broken belt. More info (continue >)

- Error Code 96: Start Delayed - Motor start has been delayed due to short-cycle protection. More info (continue >)

- Error Code 97: Stop Delayed - Stopping the motor has been delayed due to short-cycle protection. More info (continue >)

- Error Code 98: Clock Fault - Time is not set or the RTC clock has failed. More info (continue >)

- Error Code 200: Fire Mode - Indicates the drive is operating in fire mode. More info (continue >)

- Error Code 201: Fire Mode was Active - Indicates the drive had entered fire mode. More info (continue >)

- Error Code 202: Fire Mode Limits Exceeded - Operating in fire mode, one or more alarm conditions have been ignored which would normally stop the unit. More info (continue >)

- Error Code 203: Missing Motor - An under-load condition was detected with a drive operating multi-motors. More info (continue >)

- Error Code 204: Locked Rotor - An overload condition was detected with a drive operating multi-motors. More info (continue >)

- Error Code 250: New Spare Part - A component in the drive has been replaced. More info (continue >)

- Error Code 251: New Type Code - The power card or other components have been replaced and the type code changed. More info (continue >) 

+ Ge VFD User Manuals >>

+ Ge AF-6 (600,650..) Fault index >>

+ Ge AF-6 (600,650..) Fault Codes 1 >>

+ Ge AF-6 (600,650..) Fault Codes 2 >>

+ Ge AF-6 (600,650..) Fault Codes 3 >>

+ Ge AF-6 (600,650..) Fault Codes 4 >>


+ General Electric 2. Main page >

+ VFD Homepage


-

"* The user manuals, commissioning suggestions, error codes, and solution recommendations provided on this page are not binding. The information and documents above are open to and even in need of improvement. As the Otomasyon Mall Community, we gladly welcome your suggestions and contributions. If you have field experience and insights on ease of use, please do not hesitate to share them with us."  22.01.2013      

Your shopping cart is empty!