6ES5 444-5AA11
Siemens 6ES5 444-5AA11 – 16-Channel 24 V DC / 2 A Digital Output Module
6ES5 444-5AA11 is a Siemens SIMATIC S5 module with 16 digital outputs, a nominal load voltage of 24 V DC and a rating of 2 A per channel. This member of the S5 digital output range uses Robustbauform / A-type construction and is non-isolated. The permitted load supply range is 20–30 V DC.
System compatibility and common reference
Siemens catalog ST 53 lists this exact order number for S5-130A and S5-150A systems. Match the rack and rear connections in the SIMATIC S5 system to the A-type construction. Separate L+ supply terminals do not establish galvanic isolation between outputs.
Prepare field cables using the existing drawing for load returns, the card’s common reference and grounding. Check these arrangements when replacing a different output type.
Load current and loading at 55 °C
The permitted on-state current is 15 mA–2 A. At 55 °C, loading is limited to 40% of the sum of rated output currents through each L+ supply. Add up the loads separately for each L+ feed when sizing the power supply and wiring. Do not assume that all 16 channels can continuously carry 2 A at the same time.
Short-circuit protection and overload
The catalog specifies electronic short-circuit protection and explicitly states that the card is not overload-proof. With control relays and other coil loads, check pickup current and continuous current together. Test a used output module with a suitable load and current limit.
Switching and output levels
Maximum switching frequencies are 100 Hz for resistive loads, 11 Hz for lamps and 2 Hz for inductive loads at rated loading. The lamp-load limit is 10 W. Internal inductive turn-off voltage limitation is −15 V.
The specified output voltage is at least Up − 2.5 V at signal “1” and no more than +3 V at signal “0”. Maximum off-state residual current is 1.5 mA. When connecting to digital inputs or combined input/output modules, check the receiving circuit’s thresholds and common-terminal requirements.
Cable length and physical construction
Catalog cable limits are 400 m unshielded and 1000 m shielded. Assess conductor size and voltage drop separately, particularly at higher load currents. Approximate module weight is 0.3 kg.
Differences from similar models
The 6ES5 444-3AA11 is a separate model with compact K construction. The 6ES5 441-5AA12 has a different output-current rating. Check the construction and load specifications for each complete order number.
The 6ES5 450-6AA12 and 6ES5 451-5AA13 are separate isolated output models. A comparison with 6ES5 454-5AA11 also requires the exact model’s documentation; a “2 A output” description alone is insufficient for selection.
Cards with different constructions, such as 6ES5 451-3AA11, require their own installation and addressing assessment. Record the existing S5 system’s I/O list, wiring drawings and hardware coding before replacement.
Used-module inspection and replacement preparation
Back up the program and memory unit, then test all 16 channels in sequence with suitable loads. For used Siemens modules, state the label details, included connection parts, physical condition and completed tests for the individual item. Indicators or unloaded voltmeter readings alone do not establish the condition of the card.
Editor’s note
Read the 2 A rating together with the loading limits. Each channel has its own limit, and cabinet temperature affects combined loading. List the loads for each L+ feed and apply the 40% condition at 55 °C.
Give the short-circuit protection a fair working load. Siemens explicitly states that this model is not overload-proof. Checking inrush current first is easier than tracing a damaged output later.
Keep the non-isolated construction in mind. Follow the common reference and return wiring carefully. Compare existing connections with the drawing before transferring them from another card.
Check the difference between 444-3 and 444-5. Similar functions do not establish matching construction or installation. Look at the label, connector and rack together before choosing a replacement.
Finish by checking all 16 channels. Save the program, then test each output with a suitable load. Keep a short record so you know what was checked when the card is needed again.
OtomasyonAVM resources and PDFs
+ Shared SIMATIC S5 manuals and PDF archive
+ S5 digital output modules and model pages
Related topics
+ 6ES5 444-3AA11 compact output module
+ 6ES5 441-5AA12 digital output module
+ 6ES5 451-5AA13 isolated output module
Browse SIMATIC S5
+ Back to S5 digital output modules
+ Used Siemens products and models
Siemens and external references
+ Siemens ST 53, 1985 – 444-5 specifications and loading footnotes, 8/6 (German)
+ Siemens ST 53 – 444-5 wiring and L+ supply arrangement, 8/21 (German)
+ Siemens ST 53 – exact 444-5AA11 code and 130A/150A listing, 9/6 (German)