6ES5 980-0MB11

Siemens 6ES5 980-0MB11 S5 Lithium Memory Backup Battery

Siemens 6ES5 980-0MB11 is a lithium memory backup battery for SIMATIC S5 systems. The accessory table in the S5-90U 6ES5 090-8MA01 guide specifies ½ AA, 3.4 V / 850 mAh. These are the product values stated in that historical Siemens document.

The battery supports retention of program memory and relevant retentive data when the main supply is absent. It does not replace the S5 CPU’s operating supply. Select this S5 accessory against the complete battery code, connection arrangement and installed CPU.

Documented system applications

The Siemens S5-100U manual also lists 980-0MB11 among CPU accessories. Its list includes CPU 100 / 100-8MA02, CPU 102 / 102-8MA02 and CPU 103 / 103-8MA03. Check the equipment documentation before applying the part to a different CPU or battery revision.

Voltage, polarity and connection

Voltage or physical size alone is insufficient for selecting a substitute. Compare cell type, capacity, polarity and connection equipment. For cables and connectors, use the battery and CPU markings rather than wire colour alone. This lithium battery must not be recharged.

Preserving the program during replacement

Obtain a current PLC program backup and confirm that it can be restored before starting. Prepare the installed service equipment, such as a PG 605U, and its programming interface. Check that the backup is readable and belongs to the actual CPU.

The S5-90U/95U manual requires battery replacement with the PLC powered; otherwise it specifies an overall reset after power-on. Plan the work with CPU power maintained and unexpected machine movement prevented under safe maintenance conditions. Establish the data-retention plan before combining replacement with supply interruption or other work on the rack.

No low-battery LED on the S5-90U

The S5-90U has no low-battery warning LED. Siemens recommends annual preventive replacement for this model. Record the date and avoid treating normal powered operation as evidence of battery condition. During recommissioning, compare digital input and digital output responses with the recorded operating state.

Stored stock and service records

For unused older stock, inspect the production date, storage history and packaging. Before attributing a problem after replacement to combined I/O, a communications module or a function module, establish whether the program and required data were retained.

For an older Siemens S5 system, record the installation date, battery code, CPU and service result. Open-circuit voltage alone does not establish remaining capacity. Do not verify retention by interrupting power without a current backup and a prepared recovery procedure.

Editor’s note

Check the program backup before touching the battery. A working machine does not establish that a usable backup exists. Replacing the cell is quick; recovering an undocumented older program can take much longer.

Inspect the date even when the packaging is unopened. A cell stored for years should not be assessed as recent production merely because it is unused. State known production and storage information in the offer.

On an S5-90U, the absence of a battery warning is not reassurance: this model has no such indicator. Put the replacement date on the maintenance record so that the next check does not depend on memory.

A connector that fits does not establish a suitable cell. Confirm polarity and battery type before installation. Do not attempt to restore this battery by charging it; it is not a rechargeable accumulator.

Finish by checking the program, required settings and expected machine response, rather than the RUN indicator alone. Keep a removed, used battery separate from serviceable replacement stock.

OtomasyonAVM resources and PDFs

+ 6ES5 980-0MB11 product and information page and S5-90U 090-8MA01 homepage.

+ OtomasyonAVM S5-90U PDF files: S5-90U operating and memory-retention documentation.

+ OtomasyonAVM shared SIMATIC S5 PDF archive: access to S5-100U and other S5 system documents.

Related topics

+ S5 memory modules, PLC programming, PG 605U service equipment and S5 connection accessories.

Browse SIMATIC S5

S5-90U  |  Siemens S5 models  |  S5 supporting equipment  |  Siemens second-hand homepage

Siemens and external references

+ Siemens S5-90U Anleitung, German. EWA 4NEB 812 6064-01a; F-1 lists the exact 980-0MB11 code and ½ AA, 3.4 V / 850 mAh specification.

+ Siemens S5-90U/S5-95U System Manual, English. EWA 4NEB 812 6115-02b; Section 4.4.2 covers retention, replacement conditions and the S5-90U monitoring limitation.

+ Siemens S5-100U System Manual, English. EWA 4NEB 812 6120-02b; D-2 lists the exact 980-0MB11 code among CPU accessories.