6ES5 927-5BA12

Siemens 6ES5 927-5BA12 — S5-150A 927-5 central processing board

Siemens 6ES5 927-5BA12 is a 927-5 central processing board for the SIMATIC S5-150A central controller. Siemens’ maintenance documentation identifies it as “Zentralbaugruppe 3” — central board 3. This CPU board in the Siemens S5 family forms part of the S5-150A’s multi-board central processing arrangement.

Siemens ST 53 lists 6ES5 925-5AA12, 6ES5 926-5AA12 and 6ES5 927-5BA12 together for ZG 150A. The 927-5BA12 should therefore not be treated as a compact CPU containing all PLC functions on its own. Select a replacement in the context of the installed board group.

Operating-system EPROM and user memory

S5-150A program memory is arranged through separate RAM/EPROM memory boards. The ST 53 layout shows 340-5 and 350-5 memory boards separately from the central processing group. The 927 part number alone does not establish RAM capacity or the installed memory submodules.

The jumper table covering 927-5BA12 includes MEM settings enabling the operating-system EPROM. Keep the operating system distinct from the user program. The presence of EPROMs on a used board does not establish the correct system version or a ready-to-run machine program.

NAU, BAU and jumper settings

Siemens’ System 8 maintenance table explicitly covers 927-5BA12. It identifies Br.1 for NAU/BAU signal selection, Br.2 for GEP enable, Br.3 and Br.4 for operating-system EPROM enable and Br.5 for the ZYK test point.

These jumpers should not be treated as ordinary address switches. Photograph the installed arrangement and, if changes are required, follow the table applicable to the board revision and system documentation. Copying another 927 board’s settings does not establish suitability for the installation.

Programmer connection and STEP 5

The S5-150A arrangement uses a separate 511-5 programmer connection board. Select the 511-5 family PG interface, suitable connection hardware and programming cable together. Do not assume that 927-5BA12 provides a modern communications port for direct connection.

ST 53 also shows a 984-1U adapter for the older PG 605U connection arrangement; the 6ES5 984-1UA11 adapter page relates to this connection group. For STEP 5 programming, check the programmer model, connection board and adapter arrangement together.

Rack arrangement and internal 5 V supply

The board operates within ZG 150A’s own mechanical and electrical arrangement. Assess the rack layout, central-board order and expansion connections together. The S5-150A power supply provides the system’s internal 5 V supply; its mains or 24 V DC input is not a voltage to apply directly to the 927 board.

The digital input and digital output arrangement is built through the appropriate S5-150A peripheral and expansion boards. Total system I/O or program capacity must not be presented as physical channels or internal RAM built into a single 927-5BA12 board.

Diagnostics and differences between 927 codes

During fault-finding, examine the complete central-board group, supply and backup condition, EPROM labels, jumpers and connectors together. For S5 maintenance, record the installed arrangement before attributing a startup fault solely to the 927 board.

6ES5 927-5BA13 is another order version. 6ES5 927-3KA13 belongs to S5-150K, while 6ES5 927-3SA11 belongs to a different arrangement in the S5-150S family. Do not treat 5BA, 3KA and 3SA codes as direct substitutes merely because they share the number 927.

Editor’s note

When buying used Siemens equipment, inspect the 5BA12 label, EPROM markings and both sides of the board. A listing saying only “CPU 927” is insufficient for selecting the correct spare.

Before removal, record the order and complete part numbers of the 925, 926 and 927 boards. Preserve the installed group’s revision information when replacing one board.

Photograph the jumpers and do not change Br.1–Br.5 simply to match another board. Avoid trial changes to operating-system EPROM enable settings.

For startup faults, check the internal 5 V supply, backup arrangement and connectors using the appropriate procedure. Bent contacts or oxidation can lead to an unnecessary board replacement.

Test with the correct S5-150A board group, suitable PG connection and available program backup. Record the accompanying boards and EPROM versions alongside the test result.

OtomasyonAVM resources and PDFs

Browse the 6ES5 927-5BA12 model page, SIMATIC S5 CPU family and used Siemens equipment. General documents are collected in the shared Siemens S5 PDF archive. The Siemens documents used for this model are linked below and are in German.

Related topics

+ 6ES5 925-5AA12 — first board in the ZG 150A central processing group.

+ 6ES5 926-5AA12 — second board in the ZG 150A central processing group.

+ 6ES5 927-5BA13 — another 927-5 order version.

+ 6ES5 927-3KA13 — a different 927 board for S5-150K.

+ 6ES5 927-3SA11 — a different 927 board for S5-150S.

Browse SIMATIC S5

S5 CPUs · S5 racks · S5 memory modules · S5 interfaces · Siemens S5 PLC · Used Siemens equipment

Siemens and external references

Siemens ST 53 — SIMATIC S5-130 / S5-150, 1985 — German. PDF p. 12: system structure. PDF p. 16 / printed 2/2: ZG 150A central and memory boards. PDF p. 25 / printed 2/11: programmer connection arrangement. PDF p. 127 / printed 9/9: exact 927-5BA12 order number and associated 925/926 boards.

Siemens System 8 — Inbetriebnahmeanleitung, PC-Teil, I/2 — German compilation. PDF p. 39 / printed 5-14, A 10.82: jumper table for 925-5AA12, 926-5AA12 and 927-5AA12/5BA12/5BA13. Br.1–Br.5 functions explicitly cover 5BA12.