6ES7 153-1AA83-0XB0
Siemens 6ES7 153-1AA83-0XB0 – ET 200M IM 153-1 Interface Module
The 6ES7 153-1AA83-0XB0 is an IM 153-1 PROFIBUS DP interface module for ET 200M stations in the Siemens ET 200 family. It exchanges data between remote S7-300 I/O modules and the main PLC. The IM 153-1 is an interface, not a CPU: the machine program runs in the main controller.
Extended environmental conditions
Siemens identifies the 1AA83 as a version intended for extended environmental conditions. It can therefore be considered where conditions exceed those of a standard installation. The interface rating does not automatically extend to the station's power supply and other modules.
Assess the mounting orientation, cabinet temperature, humidity and mechanical conditions against the limits of every device in the station. The 1AA03 is a standard version; check the complete order number and required environment when selecting a replacement.
Station layout and module capacity
An ET 200M station with an IM 153-1 can accommodate up to 8 compatible S7-300 modules. The maximum address space listed for the IM 153-1 family is 128 input bytes and 128 output bytes. These figures describe I/O data capacity, not the number of physical channels.
A station can combine digital inputs, digital outputs and analog modules to suit the application. For function and special-purpose modules, check support by the IM 153-1; a mechanical fit alone does not establish compatibility.
Power supply and PROFIBUS connection
The nominal supply is 24 V DC, with a permitted range of 20.4–28.8 V DC. Siemens lists a maximum current consumption of 350 mA and typical power loss of 3 W for the IM 153-1. When sizing the station supply, also account for the connected modules and their field loads.
PROFIBUS DP uses RS-485 through a 9-pin D-sub connector. The baud rate is detected automatically, up to 12 Mbit/s. Switches on the module set the PROFIBUS address from 1 to 125. This model has no direct PROFINET or Ethernet interface.
Configuration and product revision
The ET 200M station can be configured in STEP 7 hardware configuration or an engineering tool using the appropriate GSD file. The PROFIBUS address, module sequence and parameters in the project must match the installed station. The Siemens manual lists SIEM801D.GSD for the IM 153-1 and SI01801D.GSG for DPV1.
DPV1 mode is supported from module revision E03 of the 1AA83. Two units with the same order number may therefore have different capabilities. Check the E revision on the label and the GSD version required by the project, particularly when DPV1 is in use.
IM 153-1, IM 153-2 and module replacement
The IM 153-1 provides basic remote I/O communication. It does not support interface redundancy, time stamping of input signals or CiR system modification in RUN. Where these functions are required, a suitable IM 153-2 version and station configuration must be assessed. The available ET 200 communication interfaces do not all have the same capabilities.
According to Siemens' revision comparison, the 1AA83 does not support replacement of I/O modules during operation. Before replacement, disconnect the interface and relevant load supplies in accordance with the manufacturer's instructions and site procedures. Select connection modules and ET 200 accessories to suit the existing station layout.
Fault checks
ON indicates the supply status, BF a PROFIBUS bus fault and SF a group fault. If BF or SF is active, record whether the LEDs are steady or flashing and read the diagnostic information from the PLC before deciding to replace the interface.
Check the supply voltage, PROFIBUS connector and cable, bus termination, station address and configured module sequence. The cause may also lie in the main S7-300 CPU, field wiring or another module in the station. An alarm on an operator panel or SCADA system should be assessed alongside the PLC and station diagnostics.
Editor's Note: When choosing a spare, the words “IM 153-1” alone are not enough. Check the 1AA83 order code and E revision on the label. In a project using DPV1, do not assume that a unit earlier than E03 has the same functionality. Also account for the fact that this version does not support I/O module replacement during operation.
Manuals and related topics
For installation, wiring, diagnostics and revision differences, visit the Siemens ET 200 manuals and PDF documents page. For an overview of the family, see about Siemens ET 200.
Navigation: Siemens automation · SIMATIC S7 · Siemens ET 200 · OtomasyonAVM home