6ES7 138-4AA00-0AA0 is a 15 mm ET 200S RESERVE module in the Siemens SIMATIC product family. It reserves a position for a future electronic module in ET 200 distributed I/O stations. Use it as part of a documented expansion plan that makes the intended station layout clear to commissioning and maintenance teams.

Five points for selection and application

1. Define the reserved position: When selecting ET 200 additional modules, first record the future purpose of each slot. A position planned for ET 200 digital input modules can be documented with its sensor group, terminal references and project description. A label such as “future conveyor sensors” gives the next engineer more useful information than an unexplained “spare” label.

2. Terminal module: The RESERVE module fits a TM-E terminal module of the appropriate width and has no electrical connection to its field terminals, allowing wiring to be prepared. Select the ET 200 terminal base for the electronic module that will eventually be installed. When reviewing ET 200 connection components, keep terminal assignments, cable labels and project signal names together in the station documentation.

3. Hardware configuration: Without option handling, configure the future electronic module and enable “Operation at Preset <> Actual configuration” on the interface. SF and an incorrect-module diagnosis can then occur. Compare the Siemens S7 hardware project with the physical module sequence. If using supported option handling, follow the interface manual’s requirements separately; include configuration checks in the commissioning plan.

4. Interface compatibility: RESERVE cannot be used with IM151, 6ES7151-1AA00-0AB0. Some older interfaces require a supply power cycle after replacing an electronic module with RESERVE; check the exact order numbers on manual page 14-1. Record the full ET 200 communication interface identification and revision in the maintenance file. Coordinate the commissioning procedure with the machine’s shutdown requirements.

5. Plan the future load: Assess ET 200 power supply capacity using the future module and its field devices. For positions intended for ET 200 digital output modules, document the proposed load current, protection and potential group. A maintained list of reserved positions helps the next expansion start with clear design information.

Editor’s note

A useful reservation record brings together three details: the slot number, the full order number of the intended module, and the purpose of its field connections. Keep that record with the panel documentation. When investigating a diagnostic message, compare the installed hardware with the project’s expected configuration before deciding on a replacement.

PDF and technical documentation

Visit the Siemens ET 200 PDF and user manual library for the documentation guide. The primary reference for this order number is chapter 14 of the ET 200S system manual, edition 12/2004, EWA-4NEB 780602402-12. The included 04/2007 RESERVE manual covers 4AA01/4AA11; check the order numbers on the cover when choosing a document.

Related topics

Terminal bases • Connection modules • Digital inputs • Digital outputs • Power distribution • Additional modules

Otomasyon AVM • Siemens guide

Siemens main menu  |  SIMATIC S7 family  |  ET 200 module categories  |  ET 200 PDF archive