6ES5 188-3UA21

Siemens 6ES5 188-3UA21 | SIMATIC S5-135U/155U central rack

The 6ES5 188-3UA21 is a 21-slot central rack (CC) for the S5-135U/155U systems in the Siemens SIMATIC S5 family. Its backplane links the processor and plug-in modules and distributes system power. The original Siemens ordering specification excludes the CPU. The installed processor runs the machine’s STEP 5 program.

This S5 rack has card guides, a top retaining bar and a fan-cooled power supply in the lower section. When sourcing a replacement, check the rack and power supply nameplates separately.

Power supply and ordering variants

Edition 03 of the Siemens system manual pairs this rack with the 6ES5 955-3LF41 supply. The product catalog lists 230/115 V AC input. The LF41 documentation describes the selector settings as 120/230 V AC. The 5 V DC rail is rated at 40 A. The manual also lists 15 V DC at 2 A and 24 V DC at 2.8 A.

Several S5 power supplies have similar front panels. Use the full order number to identify the unit. The 40 A rating applies to the 5 V rail when checking the module load. Check the nameplate and voltage selector before power-up.

The AC-fed 6ES5 188-3UA11 is the 18 A version. Siemens lists the AC-fed 40 A 6ES5 188-3UA22 with a 955-3LF42 supply in edition 07. The 6ES5 188-3UA32 is an 18 A version with a 24 V DC input. Match the full rack and PSU numbers as well as the existing module layout.

CPU, slot assignments and expansion

Systems in this family can have a CPU 928A or CPU 928B. The CPU 948 is used in S5-155U configurations. Match the exact processor, its slot width and the S5 memory card to the installed project. A multiprocessor rack also needs the correct coordinator and slot assignment, for example the 923C coordinator.

Use the Siemens slot-assignment chart for digital inputs, digital outputs, analog I/O and communications modules. Record the original slot numbers and order codes, especially for CPU and communications cards, before moving anything.

The EU 183U expansion unit is a separate peripheral rack. IM 300-3 is used for centralized expansion and IM 304 for distributed expansion. Check the existing interface pair, S5 cables and connectors and any terminator as a set.

What to check on a used rack

Ask for photos of both nameplates and inspect the backplane connectors, card guides and top retaining bar. Confirm exactly which parts come with the rack, including the condition of the power supply and fan assembly.

Before commissioning, keep a STEP 5 program backup and a record of the module layout. A bench test can check the 5 V status, fan warning and battery indicators together.

Editor’s Note
If the system drops out when a fan warning appears, have the fan assembly and the 5 V power rail checked under load before replacing the rack.

Manuals and PDF files

Section 4.1 of the Siemens system manual covers the central rack. Section 4.3 covers the power supplies. Visit the SIMATIC S5 PDF archive on OtomasyonAVM.

Related topics

About Siemens S5 PLCs · S5 digital I/O cards · S5 expansion modules

Navigation

S5 CPU and rack directory · SIMATIC S5 range · Used Siemens automation · Used automation equipment

References

Siemens Industry Mall – 6ES5188-3UA21 product record
SIMATIC S5-135U/155U System Manual – Release 03, sections 4.1 and 4.3
Siemens S5-135U/155U System Manual – Edition 07, PDF