6ES7 138-4FC00-0AB0

Siemens 6ES7 138-4FC00-0AB0 – ET 200S PROFIsafe 4 F-DI / 3 F-DO Safety Module

Siemens 6ES7 138-4FC00-0AB0 combines safety-related inputs and outputs in one electronic module for SIMATIC ET 200S stations. Its designation is 4 F-DI / 3 F-DO DC24V/2A PROFIsafe. It provides a compact interface between field devices and the safety program where input monitoring and output control are required at the same location.

Role in the safety system

The module connects safety-related field signals to the control system. Depending on the validated machine design, these may include protective guards, emergency-stop circuits and other safety functions. Selecting an ET200 safety module also involves checking the F-CPU, connected devices and application requirements.

A signal appearing in a PLC program does not by itself establish a validated safety function. The hardware arrangement, safety logic, wiring and acceptance tests must support the intended protective action.

Understanding the four fail-safe inputs

4 F-DI refers to four safety input functions evaluated through two-channel connections. The module supports 1oo2 evaluation only, with two channels evaluated together for each safety signal. Channel planning therefore differs from the independent-channel arrangement commonly associated with standard digital input modules.

The achievable classification is SIL 2 / Category 3 / PL d. The safety performance of the complete machine function depends on the entire chain, including the sensors, wiring, logic and final switching devices.

Fail-safe outputs and load selection

The output section provides three P/M-switching outputs rated at 2 A per channel. Both sides of the load circuit form part of the switching arrangement. Wiring practices used with standard digital output modules should not be transferred without checking the applicable circuit diagram.

When selecting a contactor, distinguish its coil requirements from the motor current carried by its main contacts. The guide to relays and contactors explains this distinction. Coil current, switching frequency, protective components and feedback monitoring all affect the final design. Total loading must also respect the limits associated with mounting orientation and ambient temperature.

Key technical data

Rated supply: 24 V DC. Permitted supply range: 20.4–28.8 V DC. Electronic module dimensions: 30 × 81 × 52 mm. Approximate weight: 73 g. Address allocation: 7 input bytes and 5 output bytes. Specified maximum field cable length: 30 m, subject to the applicable wiring and EMC requirements.

Review the station’s power supply modules and potential distribution when checking the installation. Electronic module dimensions do not represent the complete assembly with its terminal base and wiring clearance.

Terminal modules and installation

Supported terminal options include TM-E30S44-01, TM-E30C44-01, TM-E30S46-A1 and TM-E30C46-A1. S versions use screw terminals; C versions use spring terminals. Their respective order numbers are 6ES7193-4CG20-0AA0, 6ES7193-4CG30-0AA0, 6ES7193-4CF40-0AA0 and 6ES7193-4CF50-0AA0.

When choosing an ET200 terminal block, consider access to AUX1 as well as the connection method. The 44-01 and 46-A1 bases have different auxiliary terminal arrangements. Terminal assignments must follow the electronic module’s wiring documentation.

PROFIsafe and station compatibility

PROFIsafe communication uses the appropriate ET 200S station interface. Siemens lists IM151-1 High Feature, IM151-3 PN HF, IM151-3 PN FO and specified F-CPU options for this module. Exact order numbers and firmware requirements matter; compatibility should not be assumed for every IM151 variant.

For either a PROFIBUS or PROFINET installation, check the station connection components, F-CPU and engineering software together. In an existing S7-300 project, the precise CPU model and its safety capabilities remain essential.

Legacy STEP 7 Safety Advanced V11 projects

Siemens product warning A5E31857732-AA, dated February 2013, covers this module when used with STEP 7 Safety Advanced V11. Certain combinations of discrepancy behavior and reintegration after discrepancy error can be assigned incorrectly during compilation. Actual behavior may therefore differ from the configured settings and printed safety data. Affected projects must be assessed using the scope and corrective instructions in that warning.

If the historical workaround was applied, its effects must also be reviewed when upgrading the project to a later Safety version.

Diagnostics and replacement planning

For maintenance, keep the project backup, hardware configuration and diagnostic records together. Before restoring a system that has entered its safe state, establish whether the event originated in the supply, field wiring, parameter assignment or communication. Front-panel LEDs alone do not prove that the safety function operates correctly.

6ES7138-4FC00-0AB0 and 6ES7138-4FC01-0AB0 are distinct order numbers. A replacement decision should compare the installed device label, accepted project configuration and manufacturer’s substitution requirements, rather than relying only on the shared “4 F-DI / 3 F-DO” description.

Manuals and related topics

Visit the Siemens ET200 manuals and PDF page for documentation resources. Check the order numbers covered by each document: later editions describing FC01 should not automatically be treated as complete instructions for FC00.

Related topics: understanding Siemens ET200 and Safe Torque Off (STO). A drive’s STO interface requires its own compatibility assessment; the presence of this module does not establish suitability for a direct connection.

Editor’s note: For replacement enquiries, record the complete module order number, terminal base and Safety software version together. On older machines, matching the installed hardware to the last accepted project is a useful starting point before choosing a spare.