Yaskawa 616 G5 parameter list 2

C4-02 Torque compensation time constant (Torque Compensation Time) 20
d4-01 Frequency reference hold function selection (MOP Memory Hold) 0
ASR proportional (P) gain 1 (ASR P Gain 1) ?? .00
d4-02 Speed limits (Trim Control Level) 2.5
ASR integral (I) time 1 (ASR I Time 1) 0.500
d5-01 Torque control selection (Torque Control Select) 0
ASR proportional (P) gain 2 (ASR P Gain 2) 20.00
d5-02 Torque reference delay time (Torque Ref Filter) 0
ASR integral (I) time 2 (ASR I Time 2) 0.500
d5-03 Speed limit selection (Speed Limit Select)
ASR limit (ASR Limit) 100
d5-04 Speed limit (Speed Limit Value) 0
ASR primary delay time (ASR Delay Time) 0.000
d5-05 Speed limit deviation (Speed Limit Deviation) 10
ASR switching frequency (ASR Gain Switching Freq) 0.0
d5-06 Speed/torque control transition timer (Ref Hold Time) 0
ASR integral (I) limit (ASR I Limit)
E1-01 Input voltage setting (Input Voltage) 400
C6-01 Carrier frequency upper limit (Carrier Freq Max) 15.0
Motor selection (Motor Selection) 0
C6-02 Carrier frequency lower limit (Carrier Freq Min) 1.5
V/f pattern selection (V/f Selection) 0
C7-01 Hunting prevention selection (Hunting Prevention Select)
Maximum output frequency (Max Frequency)
C7-02 Hunting prevention gain (Hunting Prevention Gain)
Maximum voltage (Max Voltage)
Base frequency (Base Frequency) 50
Mid output frequency (Mid Frequency A) 30
Mid output frequency voltage (Mid Voltage A) 22
Minimum output frequency (Min Frequency) 0.1
Minimum output frequency voltage (Min Voltage) 4.0
Second mid output frequency (Mid Frequency B) 0.0
Second mid output frequency voltage (Mid Voltage B) 0.0
Base voltage (Base Voltage) 0.0
Motor nominal current (Motor Nominal FLA)
Motor nominal slip (Motor Nominal Slip) 2.5
Motor no-load current (No-Load Current) 0.6
Motor pole number (Pole Number) 4
Motor line-line resistance (Line-Line Resistance) 18.196
Motor leakage inductance (Leakage Inductance) 1.6
Motor iron core saturation coefficient 1 (Saturation Comp 1) 0.1
Motor iron core saturation coefficient 2 (Saturation Comp 2) 0.75
Motor mechanical loss (Mechanical Loss) 0.0
Second motor control method selection (Control Method) 2
Motor 2 maximum voltage (Motor 2 Max Voltage) 400.0
Motor 2 minimum output frequency voltage (Motor 2 Min Voltage) 40
Motor 2 nominal current (Motor 2 Nominal FLA) 1.0
Motor 2 nominal slip (Motor 2 Nominal Slip) 2.90
Motor 2 line-line resistance (Motor 2 Line-Line Resistance) 18.198
Motor 2 leakage inductance (Motor 2 Leakage Inductance) 18.2
PG open circuit operation selection (PG Open Circuit Select)
Deviation operation selection (Deviation Select)
PG rotation direction (PG Rotation Select) 0
PG division ratio (PG Output Ratio)
Integral value active/passive selection during acceleration/deceleration (Acc/Dec IV Select) 0
Over-speed detection level (Over-Speed Level) 11.1
Over-speed detection delay time (Over-Speed Time) 0.0
Over-speed deviation detection level (Over-Speed Deviation Level) 10
Over-speed deviation detection delay time (Over-Speed Deviation Time) 0.5
PG tooth number 1 (PG# Tooth Number 1) 0
PG tooth number 2 (PG# Tooth Number 2) 0
PG open circuit detection time (PG Open Circuit Time) 20
Multi-function input (terminal 3) setting (Terminal 3 Setting) 24
Multi-function input (terminal 4) setting (Terminal 4 Setting) 14
Multi-function input (terminal 6) setting (Terminal 6 Setting)
Multi-function input (terminal 7) setting (Terminal 7 Setting) 64
Multi-function input (terminal 8) setting (Terminal 8 Setting) 86
Multi-function input (terminal 9-10) setting (Terminal 9 Setting) 0
Multi-function input (terminal 25-27) setting (Terminal 25 Setting)
Multi-function input (terminal 26-27) setting (Terminal 26 Setting)
Signal level selection for terminal 13 (Terminal 13 Signal) 0
Gain for terminal 13 (Terminal 13 Gain) 1000
Signal level selection for terminal 16 (Terminal 16 Signal) 0
Monitoring selection for terminal 21 (Terminal 21 Selection) 2
Gain for terminal 23 (Terminal 23 Gain) 0.0
Deviation for terminal 23 (Terminal 23 Deviation) 0.0
Analog output signal level selection (AO Level Selection) 0
Station address (Serial Communication Address) 1F
Communication speed selection (Serial Baud Rate)
Communication parity selection (Serial Communication Select) 0
Stop method after communication error (Serial Error Select)
Communication error detection selection (Serial Error Detection)
Motor protection selection (Motor Protection Select)
Motor protection time constant (Motor Protection Time Constant) 1.0
Instantaneous power loss detection (Instantaneous Power Loss Select) 0
Instantaneous power loss skip time (Instantaneous Power Loss Skip Time) 10
Minimum baseblock time (Minimum Baseblock Time) 0.5
Voltage recovery time (Voltage Recovery Time)
Stall prevention selection during acceleration (Acc Stall Prevention Select)
Stall prevention selection during deceleration (Dec Stall Prevention Select)
Stall prevention selection during operation (Run Stall Prevention Select)
Stall prevention level during operation (Run Stall Prevention Level) 160
Speed agreement detection level (Speed Agreement Detection Level) 0.0
Speed agreement detection width (Speed Agreement Detection Width) 20
Torque detection level 1 (Torque Detection Level 1)
Torque detection selection 2 (Torque Detection Select 2) 0
Torque detection level 2 (Torque Detection Level 2) 1.50
Torque detection time 2 (Torque Detection Time 2) 0.1
Forward torque limit (Forward Torque Limit)
Reverse torque limit (Reverse Torque Limit) 200
Forward regenerative torque limit (Forward Regenerative Torque Limit) 200
Reverse regenerative torque limit (Reverse Regenerative Torque Limit) 200
Protection selection for internal DB resistance (DB Resistance Protection Select) 0
Pre-overheat alarm level (Pre-Overheat Alarm Level) 95
Input open phase protection selection (Input Open Phase Protection Select) 0
Output open phase protection selection (Output Open Phase Protection Select) 0
Monitor selection (Monitor Size) 6
Monitor selection after power on (Power On Monitor)
STOP button function during control circuit terminal operation (Operational STOP Button) 1
kVA selection (Inverter Model #) 20
Operation selection when digital operator connection is disconnected (Operational Detection) 0