6ES5 740-0AA11
Siemens 6ES5 740-0AA11 Module Enclosure Without Terminal Strip
Siemens 6ES5 740-0AA11 is identified as a type 740 module enclosure/holder without a terminal strip for SIMATIC S5. It belongs among S5 supporting accessories. Selection requires matching the enclosure construction, carrier mounting and physical form of the board to be installed.
Siemens ST 53 describes the S5-130A and S5-150A Robustbauform arrangement and illustrates a 740 metal enclosure mounted on a support profile. The enclosure protects and guides the board within the S5 carrier assembly, with internal guides and provisions for heat dissipation. When selecting SIMATIC S5 hardware, match the mechanical construction as well as the controller family.
What does “without terminal strip” mean?
The 740-0AA11 is described as an enclosure without a terminal strip. Do not transfer the connection arrangement of a different terminal-equipped enclosure, such as the 6ES5 741-0AB31, to this model. Establish the required cables and connectors from the board and the existing installation. Adding an arbitrary terminal block does not demonstrate compatibility.
Where the assembly contains S5 interface modules, such as a 6ES5 301-5CA12 or 6ES5 310-5AA12, inspect the adjacent cable routing during maintenance. These are layout examples; direct enclosure compatibility must be established separately from the applicable mounting documentation.
Mechanical fit and installation
For a digital input, digital output or combined I/O board, the shared S5 designation is only a starting point. Check entry into the guides, fixing points, connector alignment and cover clearance. Do not force a board that does not slide into position correctly.
Analog modules, special modules and function modules may have different physical and connection requirements. Keep the enclosure openings clear of cables, added parts and coatings. A component requiring modification must not be treated as a direct mechanical replacement.
Isolate the power supplies and any separate field supplies before installation. Consider separately whether any work on memory modules or the application program is necessary. The purpose of replacing the enclosure is to maintain the correct seating and mechanical integrity of the existing board.
Inspecting and accepting a used enclosure
On an older S5 installation, inspect dismantled mechanical parts beyond their surface appearance. Look for a twisted housing, damaged guides, stripped fixing points and edges that could scrape the board. Photograph signs of previous cutting, drilling or filing and compare the relevant dimensions.
Before dismantling an arrangement containing components such as the 6ES5 312-5AA13 or 6ES5 512-5BC21, record the positions of boards and cables. During reassembly, check that the enclosure does not trap a cable, pull a board sideways or strain its connections. These examples are not an enclosure compatibility list.
The quotation should identify the complete order number, supplied housing and fittings, actual quantity and physical condition. Confirm the inclusion of covers, screws and other accessories through photographs and a supply list. Dimensions, weight and protection ratings must not be assigned to the 0AA11 version without matching documentation.
Editor’s note
Start by checking that the housing is straight. A slightly twisted enclosure can put sideways pressure on the connector as the board is installed. The screws engaging does not prove that the assembly is seated correctly.
If the board catches at one point, stop and inspect the guides. Look for a burr, a broken guide or a misaligned connection before trying again. A small mechanical defect should not be allowed to damage a sound board.
Keep metal debris and loose screws out of the enclosure during cleaning. Inspect the openings and remove heavy contamination using an appropriate method with the board removed. Thick cosmetic paint can interfere with mating surfaces.
Clarify “without terminal strip” before buying. A connection part shown beside the enclosure in a photograph may not be included. A clear supply list saves the trouble of chasing missing parts later.
Take several photographs before dismantling the old arrangement. Screw lengths, cover orientation and cable routing are small details that help during reassembly. Keep the original enclosure available for comparison until the replacement has been checked.
OtomasyonAVM resources and PDFs
+ 6ES5 740-0AA11 product and information page and Siemens S5 models.
+ 6ES5 741-0AB31 enclosure page, for comparison of the different terminal arrangement.
+ OtomasyonAVM shared SIMATIC S5 PDF archive. This is a general system archive; a manual for another S5 family must not be substituted for the dedicated mounting documentation for the 740-0AA11.
Related topics
+ S5 carriers and racks, S5 cables and connectors and S5 expansion products.
+ About Siemens S5 PLC and S5 interface modules.
Browse SIMATIC S5
S5 expansion products | S5 carriers | SIMATIC S5 | Siemens second-hand homepage
Siemens and external references
+ Siemens SIMATIC S5 ST 53, 1985: S5-130 and S5-150 automation systems, German archive copy. The “Robustbauform” and “Kapseln” sections and Figure 1/7 describe the 740 enclosure arrangement. This is a family construction reference, not a standalone data sheet for order number 6ES5 740-0AA11.