6ES7 194-4AA00-0AA0
Siemens main menu › SIMATIC S7 › SIMATIC ET 200
Siemens 6ES7 194-4AA00-0AA0 — ET 200pro CM IM DP ECOFAST Cu
Siemens 6ES7 194-4AA00-0AA0 is a CM IM DP ECOFAST Cu connection module for ET 200pro IM 154-1/2 DP interfaces within the Siemens ET 200 distributed I/O family. Its two ECOFAST connections carry PROFIBUS DP and 24 V power through hybrid cabling. The PROFIBUS address switches and switchable bus termination are located on this connection module.
Order number: 6ES7194-4AA00-0AA0
Series / designation: ET 200pro / CM IM DP ECOFAST Cu
Communication: PROFIBUS DP, copper RS-485
Connections: 2 × ECOFAST
Address setting: 1–125 using DIP switches
Supply circuits: 1L+ and 2L+, 24 V DC
Dimensions (W × H × D): 60 × 130 × 60 mm
Role of the ECOFAST connection
Within the ET 200 system architecture, this CM provides the interface's field connections; it is not the IM interface itself. When selecting ET 200 connection components, check the complete fitted IM order number as well. X01 receives PROFIBUS and the supply circuits; X02 forwards them to the next station. Two connections do not provide two independent networks or redundant power.
Similar order numbers require different wiring
4AA00 is the ECOFAST Cu version. 4AC00 uses direct cable connections, while 4AD00 uses M12 and 7/8-inch connections. When comparing ET 200 communication options, preserve the DP versus PN distinction: this product is for PROFIBUS DP and must not be selected as a PROFINET connection module. Fitting a similar-looking CM without adapting the wiring does not establish a valid conversion.
Five selection and commissioning checks
1. Interface and cable: Verify the IM label, ECOFAST connector type and hybrid cable assignment together. Check required plugs, caps and cables among the ET 200 additional modules and accessories; do not assume they are included with the CM.
2. PROFIBUS address: The DIP-switch address must match the station address in the Siemens S7 hardware project and be unique within the segment. Record the old switch positions before replacement so that a used spare is not commissioned with its previous address.
3. Bus termination: Both ends of a PROFIBUS segment require termination. Enabling termination at an intermediate station disconnects subsequent DP stations. Do not change this switch arbitrarily where the bus continues; compare incoming and outgoing cables with the network plan.
4. Power budget: The specified CM feed current is 10 A for each of 1L+ and 2L+. However, Siemens limits the ET 200pro internal busbars to 5 A on 1L+ and 10 A on 2L+. When planning ET 200 power supply components and ET 200 power distribution, distinguish these limits and calculate the total forwarded load together with cable capacity.
5. Physical condition: Inspect connector locks, contacts, seals and the address-switch cover. Fit the appropriate cap to any unused connection. Do not treat this field connection as the same mounting arrangement as cabinet-installed ET 200 terminal modules.
When several modules become unavailable together
If the station's ET 200 digital input modules and ET 200 output modules become unavailable simultaneously, also investigate the interface connection and shared supply path. This symptom alone does not prove a faulty CM. Checking the address, termination switch, ECOFAST connections and 1L+/2L+ supplies first helps narrow down the fault.
Editor's note
Before replacement, photograph the PROFIBUS address, termination setting and cable directions as well as the label. A working CM with the correct order number can still disable the station or downstream segment if its switches are set incorrectly. Transferring the existing settings correctly matters as much as selecting the spare part. Explore other product groups through the Siemens main menu.
Manuals and PDF documentation
Use the ET 200pro system manual on our Siemens ET 200 PDF and user manuals page. Review the CM IM DP ECOFAST Cu, PROFIBUS addressing and termination, wiring diagrams and supply limits sections together. Do not copy pin assignments from a different ECOFAST or PROFINET product.
Related topics and Siemens navigation
Product family: Siemens main menu | SIMATIC S7 | ET 200 family
Station and field devices: Terminal modules | Connection components | PROFIBUS and PROFINET
Technical resources: About ET 200 | Power supply modules | ET 200 PDF manuals