6ES7 194-4AN00-0AA0

Siemens 6ES7194-4AN00-0AA0 ET 200pro PN/DP Connection Module

6ES7194-4AN00-0AA0 is the CM IM PN DP M12, 7/8" connection module for the ET 200pro IM 154-8 PN/DP CPU. Within the Siemens industrial automation range, this component provides the CPU's field connections through four M12 and two 7/8" connectors. These connections carry PROFINET, PROFIBUS DP and the station power supplies.

When selecting this component from the ET 200pro branch of the Siemens ET 200 distributed I/O family, check the complete CPU order number and the installed connection arrangement together. In machine and process automation applications, an identical connector count does not establish interchangeability between connection modules.

What does each connector do?

X01 DP1 and DP2 serve PROFIBUS DP; X02 P1 and P2 serve PROFINET. X03 is the incoming power connection and X04 passes power onwards. Before maintenance on PLC-based control systems, label cables with these port identifiers to simplify reconnection, particularly where several cables have the same colour.

Five checks before selection or replacement

1. CPU model and product version: Record the IM 154-8 PN/DP CPU and its connection module as separate components. For the IM 154-8F CPU (6ES7154-8FB01-0AB0) and IM 154-8FX CPU (6ES7154-8FX00-0AB0), Siemens requires this connection module at product version 03 or later. When reviewing ET 200 system architecture and module compatibility, compare the product version on the label as well as the order number.

2. M12 connector coding: The PROFIBUS connections use B-coded M12 connectors; PROFINET uses D-coded M12 connectors. When preparing cables for SIMATIC S7 communication systems, verify the coding and pin assignments. Do not force a connector that will not engage; its mating type, orientation or coding may be incorrect.

3. Power circuits and removal: 1L+ supplies the electronics/sensors, while 2L+ supplies the loads. Switch off both supplies before removing a 7/8" connector. Disconnecting a power feed-through can also interrupt downstream stations. When planning maintenance on Siemens PLC and I/O products, record which stations share the same power feed.

4. Installation space and sealing: Module dimensions are 90 × 130 × 51 mm in width, height and depth order. Allow additional space for cable exits and bending. To achieve IP65/IP66/IP67 protection, close unused sockets with suitable caps. Inspect sealing surfaces, threads and connector housings; missing caps or damaged seals require attention before the installation is considered complete.

5. Fault isolation and recommissioning: For a communication interruption, inspect the affected network cable, connector and connection direction first, and distinguish power faults from network faults. Review HMI operator panel alarm records alongside CPU diagnostics. After replacement, check both the local station and devices receiving power or network connections through it.

PDF manuals and connection information

Visit the Siemens ET 200 PDF manuals page for related documentation. In IM 154-8 PN/DP CPU, 06/2010, A5E00860134-02, Section 6.2, pages 137–140, covers connector functions, pin assignments and removal conditions. For F/FX CPUs, also check the version requirement in the corresponding product information. Share CPU and connection module label photographs through Siemens product technical enquiries.

Editor's note: The four M12 sockets are divided between two PROFIBUS connections and two PROFINET connections. Record the CPU order number, the 4AN00 connection module's product version and the port used by each cable together. This makes replacement preparation more precise and helps prevent connection errors.